background image

 

5

 

F. PARTS LIST 

 

Part number identifiers (POSITION NUMBERS / POS. NO.’s) contained in Table 2 refer to circled numbers shown on 
assembly drawings, Figures 4, 5 and 6. 

 

Table 2 – Parts List 

 

POS. 

NO. 

QTY DESCRIPTION  

POS. 

NO. 

QTY DESCRIPTION 

Housing 

 

  15 X 

Retaining Ring 

Inlet Cover 

 

  16 X 

Seal 

0, 2, 4 or 8 

Bolt (See Note) 

 

20  

Bracket (Foot Mount Pumps Only) 

Inboard Cover 

 

21 

Bolts for Foot Bracket 

4,6 or 8 

Bolt (See Note) 

 

  26 X 

O-Ring (size 40 to 90) 

Power Rotor  

 

  31 X 

O-Ring (Qty 2 on size 20 Pumps) 

8 2 

Idler 

Rotor   47 

Plug 

11 

   1 X 

Ball Bearing 

 

95 

Pin 

13 1 

Key 

    

 

X = Minor Repair Kit Item 

 

Note:

 

POS. NO.  3: 

Qty 4 on axial inlet versions of all pump sizes 20 through 330. 

 

POS. NO.  3: 

Qty 2 on right angle inlet versions of size 20 pumps. 

 

POS. NO.  3: 

Qty 0 on right angle inlet versions of size 40 through 90 pumps. 

 

POS. NO.  3: 

Qty 8 on right angle inlet versions of size 140 through 330 pumps (Qty 12 

 

 

on Foot Mount versions) 

 

POS. NO.  6: 

Qty 6 on right angle inlet versions size 20 pumps. 

 

POS. NO.  6: 

Qty 8 on right angle inlet versions of sizes 40 through 90. 

 

 

G. INSPECTION 

 

Interval for inspection and replacement of worn parts varies with properties of pumped liquid and can only be 
determined by experience. A worn pump will be noticeable by excessive vibration, noise, reduction in flow output 
and/or reduction in system pressure. 

 

 

CAUTION

 

 

All CFHN Series internal pump parts, including ball bearing, are lubricated by pumped liquid.  Pumping a liquid 
which contains abrasive materials, that is too low in viscosity or lubricity, or that is corrosive, will significantly 
reduce service life and call for shorter service intervals. 

 
 

H. PUMP MAINTENANCE 

 

 

 

WARNING

 

 

Failure to observe precautions while installing, inspecting, and maintaining the pump can cause injury to 
personnel from accidental handling, e.g.: Liquids that may harm skin or clothing, fire hazard risks from flammable 
liquids, or injury from high pressure fluid jets. 

 

   

 

 

DANGER

 

 

BEFORE

 working on equipment, be sure all power to the equipment is disconnected and locked-out. 

 

Summary of Contents for IMO CFHN Series

Page 1: ...s manual AND the following CE compliant manuals should be read thoroughly and in their entirety prior to pump installation operation and maintenance Manual No SRM00100 Safety and Operation Manual Manu...

Page 2: ...tact with electrical equipment can cause shock Contact of electrical equipment with water can cause shock Do NOT touch with wet hands Always disconnect when not in use CONTENTS Cover Sheet 1 Safety an...

Page 3: ...overs only CFHN series pumps These pumps have been designed for general use in lubricating seal and distillate fuel oil applications Size and construction of each pump is identified in model number on...

Page 4: ...inlet pressure discharge pressure filtration duty cycle drive type mounting etc are interrelated Due to these variable conditions specific application limits may be different from that of operational...

Page 5: ...nt versions POS NO 6 Qty 6 on right angle inlet versions size 20 pumps POS NO 6 Qty 8 on right angle inlet versions of sizes 40 through 90 G INSPECTION Interval for inspection and replacement of worn...

Page 6: ...removed parts can be properly replaced CAUTION When removing inboard cover 4 from pump DO NOT pull out power rotor 7 and idler rotors 8 at same time since they may drop out and be damaged If rotors s...

Page 7: ...eve by pushing on ball bearing 11 inner ring only until ball bearing 11 is positioned against shoulder on power rotor 7 2 Install retaining ring 15 in groove into power rotor 7 3 Before installing sea...

Page 8: ...SHOOTING Install coupling to pump drive shaft Align pump and driver shafts per Manual SRM00101 Connect piping to pump Open inlet and outlet line valves Vent air from seal chamber before starting pump...

Page 9: ...9 Figure 4 CFHN020 Pumps...

Page 10: ...10 Figure 5 CFHN040 060 and 090 Pumps 10...

Page 11: ...VENT ORIENTATION NOT CRITICAL WITH VERTICAL MOUNTING 2 THESE PARTS FOR FOOT MOUNT OPTION ONLY INLET OUTLET SECTION A A 1 16 MAX 47 8 WEEP SEAL VENT 3 95 95 TORQUE TO 61 N M 7 N M 3 3 47 16 4 7 13 15 1...

Page 12: ...12 CIRCOR 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Email cc circor com Web www circorpt com 2021 CIRCOR Pumps North America LLC All rights reserved...

Reviews: