* After using the rework station remember to allow the unit to cool down before turning it off.
* Never drop or sharply jolt the unit. The unit has in it quartz glass, which can break if the unit is
dropped or jolted.
* Do Not Disassemble the pump.
* Disconnect the unit when you are not using it for long periods of time.

5. REPLACING THE HEATING ELEMENT
5-1. Replacement Parts
Part# Name/Specification
A1144

110V/250W Heating Element

5-2. Replacing the heating element

Loosen the 3 screws in the handle. Then slide the hose down off of the base of the handle.
Open the Handle. Disconnect the ground wire sleeve, and remove the pipe, In the pipe is

were the quartz glass and heating element are installed. Do not drop or handle it harshly. Loosen
the electric cable and take out the heating element. Install the new heating element and reconnect
the electric cable. Reconnect the ground wire. Assemble the handle in the reverse order.

Trouble Shooting:

Q: Why is the unit so noisy when I first start it up?
A: The unit ships with a holding screw in the base of the unit. It must be removed.

Q: The unit vibrates to much.
A: The unit ships with a holding screw to help keep the pumps rubber shock supports from coming loose
during shipping, however sometimes the supports still come loose and need to be reset. With the unit
Unplugged remove the 6 screws 3 on each side and remove the cover. There are 4 rubber support legs that
should be pulled through the base. If any are not they need to be pulled threw firmly.

Q: When I start to adjust the airflow by pressing the up arrow the ball goes to half. when i press it again it
goes to full, and still when I press it again it drops down to zero.
A: The unit is okay. A calibrating adjustment may have been missed in the manufacturing process. By
pressing the air flow control up arrow further will allow you to control the air.

Q: The Unit will not heat up.
A: The units heating element may have been damaged in shipping or the controller board is defective.