SAFETY PRECAUTIONS
SAFETY PRECAUTIONS
Grounding Instructions
Grounding Instructions
This treadmill must be grounded. If it should malfunction or break down, grounding provides
a path of least resistance for electric current to reduce the risk of electric shock.
This product is equipped with a cord having an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Please make sure that the treadmill is connected to an outlet having the same configuration as the
plug. Do not use a ground plug adapter to adapt the power cord to a non-grounded outlet.
115V EURO PLUG 208-220V
NEMA 5-20 CEE 7/7 NEMA 6-15
The power requirements for the treadmill include a grounded, dedicated circuit, rated for one of the
following:
115 VAC 5%, 60HZ and 20 amps; 208/220 VAC, 60HZ, 15 amps or 230 VAC 5%, 50HZ and
15amps.
GROUNDING OUTLET
GROUNDING OUTLET
TREADMILL POWER CORD
SURGE PROTECTOR
GROUNDING PLUG
ADAPTOR
SCREW
SURGE PROTECTOR
GROUNDING PLUG
3 PRONG OUTLET
2 PRONG OUTLET
4