background image

 

Indicators 

The 

main indicator

 is placed in the top right corner and contains three 

symbols: 

 

 

blinking cross

 indicates self-motion of the radar 

or that the radar is calibrating.   

 

 

 

OK

 – indicates that the radar is active and that no 

movement has been detected 

 

 

The 

motion symbol 

indicates that movement has 

been detected 

 

When a movement occurs,

 the CPR4 may also show more detailed 

information about the motion itself – if possible. The information given is 

place

 

– 

direction

 – 

speed

. This is represented by three sets of symbols: 

 

Tree symbols – 

indicates whether the movement is detected close to the 

CPR4 or far away. The scale ranges from 1-4 trees. If

 

one

 

tree is shown, 

then the movement is close to the operator (typically less than 2m) and 

if 

four

 

trees are shown, then the movement is far away from the 

operator (typically more than 5m). 

 

Arrows –

 an UP arrow indicates that the detected object is 

moving

 

away

 

from the operator and a DOWN arrow indicates object is 

moving

 

towards

 the operator. 

 

Standing and walking man –

 indicates whether the detected object is 

standing 

relatively still

 or if it is 

moving. 

 

 

Summary of Contents for CPR4

Page 1: ...CPR4 Handheld Radar User manual...

Page 2: ...hen a movement occurs 6 Menu 1 Everyday use 8 Menu 2 Advanced settings 9 Battery change 10 Mounting support 10 CPR4 hard case 10 3 USING THE SOFTWARE 11 See what your CPR4 is seeing on your PC or Andr...

Page 3: ...ation We also recommend you to store your user manual in the enclosed hard case or in a safe place Before starting up we would like to give you some background information about our product The power...

Page 4: ...rfaces it hits The energy also penetrates all kind of materials except a homogenous metal plate Eventually some of the energy returns back to the radar The returned frequency is the same as the transm...

Page 5: ...and switching off the device The LAMP button us used for turning on and off the background lighting Starting up the device Turn on CPR4 by pressing the POWER button and holding it for a few seconds If...

Page 6: ...ages in the CPR4 You navigate to and in between them using the LEFT and RIGHT arrow Menu 1 when you navigate to the left is made for everyday use Here you can manage settings for sensitivity level sou...

Page 7: ...ven is place direction speed This is represented by three sets of symbols Tree symbols indicates whether the movement is detected close to the CPR4 or far away The scale ranges from 1 4 trees If one t...

Page 8: ...g the display background light If used do so with as low intensity as possible to maximize operation time The motion detection of CPR4 is highly sensitive It is therefore very important that the CPR4...

Page 9: ...ve around on the other side and at the same time view the results from CPR4 see more on page 11 Menu 1 Everyday use The first and maybe most important setting to understand is the sensitivity setting...

Page 10: ...ttings menu is accessed by pressing the RIGHT button repeatedly until 6 figures appear The marked function name appears at the bottom of the display To change a parameter simply mark the function and...

Page 11: ...to be charged in separate external unit included If the equipment is not be used for a longer period of time remove the batteries to avoid leakage Mounting support There is support for a mono pod or t...

Page 12: ...me steps you have to walk through the first time you use the Bluetooth interface on your computer and when you connect to a CPR4 for the first time We have one description for all operating systems so...

Page 13: ...ol on the CPR4 display To find out the Com port number afterwards go to the device manager and expand the COM and LPT If several CPR4 s are running at the same time it might be helpful to identify the...

Page 14: ...uilt in Server platform Windows XP Vista 7 or Windows Mobile Approvals Radio EN 300 328 V1 5 1 2004 08 EN 301 489 1 V1 4 1 2002 08 EN 301 489 17 V1 2 1 2002 08 EMC Emissions FCC15B Class B EN55022 Cla...

Page 15: ...satisfaction 1 Year Functional Warranty The warranty is valid during one year after purchase and as long as the unit s enclosure remains undamaged CPR4 is a sensitive instrument If attempts are made...

Page 16: ...www cinside eu...