2
3
Assembly Instructions
Cinetto
B-moved.
6. General check of the system
Check that the movement of the doors work properly.
Check the safety system against accidental crush, putting an obstacle between the door while closing and the side
of the furniture.
Make this check to prevent danger or damage determined by a wrong operation of the system.
SOURCE
DEVICE
DEVICE
DEVICE
0 - 48
N/O
SWITCH
During the self-learning cycle the pairing with the remote control is not working.
If the self-learning cycle is not working, because of lack if electricity or for the presence of obstacles disconnect
from the power supply, close manually the doors and start the self-learning cycle again.
4. Pairing of the remote control
To activate the pairing function, press and
release the “REMOTE SET” button on the
control unit. Then a red LED will fl ash
on the control unit. While the LED
is fl ashing, press for at least 3
seconds one of the buttons of
the remote control to pair it.
Multiple control units
can be paired and used
with a single remote
control.
Multiple remote controls
can be paired and used
with the same control
unit.
Pairing must not be activated
during the track memorization
cycle.
To unpair the remote control unit, press and release the
“REMOTE SET” button, after which the red LED will fl ash.
Press the “REMOTE SET” button again and keep it pressed
until the led stops fl ashing. When the button is released, the
red LED will fl ash 5 times to confi rm the unpairing.
The unpairing of a remote control completely eliminates its
association with any control unit. In order to use the remote
control, it will be necessary to pair it again using the standard
procedure.
5. Wiring of the switch on the control unit
The N.O. switch is a normally-opened electric contact, managed by the
control unit.
There is no electric tension on the terminals of the switch. The switch isn’t
a voltage supply.
The switch can manage devices with nominal tension between 0
and 48V and a maximum electric current of 2A.
The wiring between the switch and the devices must be performed
by specialized personnel according to the following scheme.
REMOTE
SET
00:00:03
FREQUENCY: 433,92 MHZ
MAX POWER: 1 mW
DEVICE = 0 - 48V
MAX 2A
SWITCH
N/O
O
I
SOURCE
DEVICE
DEVICE
0 - 48V
MAX 2A
N/O
SWITCH