background image

 

7

 

                                     Figure 2                                                                       Figure 3 
             Elastomer Bellows Mechanical Seal                             Metal Bellows Mechanical Seal 

 

     

 

 
 

5.  Remove ball bearing (11) from power rotor (7) by first removing retaining ring (15) from groove in power rotor (7) 

shaft.  Ball bearing (11) can then be removed with a gear puller or arbor press. 

 

 

CAUTION

 

 

Removal of bearing by force applied to its outer ring could damage bearing.  

 
NOTE: 

Imo Pump strongly recommends replacing ball bearing every time it is removed from power rotor. 

 

6.  Remove inlet head (2) after first removing four bolts (3 or 6) from inlet head (2). 

 

7.  Remove O-ring (26 or 31, depending on pump size) from inlet head (2). 

 

H.4 – PUMP ASSEMBLY / REASSEMBLY 

 

NOTE:

  Prior to pump assembly, all parts should be cleaned and inspected for nicks, burrs or gouges. When 

ready for assembly, wipe all parts, including bolts, O-rings and seal faces with a clean, lubricating oil 
or pumped product, if applicable. 

 

 

CAUTION

 

 

Bearing service life could be significantly reduced if pushed onto shaft by outer ring. 

 

1.  Install ball bearing

 

(11)

 

onto shaft (7) using an arbor press and sleeve by pushing on ball bearing (11) inner ring 

only

 until ball bearing (11) is positioned against shoulder on power rotor (7). 

 

2.  Install retaining ring (15) in groove into power rotor (7). 

 

3.  Before installing seal (16), insure power rotor (7) shaft is clean and has no burrs or sharp edges.  

 

 

CAUTION

 

 

To avoid seal leaks, avoid contacting sealing faces of mechanical seal with any objects, including fingers.  
Objects can scratch sealing surfaces.  Acids in finger oils can etch them. 

 

4.  Mechanical Seal (16) Installation – See Figures 2 and 3 above. 

 

Clean and Lubricate Sealing Face – Clean sealing faces of rotating assembly and stationary seat with alcohol and 
lint free cloth.  Apply light film of clean lubricating oil to both sealing faces. 

 

ROTATING ASSEMBLY 

 Seals with Elastomer (rubber-like) Bellows – Apply light film of oil to elastomer bore of rotating assembly and 

push it onto power rotor (7) shaft with twisting motion.  Do not allow fingers to touch sealing face. 

 Seals with Metal Bellows – Apply light film of clean lubricating oil to O-ring in rotating assembly bore and push 

onto power rotor shaft (7) with a rotating motion. For size 20 only, make sure slots in rotating assembly line up 
with seal return hole in power rotor shaft (7). Tighten seal setscrew(s). 

Summary of Contents for IMO CFHN Series

Page 1: ...s manual AND the following CE compliant manuals should be read thoroughly and in their entirety prior to pump installation operation and maintenance Manual No SRM00100 Safety and Operation Manual Manu...

Page 2: ...tact with electrical equipment can cause shock Contact of electrical equipment with water can cause shock Do NOT touch with wet hands Always disconnect when not in use CONTENTS Cover Sheet 1 Safety an...

Page 3: ...overs only CFHN series pumps These pumps have been designed for general use in lubricating seal and distillate fuel oil applications Size and construction of each pump is identified in model number on...

Page 4: ...inlet pressure discharge pressure filtration duty cycle drive type mounting etc are interrelated Due to these variable conditions specific application limits may be different from that of operational...

Page 5: ...nt versions POS NO 6 Qty 6 on right angle inlet versions size 20 pumps POS NO 6 Qty 8 on right angle inlet versions of sizes 40 through 90 G INSPECTION Interval for inspection and replacement of worn...

Page 6: ...removed parts can be properly replaced CAUTION When removing inboard cover 4 from pump DO NOT pull out power rotor 7 and idler rotors 8 at same time since they may drop out and be damaged If rotors s...

Page 7: ...eve by pushing on ball bearing 11 inner ring only until ball bearing 11 is positioned against shoulder on power rotor 7 2 Install retaining ring 15 in groove into power rotor 7 3 Before installing sea...

Page 8: ...SHOOTING Install coupling to pump drive shaft Align pump and driver shafts per Manual SRM00101 Connect piping to pump Open inlet and outlet line valves Vent air from seal chamber before starting pump...

Page 9: ...9 Figure 4 CFHN020 Pumps...

Page 10: ...10 Figure 5 CFHN040 060 and 090 Pumps 10...

Page 11: ...VENT ORIENTATION NOT CRITICAL WITH VERTICAL MOUNTING 2 THESE PARTS FOR FOOT MOUNT OPTION ONLY INLET OUTLET SECTION A A 1 16 MAX 47 8 WEEP SEAL VENT 3 95 95 TORQUE TO 61 N M 7 N M 3 3 47 16 4 7 13 15 1...

Page 12: ...12 CIRCOR 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Email cc circor com Web www circorpt com 2021 CIRCOR Pumps North America LLC All rights reserved...