background image

EGS3

Version:

01.000a

DocId:

EGS3_HD_v01.000a

Hardware Interface Description

Summary of Contents for EGS3

Page 1: ...EGS3 Version 01 000a DocId EGS3_HD_v01 000a Hardware Interface Description...

Page 2: ...ERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT THIS GENERAL NOTE SHALL BE GOV ERNED AND CONSTRUED ACCORDING TO GERMAN...

Page 3: ...27 3 3 1 Turn on EGS3 27 3 3 1 1 Turn on EGS3 Using Ignition Line IGT 27 3 3 1 2 Configuring the IGT Line for Use as ON OFF Switch 30 3 3 1 3 Turn on EGS3 Using the VCHARGE Signal 30 3 3 1 4 Reset EGS...

Page 4: ...2 2 Differential Microphone Input 61 3 14 2 3 Line Input Configuration with OpAmp 62 3 14 3 Loudspeaker Circuit 63 3 14 4 Digital Audio Interface DAI 63 3 14 4 1 Master Mode 65 3 14 4 2 Slave Mode 66...

Page 5: ...3 6 2 3 Soldering Conditions and Temperature 103 6 2 3 1 Reflow Profile 103 6 2 3 2 Maximum Temperature and Duration 104 6 2 4 Durability and Mechanical Handling 105 6 2 4 1 Storage Life 105 6 2 4 2 P...

Page 6: ...of ASC1 53 Table 17 Configuration combinations for the PCM interface 64 Table 18 Overview of DAI signal functions 64 Table 19 Return loss in the active band 71 Table 20 Absolute maximum ratings 75 Ta...

Page 7: ...microphone input 60 Figure 22 Differential microphone input 61 Figure 23 Line input configuration with OpAmp 62 Figure 24 Differential loudspeaker configuration 63 Figure 25 Master PCM interface Appl...

Page 8: ...EGS3 Hardware Interface Description Figures 8 EGS3_HD_v01 000a Page 8 of 117 2009 08 12 Confidential Released Figure 51 EGS3 sample application 112 Figure 52 Reference equipment for Type Approval 113...

Page 9: ...3 3 1 1 Removed URC Shutdown after Illegal Powerup 3 3 2 Table 8 Changed values of PU Pull up typ 200 A and max 350 A 3 9 Added remark on bit rate tolerance for autobauding 5 2 Table 22 Removed line...

Page 10: ...te 24 Application Developer s Guide 9 Application Note 26 Power Supply Design for Wireless Applications 10 Application Note 32 Integrating USB into GSM Applications 11 Application Note 48 SMT Module I...

Page 11: ...uipment typically computer terminal printer or for example GSM application DTR Data Terminal Ready DTX Discontinuous Transmission EFR Enhanced Full Rate EGSM Enhanced GSM EIRP Equivalent Isotropic Rad...

Page 12: ...BCCH Packet Switched Broadcast Control Channel PCB Printed Circuit Board PCL Power Control Level PCM Pulse Code Modulation PCN Personal Communications Network also referred to as DCS 1800 PCS Personal...

Page 13: ...ace Mount Technology SPI Serial Peripheral Interface SRAM Static Random Access Memory TA Terminal adapter e g GSM module TDMA Time Division Multiple Access TE Terminal Equipment also referred to as DT...

Page 14: ...nuary 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equip ment RoHS Table 2 Standards of North American type approval CFR Title 47 Code of Federal Reg...

Page 15: ...f Information Industry of the People s Republic of China SJ T 11363 2006 Requirements for Concentration Limits for Certain Hazardous Sub stances in Electronic Information Products 2006 06 SJ T 11364 2...

Page 16: ...nce the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use For European and US markets the re...

Page 17: ...the suspension or denial of cellular services to the offender legal action or both Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes Switch off the cellular t...

Page 18: ...ply 3 2V to 4 5V Ambient operating temperature according to IEC 60068 2 Normal operation 30 C to 75 C Restricted operation 75 C to 85 C 30 C to 40 C Physical Dimensions 29 6mm x 33 9mm x 3 2mm Weight...

Page 19: ...ssibility to use an optional module mounting socket For more information on how to integrate SMT modules see also 11 This application note comprises chapters on module mounting and application layout...

Page 20: ...AT SMSO Automatic switch off in case of critical temperature and voltage conditions Reset Orderly shutdown and reset by AT command Emergency reset by hardware signals EMERG_OFF and IGT Special featur...

Page 21: ...EGS3 Hardware Interface Description 2 2 EGS3 System Overview 22 EGS3_HD_v01 000a Page 21 of 117 2009 08 12 Confidential Released 2 2 EGS3 System Overview Figure 1 EGS3 system overview...

Page 22: ...nterface SMT with connecting pads RF section RF transceiver RF power amplifier RF front Antenna pad Figure 2 EGS3 block diagram BATT GND IGT EMERG_OFF ASC 0 SIM Interface D 0 15 A 0 24 RD WR CS WAIT I...

Page 23: ...tes several sub interfaces described in the following sections Power supply see Section 3 2 Charger interface see Section 3 5 SIM interface see Section 3 8 Serial interface ASC0 see Section 3 9 Serial...

Page 24: ...progress Power consumption depends on network settings e g power control level uplink downlink data rates GPRS configuration e g used multislot settings and reduction of maximum output power POWER DO...

Page 25: ...XT line a regulated voltage for an external application This voltage is not available in Power down mode SIM switch to provide SIM power supply 3 2 1 Minimizing Power Losses When designing the power s...

Page 26: ...ure 4 Figure 4 Position of reference points BATT and GND 3 2 3 Monitoring Power Supply by AT Command To monitor the supply voltage you can also use the AT SBV command which returns the value related t...

Page 27: ...te the module s ready state SYSSTART indicates that the module has entered Normal mode SYSSTART AIRPLANE MODE indicates that the module has entered Airplane mode SYSSTART CHARGE ONLY MODE indicates th...

Page 28: ...enabled To allow the application to detect the ready state of the module we recommend using hardware flow control which can be set with AT Q or AT IFC see 1 for details The default setting of EGS3 is...

Page 29: ...Scenarios 70 EGS3_HD_v01 000a Page 29 of 117 2009 08 12 Confidential Released Figure 6 Powerup with IGT held low before switching on operating voltage at BATT For details on how to use EMERG_OFF to r...

Page 30: ...e EGS3 is on the IGT line must be asserted for at least 1s before being released The module switches off after the line is released The switch off routine is identical with the procedure initiated by...

Page 31: ...in the volatile memory Therefore this procedure is intended only for use in case of emergency e g if EGS3 does not respond if reset or shutdown via AT command fails The EMERG_OFF signal is available...

Page 32: ...gain once the respective interface is activated or configured by AT command Table 8 Signal states Signal name Undefined state during startup Defined state after startup ini tialization Active state af...

Page 33: ...he signal has the intermediate states O H for about 2s and O L for about 1s 3 Before reaching the defined state the signal has the intermediate state O H for about 0 5s L Low level H High level L H Lo...

Page 34: ...llowing response SMSO MS OFF OK SHUTDOWN After sending AT SMSO do not enter any other AT commands There are two ways to verify when the module turns off Wait for the URC SHUTDOWN It indicates that dat...

Page 35: ...Description 3 3 Power Up Power Down Scenarios 70 EGS3_HD_v01 000a Page 35 of 117 2009 08 12 Confidential Released Figure 8 Signal states during turn off procedure Note 1 Depending on capacitance load...

Page 36: ...t application or Terminal program on the USB VCOM port be closed down before the module restarts Note that if AT CFUN x 1 is entered on the USB interface the application or Terminal program on the USB...

Page 37: ...ated URCs indicating the level 2 or 2 are instantly followed by an orderly shutdown except in cases described in Section 3 3 4 2 The presentation of these URCs is always enabled i e they will be outpu...

Page 38: ...to prevent damage to the module Extended usage of the deferred shutdown functionality may result in damage to the module and possibly other severe consequences 3 3 4 3 Undervoltage Shutdown If the mea...

Page 39: ...BC Overvoltage warning This alert is sent once When the overvoltage shutdown threshold is exceeded the module will send the following URC SBC Overvoltage shutdown before it shuts down cleanly This typ...

Page 40: ...ops by 5 degrees EGS3 returns to the higher Multislot Class If the temperature stays at the critical level or even continues to rise EGS3 will not switch back to the higher class After a transition fr...

Page 41: ...n your application according to the Figure 51 3 5 2 Software Requirements Use the command AT SBC parameter current to enter the current consumption of the host application This information enables the...

Page 42: ...arging process will not start if no NTC is present Ensure that the pack incorporates a protection circuit capable of detecting overvoltage pro tection against overcharging undervoltage protection agai...

Page 43: ...for use with electronic applications like mobile phones PDAs MP3 players security and telematic devices It has almost the same properties as the above Li Ion battery It is type Polymer is smaller lig...

Page 44: ...V the battery is charged at 100mA Software controlled charging Controlled over CHARGEGATE Temperature conditions 0 C to 45 C Software controlled charging is done when the charger is present connected...

Page 45: ...or undertemperature In these cases you can only switch the module off by disconnecting the charger To proceed from Charge only mode to another operating mode you have the following options provided t...

Page 46: ...power level PCL5 and GPRS Class 12 at the same time the current consumption is higher than the current supplied by the charger Charge only mode Connect charger to charger input of host application ch...

Page 47: ...e both the EGS3 and the application must be configured to use hard ware flow control This is necessary since the CTSx signal is set reset every 0 9 2 7 seconds in order to indicate to the application...

Page 48: ...up the ME In this case the activity time is at least the time set with AT SCFG PowerSaver Mode9 Time out psm9to default 2 seconds RTSx has to be asserted for at least a dedicated debounce time in ord...

Page 49: ...f AT SCFG MeOpMode Airplane OnStart off IGT 400 ms at low level then release IGT Connect charger to VCHARGE If AT SCFG MeOpMode Airplane OnStart on IGT 400 ms at low level then release IGT Regardless...

Page 50: ...to meet the specifications of 3GPP TS 51 010 1 and to satisfy the requirements of EMC compliance To avoid possible cross talk from the CCCLK signal to the CCIO signal be careful that both lines are n...

Page 51: ...he GSM module with AT commands Full Multiplex capability allows the interface to be partitioned into three virtual channels yet with CSD and fax services only available on the first logical channel Pl...

Page 52: ...d Table 15 DCE DTE wiring of ASC0 V 24 circuit DCE DTE Line function Signal direction Line function Signal direction 103 TXD0 Input TXD Output 104 RXD0 Output RXD Input 105 RTS0 Input RTS Output 106 C...

Page 53: ...D application sends data to module s TXD1 signal line Port RXD application receives data from the module s RXD1 signal line Figure 14 Serial interface ASC1 Features Includes only the data lines TXD1 a...

Page 54: ...across the VUSB_IN line power to the module s USB interface but not to other EGS3 interfaces This is because EGS3 is designed as a self powered device compliant with the Universal Serial Bus Specific...

Page 55: ...vation of the SPI locks both lines for I2 C Detailed information on the AT SSPI command as well explana tions on the protocol and syntax required for data transmission can be found in 1 The I2 C inter...

Page 56: ...ed and data can be transferred from the module and vice versa The SPI interface uses two independent lines for data input SPIDI and data output SPIDO Figure 18 SPI interface To configure and activate...

Page 57: ...EGS3 Hardware Interface Description 3 13 SPI Interface 70 EGS3_HD_v01 000a Page 57 of 117 2009 08 12 Confidential Released Figure 19 Characteristics of SPI modes...

Page 58: ...istics of the voiceband part vary with the audio mode For example sending and receiving amplification sidetone paths noise suppression etc depend on the selected mode and can be altered with AT comman...

Page 59: ...voltage supply VMIC and the dedicated audio ground line AGND Both lines are well suited to feed a balanced audio application or a single ended audio appli cation The AGND line on the EGS3 board is esp...

Page 60: ...sed to the MICPx DC level It is AC coupled via CK to a resistive divider which is used to optimize supply noise cancellation by the differential micro phone amplifier in the module The VMIC voltage sh...

Page 61: ...ched on Only if VMIC is switched on can the voltage applied to any MIC line be in the range of 2 4V to 0V If these limits are exceeded undervoltage shutdown may be caused Consider that the maximum ful...

Page 62: ...ed if gains larger than 20dB are used The filter can be at tached as a simple first order RC network RVMIC and CF If a high input level and a lower gain are applied the filter is not necessary Conside...

Page 63: ...face DAI The DAI can be used to connect audio devices capable of PCM Pulse Code Modulation or for type approval The following chapters describe the PCM interface functionality The PCM functionality al...

Page 64: ...es TXDAI and RXDAI however are used in both modes Unused inputs should be tied to GND via pull down resistors In addition DAI1 requires a 47kOhm pull down resistor to be placed as close as possible to...

Page 65: ...nsmission starts if short frame is configured If long frame is selected the frame sync signal FS is high during the whole transfer of the 16 data bits Each frame has a duration of 125 s and contains 3...

Page 66: ...nsfer starts at the falling edge of FSIN if the short frame format is selected and at the rising edge of FSIN if long frame format is selected With this edge control the frame sync signal is independe...

Page 67: ...ed Figure 28 Slave PCM interface application The following figures show the slave short and long frame timings Because these are edge controlled frame sync signals may deviate from the ideally form as...

Page 68: ...ection 3 15 2 The first function factory default AT SSYNC 0 is recommended if you want your application to use the synchronization signal for better power supply control Your platform design must be s...

Page 69: ...D must be connected to the host application The connected LED can be operated in two different display modes AT SSYNC 1 or AT SSYNC 2 For details please refer to 1 Figure 32 LED Circuit Example Especi...

Page 70: ...t the expense of a higher current consumption Therefore utilizing the RING0 line provides an option to significantly reduce the overall current consumption of your application The behavior of the RING...

Page 71: ...Installation The antenna is connected by soldering the antenna pad RF_OUT i e pad 96 and its neigh boring ground pads GND i e pads 81 and 119 directly to the application s PCB Figure 35 Antenna pads T...

Page 72: ...For type approval purposes the module can be equipped with an optional coaxial antenna con nector U FL R SMT along with other necessary components The U FL R SMT connector has been chosen as antenna r...

Page 73: ...by the EGS3 module i e the trans mission line to the antenna connector as shown in Figure 37 Within the area populated by the EGS3 module the RF line width shall be reduced to 700 m and the distance t...

Page 74: ...EGS3 Hardware Interface Description 4 2 RF Line Routing Design 74 EGS3_HD_v01 000a Page 74 of 117 2009 08 12 Confidential Released Figure 37 RF line on interface board All dimensions are given in mm...

Page 75: ...Unit Peak current of power supply 1 6 A Supply voltage BATT 0 3 4 9 V Voltage at digital lines in POWER DOWN mode 0 3 0 3 V Voltage at digital lines in normal operation 0 3 3 05 or VEXT 0 3 V Voltage...

Page 76: ...own is deferred until hang up 30 to 40 80 to 90 C Automatic shutdown2 Temperature measured on EGS3 board Temperature measured at battery NTC 2 Due to temperature measurement uncertainty a tolerance on...

Page 77: ...idity relative Low High 10 90 at 40 C IPC JEDEC J STD 033A Air pressure Low High 70 106 kPa IEC TR 60271 3 1 1K4 IEC TR 60271 3 1 1K4 Movement of surrounding air 1 0 m s IEC TR 60271 3 1 1K4 Water rai...

Page 78: ...0Hz the Standard s acceleration reference value was increased to 20g Shock half sinus Acceleration 500g Shock duration 1msec 1 shock per axis 6 positions x y and z DIN IEC 68 2 27 Dry heat Temperature...

Page 79: ...lists the pads assignments Figure 38 Numbering plan for connecting pads bottom view 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 41 42 43 37 38 39...

Page 80: ...SPIDO 53 I2CCLK_SPICLK 93 GND 14 IGT 54 Do not use 94 GND 15 RXD0 55 EPN1 95 GND 16 CCIN 56 MICN1 96 RF_OUT 17 CCCLK 57 Do not use 97 GND 18 DAI6 58 Do not use 98 GND 19 DAI5 59 SPIDI 99 GND 20 Do not...

Page 81: ...g drop rip ple spikes Power supply GND Ground Application Ground Charge Interface VCHARGE I VImin 3 1V VImax 7 00V This line signalizes to the pro cessor that the charger is con nected If unused keep...

Page 82: ...or that needs to be connected to an external pull up resistor Low state of the open collector indi cates that the module is on Vice versa high level notifies the Power down mode Therefore the line may...

Page 83: ...Only effective for approximately 220ms during the assertion of IGT when the module is about to start Syn chroni zation SYNC O VOLmax 0 3V at I 0 1mA VOHmin 2 3V at I 0 1mA VOHmax 3 00V n Tx n x 577 s...

Page 84: ...100k VILmax 0 6V at I 25 A VIHmin 2 1V at I 10 A VOmax 3 05V CCIN Low SIM card holder closed Maximum cable length or cop per track 100mm to SIM card holder All signals of SIM interface are protected a...

Page 85: ...OLmax 0 3V at I 1mA VOHmin 1 45V at I 0 5mA VOHmax 1 90V CCVCC O VOmin 1 70V VOtyp 1 80V VOmax 1 90V IOmax 20mA CCGND Ground I2 C inter face I2CCLK_SPIC LK O VOLmax 0 2V at I 2mA VOHmin 2 55V at I 0 5...

Page 86: ...utput Crossover volt age Range VCRSmin 1 5V VCRSmax 2 0V Line to GND VOHmax 3 6V VOHtyp 3 2V VOHmin 3 0V at I 0 5mA VOLmax 0 2V at I 2mA VIHmin 2 24V VILmax 0 96V Driver Output Resistance Ztyp 32Ohm P...

Page 87: ...nimum differential load 7 5Ohms The audio output can directly operate an 8 Ohm loud speaker If unused keep lines open EPN1 O MICP1 I Full Scale Input Voltage 1 6 Vpp 0dBm0 Input Voltage 1 1 Vpp At MIC...

Page 88: ...V Voltage drop during transmit burst Normal condition power control level for Pout max 400 mV Voltage ripple Normal condition power control level for Pout max f 200kHz f 200kHz 50 2 mV mV IBATT OFF S...

Page 89: ...ss 12 Timeslot configuration 1Tx 1Rx 1Tx 4Rx 2Tx 3Rx 4Tx 1Rx RF power nominal 2W 33dBm 2W 33dBm 2W 33dBm 1W 30dBm 1W 30dBm 0 5W 27dBm Radio output power reduction with AT SCFG parameter ropr ropr 1 3...

Page 90: ...ass 12 Timeslot configuration 1Tx 1Rx 1Tx 4Rx 2Tx 3Rx 4Tx 1Rx RF power nominal 1W 30dBm 1W 30dBm 1W 30dBm 0 5W 27dBm 0 5W 27dBm 0 25W 24dBm Radio output power reduction with AT SCFG parameter ropr rop...

Page 91: ...parameters adjustable by AT commands Parameter Influence to Range Gain range Calculation inBbcGain MICP MICN analogue amplifier gain of baseband controller before ADC 0 7 0 42dB 6dB steps inCalibrate...

Page 92: ...2009 08 12 Confidential Released 5 7 2 Audio Programming Model The audio programming model shows how the signal path can be influenced by varying the AT command parameters The parameters inBbcGain an...

Page 93: ...individual handset Direct access to speech coder Direct access to speech coder Gain setting via AT command Defaults inBbcGain outBbcGain Fix 5 2 Adjustable 2 2 Adjustable 5 1 Adjustable 5 2 Adjustable...

Page 94: ...differential output voltage peak to peak EPP2 to EPN2 4 0 4 2 V V 32 no load Volume 32 3 14 dBm0 Full Scale Nominal differential out put voltage peak to peak EPP1 to EPN1 4 2 4 3 V V 8 no load Volume...

Page 95: ...will lead to clipping if the default gain is used 3 The idle channel noise was measured with digital zero signal fed to decoder This can be realized by setting outCalibrate and sideTone to 0 during a...

Page 96: ...nput voltage peak to peak for 0dBm0 MICP1 to MICN1 or AGND MICP2 to MICN2 or AGND 1 1 V MICPx must be biased with 1 25V VMIC 2 Input amplifier gain in 6dB steps inBbcGain 0 42 dB Set with AT SNFI Fine...

Page 97: ...S MS GSM 850 869 894 MHz E GSM 900 925 960 MHz GSM 1800 1805 1880 MHz GSM 1900 1930 1990 MHz RF power ARP with 50 load GSM 850 31 33 35 dBm E GSM 9001 1 Power control level PCL 5 31 33 35 dBm GSM 1800...

Page 98: ...ing ports of EGS3 are not accessible to the user of the final product since they are installed within the device and therefore are only protected according to the Human Body Model requirements EGS3 ha...

Page 99: ...v01 000a Page 99 of 117 2009 08 12 Confidential Released 6 Mechanics Mounting and Packaging 6 1 Mechanical Dimensions of EGS3 Figure 40 shows the top view of EGS3 and provides an overview of the board...

Page 100: ...EGS3 Hardware Interface Description 6 1 Mechanical Dimensions of EGS3 100 EGS3_HD_v01 000a Page 100 of 117 2009 08 12 Confidential Released Figure 41 Dimensions of EGS3 all dimensions in mm...

Page 101: ...t all pads denoted as Do not use will also have to be soldered but not electrically connected in order to ensure the best possible me chanical stability 6 2 1 SMT PCB Assembly 6 2 1 1 Land Pattern and...

Page 102: ...nd temperature cycling Sample surface mount checks are described in 11 It is recommended to characterize land patterns before an actual PCB production taking indi vidual processes materials equipment...

Page 103: ...t are susceptible to damage induced by absorbed moisture Cinterion s EGS3 module complies with the latest revision of the IPC JEDEC J STD 020 Stan dard for moisture sensitive surface mount devices and...

Page 104: ...eflow should generally be followed the limits listed above must not be exceeded EGS3 is specified for one soldering cycle only Once EGS3 is removed from the application the module will very likely be...

Page 105: ...anufacturing site processing the modules should have ambient temperatures below 30 C and a relative humidity below 60 6 2 4 3 Baking Baking conditions are specified on the moisture sensitivity label a...

Page 106: ...for EGS3 is illustrated in Figure 45 The figure also shows the prop er part orientation The tape width is 56 mm and the EGS3 modules are placed on the tape with a 36 mm pitch The reels are 330mm in d...

Page 107: ...ng 110 EGS3_HD_v01 000a Page 107 of 117 2009 08 12 Confidential Released 6 3 1 2 Barcode Label A barcode label provides detailed information on the tape and its contents It is attached to the reel Fig...

Page 108: ...els are stored inside an MBB moisture barrier bag together with a humidity indi cator card and desiccant pouches see Figure 48 The bag is ESD protected and delimits mois ture transmission It is vacuum...

Page 109: ...EGS3 Hardware Interface Description 6 3 Packaging 110 EGS3_HD_v01 000a Page 109 of 117 2009 08 12 Confidential Released Figure 49 Moisture Sensitivity Label...

Page 110: ...ed from the MBB The humidity indicator card is a moisture indicator and is included in the MBB to show the ap proximate relative humidity level within the bag Sample humidity cards are shown in Figure...

Page 111: ...oth lines for I2C Settings for either interface are made by using the AT SSPI command The internal pull up resistors Rp of the I2C interface can be connected to an external power supply or to the VEXT...

Page 112: ...ST CCIN CCVCC 200nF AGND EPN1 EPP1 EPP2 EPN2 Digital Audio 7 BC847 BC847 SYNC CRS04 1nF 10pF V up to 7 0V charge Sample Application 1 8 3 4 2 2 x RP 2 1 For debug and or test purposes test points will...

Page 113: ...nt Support Box DSB75 SIM card reader integrated on DSB75 U FL R SMT antenna connector and U FL LP antenna cable Handset type Votronic HH SI 30 3 V1 1 0 Li Ion battery capacity 1200mAh PC as MMI Figure...

Page 114: ...ipment The EGS3 reference application registered under the above identifiers is certified to be in ac cordance with the following Rules and Regulations of the Federal Communications Commis sion FCC an...

Page 115: ...is Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada If the final product is not approved for use in U S territori...

Page 116: ...rdering number L30960 N1555 A100 DSB75 Evaluation Kit Cinterion Ordering number L36880 N8811 A100 Votronic Handset VOTRONIC Votronic HH SI 30 3 V1 1 0 VOTRONIC Entwicklungs und Produktionsgesellschaft...

Page 117: ...ong Singapore Phone 65 268 6868 Fax 65 265 6044 Molex Japan Co Ltd Yamato Kanagawa Japan Phone 81 462 65 2324 Fax 81 462 65 2366 Table 40 Hirose sales contacts subject to change Hirose Ltd For further...

Reviews: