R599850 - BW MK2015 User Manual
MAINTENANCE
32
• Pull out the lamp unit using the handle.
• Insert the new lamp unit until it is firmly in place.
• Tighten the screws of the lamp unit.
• Attach the lamp cover and fasten the lamp trap screw.
Resetting Lamp Time
After installing a new lamp, reset the lamp time using the OSD menu
Turn On the unit.
b) Browse into the menu Function => Reset Lamp Time.
c) Confirm time reset.
CAUTION DURING LAMP RESET
Reset the lamp time only when you have replaced the lamp.
Never reset it when the lamp is still in use. Otherwise, the approximate standard for gauging replacement
time may be inaccurate, lamp performance may deteriorate and lamp blowout may occur.
15.4 Troubleshooting
WARNING
(orange/red LED)
LAMP (orange LED)
STANDBY/ON
(green/red LED)
When the projector is running for more than 1 minute, the Standby/ON LED will automatically switch
OFF.
Operating LED
ID
WARNING
(orange/red)
LAMP
(orange)
STANDBY/ON
(green or red)
Description
1
-
-
red
Unit is in standby mode.
2
-
-
green
Unit is in operate mode.
3
-
-
blinking green Unit is in operate mode but HIDE is ON. Press again the
HIDE button to obtain a picture.
4
-
-
blinking red
Unit is in cooldown mode (switching off).
5/6
-
orange
-
Lamp time has reached 2900 hours, prepare to replace the
lamp soon. If used in low power mode, replace the lamp
before 4000 hours.