Christoph F. Bruggaier, Bavariafilmplatz 7, D-82031 Grünwald, Germany
version 1.0, Oct. 2008, page 8 of 9
Maintenance
The SRWpower LE usually does not need service on a regular base when operated in the
specified environment.
If your SRWpower LE was exposed to spill water or rain, it should be dried immediately with
a clean dry cloth. Please make sure that the SRWpower LE is completely dry before
reactivating it.
In case of dust or sand have found their way to the inside of the SRWpower LE, you can use
a vacuum cleaner to remove it carefully through the ventilation holes.
If there are still some particles inside, the grip should be sent in and cleaned by authorized
service personnel.
Please refrain from attempting to service the equipment by yourself without proper training.
There are no user serviceable parts inside.
Technical specifications
input
90-264VAC / 50-60cps, three prong plug
and grounded conductor required
output
14,4V / 100W max., battery buffered
at 20°C ambient temperature
power derating at ambient temperature:
30°C: 90W total output power
35°C: 75W total output power
40°C: 60W total output power
weight
approx. 4,2 kg
environmental conditions during operation:
-20 bis +40°C @ 0-80% rel. humidity
(non-condensing)
environmental conditions, transport and storage:
-25 bis +60°C @ 0-80% rel. humidity
(non-condensing)
IP classification
IP20
Options
Option 01:
alternative XLR output 14,4V / 100W max. combined total,
substitutes the V-mount output
Option 02:
alternative XLR input 14,4V / 100W max., substitutes the V-mount input