10
www.imo.se
GA
0601.03 en-GB, ID-No.: 901930331, 161-490/A
Dismantling, replacement of components and
reassembly, GAD
626
609
605
608
601
451
Fig. 18
Fig. 19
Fig. 20
Fig. 21
• Remove the valve from the system. Use appropriate vessels to collect oil spillage when removing
and opening the valve.
• Remove the cap
626 and the nut
609 and unscrew
the set screw 608 a
few turns until you
see the O-ring 605.
Replace the O-ring
if necessary.
• Loosen and remove the screws 451. Re
-
move the valve cover 601 and collect the
valve assembly.
A.
B.
C.
D.
213
623
(for
T008)
615
(for T008)
612C
213
612C
615
(T040)
(T075)
(T100)
Fig. 22
E.
If you need another pressure range:
• Remove the retaining ring 213 with a pair
of pliers.
• Remove the spring washer 612C and the
stop washer 623 (for T008).
• Remove the spring 615.
• Mount the washers
according to fig. 7 at
page 7 or the T008
spring.
• Mount (the washer 623
if you mount the T008)
the spring washer
612C and the retaining
ring 213.
Spring size change, D+E