IMPORTANT NOTE 

 

The importance of seal chamber priming cannot be overemphasized.  Due to the 
prevalence of seal damage and leakage caused by not filling the seal chamber with 
liquid before putting a pump in service, this page is located at the beginning of this 
document. 

 

SEAL CHAMBER PRIMING 

 

Fill mechanical seal chamber with liquid to insure seal does not start dry. This can be done by removing 
seal vent set-screw and pouring liquid into vent passageway before opening pump inlet. Alternately, 
seal chamber can be vented in situations where inlet pressure is above atmospheric by opening inlet and 
discharge valves and then loosening seal vent plug to allow positive inlet pressure to push air out of seal 
chamber until oil flows from it. 

See figure below. 

 
 

 

 

 Filling or Venting Seal Cavity Using Seal Vent  

 
 
 

 

 

CAUTION

 

 

Failure to fill or vent seal chamber as described above may cause damage to seal running 
faces which may result in seal leakage.

   

 

Summary of Contents for G3D**-350 Series

Page 1: ...The Imo General Installation Operation Maintenance and Troubleshooting Manual No SRM00046 as well as all other component manuals supplied with these type units should be read thoroughly prior to pump...

Page 2: ...s can be done by removing seal vent set screw and pouring liquid into vent passageway before opening pump inlet Alternately seal chamber can be vented in situations where inlet pressure is above atmos...

Page 3: ...ns where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of pump and or protection of pump itself are marked by the sign ATT...

Page 4: ...y this manual In applications where equipment furnished by Imo Pump is to become part of processing machinery these instructions should be thoroughly reviewed to ensure proper fit of said equipment in...

Page 5: ...tor T Carbide Seat X Special Material Or Construction 3rd Letter Designator S Steel casing T Carbide Seat X Special Material Or Construction 2nd Letter Designator C Circular Mounting Flange H Special...

Page 6: ...er no circumstances are the following operating limits specified in table 1 to be exceeded without specific approval from Imo Pump Table 1 Normal Pump Operating and Structural Limits Condition Limit M...

Page 7: ...C Face Only 10 16 Hex Bolts 36 1 Pipe Coupling C Face Only 11 1 Power Rotor XX 37 1 Tube Fitting C Face Only 13 2 Snap Rings X 38 1 Seal Spacer 14 1 Spacer Seal Seat Adapter X 42 1 Tubing C Face Only...

Page 8: ...1 Power Rotor Balance Piston C Face Only XX 30 16 Washers 8 on C Face 79 2 90 Tube Fitting C Face Only 31 1 Key 88 1 Inlet O ring Axial inlet pumps only X 38 1 Seal Spacer 95 8 Nuts C Face only 42 2...

Page 9: ...and key 16 or 31 2 Remove bearing retainer 17 or 43 from inboard cover 9 or 46 by removing bolts 18 or 47 and lockwashers 30 if present 3 Remove assembled power rotor 11 or 63 from inboard cover 9 or...

Page 10: ...equire heating to loosen Loctite before bushing 33 or 86 can be removed Do not heat to more than 250 F 9 Remove inlet head 26 or 2 from case 1 by removing bolts 10 or 54 and lockwashers 92 or 30 if pr...

Page 11: ...ivalent onto the mating surfaces of bushing 33 or 86 and inboard cover 9 or 46 Allow 1 to 5 minutes until primer is visibly dry Apply Locitite 609 or equivalent to bushing 33 or 86 and inboard cover 9...

Page 12: ...t of clean system fluid or light oil on seal running face Install the rotating ring running face against the stationary seat face f Install inner snap ring 13 or 42 in groove of power rotor 11 or 63 g...

Page 13: ...4 and lockwashers 92 or 30 if present Torque bolts to value on correct assembly drawing NOTE Inlet head 26 or 2 can be rotated and repositioned in 90 degree increments to suit suction piping To change...

Page 14: ...ctory overhaul assistance contact your local Imo Sales Office or representative at Technical Customer Service Department in Monroe NC USA Most pumps have repair kits available Minor Repair Kits are us...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...OR International all rights reserved CIRCOR Pumps North America LLC 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 704 289 6511 Toll 1 877 853 7867 Email cc colfaxfluidhandling com Web c...

Reviews: