Circuit Specialists CSI-TC1 User Manual Download Page 1

 

多功能测试仪(

TC-V2.12k

 

Multi-function Tester (TC-V2.12k) 

 

2017-4-62015-8-8 

版权所有,侵权必究

All rights reserved 

14

,

25

Page 14 , Total25 

 

Multi-function Tester (TC-V2.12k) 

1

 

Overview 

1.1

 

Introduction 

 

① - 

160x128 TFT display 

② - 

Multi function key 

③ - 

Transistor test area 

④ - 

Zener Diode test area 

⑤ - 

IR receiver window 

⑥ - 

Micro USB Charging Interface 

⑦ - 

Charge indicator LED 

Summary of Contents for CSI-TC1

Page 1: ...8 8 All rights reserved 14 25 Page 14 Total25 Multi function Tester TC V2 12k 1 Overview 1 1 Introduction 160x128 TFT display Multi function key Transistor test area Zener Diode test area IR receiver...

Page 2: ...V Automatic detection of zener diode 0 01 30V Self test with automatic calibration IR decoder Support Hitachi IR coding IR waveform display Infrared receiving instruction Other Measurement results usi...

Page 3: ...the power off state or the test is completed put the test element into the transistor test area of test seat and press the locking handle short press the multifunction key the tester automatically mea...

Page 4: ...TC V2 12k Multi function Tester TC V2 12k 2017 4 62015 8 8 All rights reserved 17 25 Page 17 Total25 Battery BJT Bipolar Junction Transistor Diode...

Page 5: ...TC V2 12k Multi function Tester TC V2 12k 2017 4 62015 8 8 All rights reserved 18 25 Page 18 Total25 2 Diodes MOSFET...

Page 6: ...TC V2 12k Multi function Tester TC V2 12k 2017 4 62015 8 8 All rights reserved 19 25 Page 19 Total25 Thyristor Triac Capacitor Resistor...

Page 7: ...nductor 2 4 Selftest Short all three Probes short press the multifunction key the tester will be automatically calibrates itself In addition to the calibration process when prompted disconnect externa...

Page 8: ...n accuracy 2 5 Detect Zener diode In the power off state or the detection is completed put the Zener diode into the Zener diode test area of test seat and press the locking handle short press the mult...

Page 9: ...and data code The dot at the top right corner to indicate whether it has received the remote control infrared data red represents infrared data is being received blue represents decoding success Info...

Page 10: ...ement is included 2 8 Built in Li ion Battery voltage measurement The built in Li ion Battery voltage is measured before detection when the battery voltage is less than 3 0V will force shutdown then p...

Page 11: ...ea Forward Voltage Reverse Voltage 0 01 30V Zener Diode test area Reverse Voltage MOSFET JFET Cg Gate Capacitance Id Drain Current at Vgs Gate to Source Threshold Voltag Uf Forward Voltage of protecti...

Page 12: ...ective Note Measurement of inductors with resistance below 2100 4 FAQ Question Cause Solution Cannot power on Built in Li ion Battery is dead Charging the Li ion Battery charging methods see section 2...

Reviews: