CAUTION
Never exceed equipment's minimum or maximum allowable fluid temperature. Do
not expose equipment to thermal shock. Differences in metallurgy and their
respective coefficients of expansion could cause distortion of pump parts resulting
in a breakdown condition.
G323FHFTX-630M Parts List
IDP Qty
Description
Kit
IDP
Qty
Description
Kit
1 1
Case
41
2
Outboard
Idlers
XX
2 2
Covers
42
1
Collar
3 1
Rear
Cover 43
1
Set
Screw(s)
5 2
Gaskets
X
44
1
Key
X
6 2
O-Rings
X
45
2
Bushings
X
9
12
Hex Cap Screws
46
1
Check Nut
10 2
Pipe
Plug
51
1
Tee
11 2
Housings
XX
52
1
Close
Nipple
12 2
Bracket
53
2
Tubing
Connectors
13 8
Cap
Screws
54
1
Tubing
15 16
Lock
Washers
55
2
Connectors
16
8
Hex Bolts
59
40
Hex bolts
17
2
Spring Pins
61
1
Set Screw (550J Only)
18 1
Shim
X
62
1
Pipe
Plug
19 1
Cover X
63
1
Seal
Housing
20 4
Capscrews
XX
64
1
Mechanical
Seal
X
21 4
Lock
Washers
67
1
Sleeve
34
1
Power Rotor
XX
68
8
Hex Nut
40
2
Inboard Idlers
XX
69
2
Set Screw
X =
Minor Repair Kit Items
XX =
Major Repair Kit Items (Items marked X are included in major repair kits.)
TABLE 1 – Parts List
ASSEMBLY AND DISASSEMBLY INSTRUCTIONS
Note:
Part numbers contained within parentheses such as (36) refer to balloon number as shown on
assembly drawing and IDP numbers in Table 1.
WARNING
Before starting any maintenance procedure:
Remove electrical service fuse, de-energize and lock the
electrical service panel supply to the driver.
Shut, wire or chain shut and lock all pump piping valves. If applicable,
shut off any steam supply lines to the pump and/or driver.
Note:
Depending on type of coupling installed (clearance between pump and driver shaft ends),
maintenance to mechanical seal can be performed without removal of pump driver. If
complete overhaul of pump is required, removing pump from its mounting and locating pump
in a suitable work area is recommended.
If seal only is to be serviced, follow steps 1 through 4 in disassembly procedure and steps 10 through 13 in
reassembly procedures.
If complete overhaul of pump is required, removal of pump from its mounting and locating the pump in a
suitable work area is recommended. It is also recommended that all gaskets and seal be replaced during
overhaul; regardless of their condition.