2.3 Definition of Switches 

AT_ATX: AT / ATX Power Mode Switch

 

 

Switch 

Definition

 

1-2 (Left) 

AT Power Mode 

2-3 (Right) 

ATX Power Mode (Default) 

 

CLR_CMOS: Clear CMOS Switch 

Switch 

Definition

 

1-2 (Left) 

Normal Status (Default) 

2-3 (Right) 

Clear CMOS 

 
BL_PWR1:    Backlight Power on / off

 

Switch

 

Definition

 

Push 

Backlight Power on / off switching 

 
BL_UP1: Backlight Increase

 

Switch

 

Definition

 

Push 

Backlight Increase 

 

BL_UP2: Backlight Decrease

 

Switch

 

Definition

 

Push 

Backlight Decrease 

 

RESET1: Reset Button 

Switch 

Definition

 

Push 

Reset System 

 

 

 

Summary of Contents for CS-108C/P1101-E50

Page 1: ...Version V1 38 Industrial Panel PC Power Efficient Sunlight Readable Series CS 100 P1100 Series User Manual Industrial Monitor Modular Panel PC ...

Page 2: ...Safety Precautions 8 Package Contents 10 Ordering Information 10 Chapter 1 Product Introductions 12 1 1 Overview 13 1 2 Highlights 13 1 3 Product pictures 14 1 4 Key Features 14 1 5 Hardware Specification 15 1 5 1 CS 108C P1100 15 1 5 2 CS 110HC P1100 19 1 5 3 CS 112HC P1100 23 1 5 4 CS 115C P1100 27 1 5 5 CS 117C P1100 31 1 5 6 CS 119C P1100 35 1 5 7 CS W121C P1100 39 1 5 8 CS W124C P1100 43 1 6 ...

Page 3: ...ng the Top Cover 61 3 2 Installing SO DIMM Memory 62 3 3 Installing Mini PCIe Cards 63 3 4 Installing Antennas 64 3 5 Installing CPU Thermal Pad 66 3 6 Assembling the System 67 3 7 Installing a SATA Hard Drive 68 3 8 Installing a SIM Card 70 3 9 Connecting with CS Display Module 71 3 10 VESA Mount Bracket 73 3 11 Panel Mount 74 Chapter 4 BIOS Setup 78 4 1 BIOS Introduction 79 4 2 Main Setup 80 4 3...

Page 4: ... 4 2 South Bridge 90 4 4 3 South Cluster Configuration 91 4 5 Security Setup 94 4 6 Boot Setup 95 4 7 Save Exit 96 Chapter 5 Product Application 97 5 1 Digital I O DIO application 98 5 1 1 Digital I O Programming Guide 98 5 2 Digital I O DIO Hardware Specification 104 5 2 1 DIO Connector Definition 104 Chapter 6 Optional Modules and Accessories 106 6 1 Location of the Connectors and Switches 107 6...

Page 5: ...or commercial use without the prior written permission of Cincoze Co Ltd All information and specification provided in this manual are for reference only and remain subject to change without prior notice Acknowledgement Cincoze is a registered trademark of Cincoze Co Ltd All registered trademarks and product names mentioned herein are used for identification purposes only and may be trademarks and...

Page 6: ...e any product that proves to be defective under normal operation Defects malfunctions or failures of the warranted product caused by damage resulting from natural disasters such as by lightening flood earthquake etc environmental and atmospheric disturbances other external forces such as power line disturbances plugging the board in under power or incorrect cabling and damage caused by misuse abus...

Page 7: ...aken Limitation of Liability Cincoze liability arising out of the manufacture sale or supplying of the product and its use whether based on warranty contract negligence product liability or otherwise shall not exceed the original selling price of the product The remedies provided herein are the customer s sole and exclusive remedies In no event shall Cincoze be liable for direct indirect special o...

Page 8: ...ay cause damage 7 Make sure the voltage of the power source is correct before connecting the equipment to the power outlet 8 Use a power cord that has been approved for using with the product and that it matches the voltage and current marked on the product s electrical range label The voltage and current rating of the cord must be greater than the voltage and current rating marked on the product ...

Page 9: ...ed Liquid has penetrated into the equipment The equipment has been exposed to moisture The equipment does not work well or you cannot get it work according to the user s manual The equipment has been dropped and damaged The equipment has obvious signs of breakage 14 CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manuf...

Page 10: ...3950 Quad Core Processor and P Cap Touch CS 108C P1101 N42 8 4 TFT LCD 1600nits Sunlight Readable Touch Panel PC with Intel Pentium N4200 Quad Core Processor and P Cap Touch CS 110HC P1101 E50 10 4 TFT LCD 1500nits Sunlight Readable Touch Panel PC with Intel Atom E3950 Quad Core Processor and P Cap Touch CS 110HC P1101 N42 10 4 TFT LCD 1500nits Sunlight Readable Touch Panel PC with Intel Pentium N...

Page 11: ...PC with Intel Atom E3950 Quad Core Processor and P Cap Touch CS 119C P1101 N42 19 TFT LCD 1600nits Sunlight Readable Touch Panel PC with Intel Pentium N4200 Quad Core Processor and P Cap Touch CS W121C P1101 E50 21 5 TFT LCD Full HD 16 9 Modular Touch Panel PC with Intel Atom E3950 Quad Core Processor and P Cap Touch CS W121C P1101 N42 21 5 TFT LCD Full HD 16 9 Modular Touch Panel PC with Intel Pe...

Page 12: ...CS 100 P1100 Series User Manual 12 Chapter 1 Product Introductions ...

Page 13: ... CDS technology Comparing with regular standalone panel PCs it is more flexible and reduces maintenance cost dramatically Featuring with rigorous industrial protections wide range operating temperature 20 C to 70 C IP65 dust waterproof front panel and wide range DC power input 9 to 48VDC CS 100 P1100 Series is appropriate for harsh environments and critical applications 1 2 Highlights Sunlight Rea...

Page 14: ... VGA and DisplayPort outputs Rich I O 2x GbE LAN 4x USB 3 0 4x COM 8x Isolated DIO 2x Full Size Mini PCIe 1x 2 5 SATA Drive Bay 1x mSATA Socket Wide Range Operating Temperature 20 C to 70 C Designed with Aluminum Die casting Front Frame True Flat IP65 Front Panel Protection Supports CDS Technology Ignition Sensing and Power over Ethernet Supports Panel VESA Rack Mounting with optional mounting kit...

Page 15: ...Viewing Angle 160 H 140 V Backlight MTBF 50 000 hrs LED Backlight Touchscreen Touchscreen Type Projected Capacitive Touch Physical Dimension WxDxH 262 x 186 2 x 56 2mm Weight 1 58kg Construction Flat Rugged Aluminum Die casting Bezel Environment Front Panel Protection IP 65 Compliant Operating Temperature Ambient with Air flow 20 C to 70 C extended temperature peripherals Storage Temperature 20 C ...

Page 16: ...oL Teaming Jumbo Frame PXE RJ45 GbE1 Intel I210 GbE2 Intel I210 USB 4x USB 3 2 Gen1 Type A Serial Port 4x RS 232 422 485 with Auto Flow Control Support 5V 12V DB9 DIO 8x Digital I O 4in 4out 10 Pin Terminal Block Power Mode Switch 1x AT ATX Mode Switch Power Switch 1x Power Switch Reset Button 1x Reset Button Clear CMOS Switch 1x Clear CMOS Switch Remote Power On Off 1x Remote Power On Off Connect...

Page 17: ... Reverse Power Input Yes Over Voltage Protection Protection Range 51 58V Protection Type shut down operating voltage re power on at the present level to recover Over Current Protection 15A ESD Protection 8kV air 4kV contact Surge Protection 2kV CMOS Battery Backup SuperCap Integrated for CMOS Battery Maintenance free Operation MTBF Time 294 617 hours Operating System Microsoft Windows Windows 10 L...

Page 18: ...CS 100 P1100 Series User Manual 18 Dimension CS 108C P1101 Unit mm ...

Page 19: ...gle 178 H 178 V Backlight MTBF 50 000 hrs LED Backlight Touchscreen Touch Type Projected Capacitive Physical Dimension WxDxH 295 x 227 3 x 56 2mm Weight 2 24kg Mechanical Construction Flat Rugged Aluminum Die casting Bezel Environment Front Panel Protection IP 65 Compliant Operating Temperature Ambient with Air flow 20 C to 70 C extended temperature peripherals Storage Temperature 20 C to 70 C Rel...

Page 20: ...oL Teaming Jumbo Frame PXE RJ45 GbE1 Intel I210 GbE2 Intel I210 USB 4x USB 3 2 Gen1 Type A Serial Port 4x RS 232 422 485 with Auto Flow Control Support 5V 12V DB9 DIO 8x Digital I O 4in 4out 10 Pin Terminal Block Power Mode Switch 1x AT ATX Mode Switch Power Switch 1x Power Switch Reset Button 1x Reset Button Clear CMOS Switch 1x Clear CMOS Switch Remote Power On Off 1x Remote Power On Off Connect...

Page 21: ... Reverse Power Input Yes Over Voltage Protection Protection Range 51 58V Protection Type shut down operating voltage re power on at the present level to recover Over Current Protection 15A ESD Protection 8kV air 4kV contact Surge Protection 2kV CMOS Battery Backup SuperCap Integrated for CMOS Battery Maintenance free Operation MTBF Time 294 617 hours Operating System Microsoft Windows Windows 10 L...

Page 22: ...CS 100 P1100 Series User Manual 22 Dimension CS 110HC P1101 Unit mm ...

Page 23: ...ing Angle 160 160 Backlight MTBF 30 000 hrs LED Backlight Touchscreen Touch Type Projected Capacitive Physical Dimension WxDxH 345 x 265 3 x 57 mm Weight 3 16 kg Construction Flat Rugged Aluminum Die casting Bezel Environment Front Panel Protection IP 65 Compliant Operating Temperature Ambient with Air flow 20 C to 70 C extended temperature peripherals Storage Temperature 20 C to 70 C Relative Hum...

Page 24: ...oL Teaming Jumbo Frame PXE RJ45 GbE1 Intel I210 GbE2 Intel I210 USB 4x USB 3 2 Gen1 Type A Serial Port 4x RS 232 422 485 with Auto Flow Control Support 5V 12V DB9 DIO 8x Digital I O 4in 4out 10 Pin Terminal Block Power Mode Switch 1x AT ATX Mode Switch Power Switch 1x Power Switch Reset Button 1x Reset Button Clear CMOS Switch 1x Clear CMOS Switch Remote Power On Off 1x Remote Power On Off Connect...

Page 25: ... Reverse Power Input Yes Over Voltage Protection Protection Range 51 58V Protection Type shut down operating voltage re power on at the present level to recover Over Current Protection 15A ESD Protection 8kV air 4kV contact Surge Protection 2kV CMOS Battery Backup SuperCap Integrated for CMOS Battery Maintenance free Operation MTBF Time 294 617 hours Operating System Microsoft Windows Windows 10 L...

Page 26: ...CS 100 P1100 Series User Manual 26 Dimension CS 112HC P1101 Unit mm ...

Page 27: ...e 160 150 Backlight MTBF 50 000 hrs LED Backlight Touchscreen Touchscreen Type Projected Capacitive Touch Physical Dimension WxDxH 408 x 312 4 x 59 2 mm Weight 4 36kg Construction Flat Rugged Aluminum Die casting Bezel Environment Front Panel Protection IP 65 Compliant Operating Temperature Ambient with Air flow 20 C to 70 C extended temperature peripherals Storage Temperature 20 C to 70 C Relativ...

Page 28: ...oL Teaming Jumbo Frame PXE RJ45 GbE1 Intel I210 GbE2 Intel I210 USB 4x USB 3 2 Gen1 Type A Serial Port 4x RS 232 422 485 with Auto Flow Control Support 5V 12V DB9 DIO 8x Digital I O 4in 4out 10 Pin Terminal Block Power Mode Switch 1x AT ATX Mode Switch Power Switch 1x Power Switch Reset Button 1x Reset Button Clear CMOS Switch 1x Clear CMOS Switch Remote Power On Off 1x Remote Power On Off Connect...

Page 29: ... Reverse Power Input Yes Over Voltage Protection Protection Range 51 58V Protection Type shut down operating voltage re power on at the present level to recover Over Current Protection 15A ESD Protection 8kV air 4kV contact Surge Protection 2kV CMOS Battery Backup SuperCap Integrated for CMOS Battery Maintenance free Operation MTBF Time 294 617 hours Operating System Microsoft Windows Windows 10 L...

Page 30: ...CS 100 P1100 Series User Manual 30 Dimension CS 115C P1101 Unit mm ...

Page 31: ...gle 160 140 Backlight MTBF 50 000 hrs LED Backlight Touchscreen Touchscreen Type Projected Capacitive Touch Physical Dimension WxDxH 450 x 350 x 63 2mm Weight 5 64 kg Construction Flat Rugged Aluminum Die casting Bezel Environment Front Panel Protection IP 65 Compliant Operating Temperature Ambient with Air flow 20 C to 70 C extended temperature peripherals Storage Temperature 20 C to 70 C Relativ...

Page 32: ...oL Teaming Jumbo Frame PXE RJ45 GbE1 Intel I210 GbE2 Intel I210 USB 4x USB 3 2 Gen1 Type A Serial Port 4x RS 232 422 485 with Auto Flow Control Support 5V 12V DB9 DIO 8x Digital I O 4in 4out 10 Pin Terminal Block Power Mode Switch 1x AT ATX Mode Switch Power Switch 1x Power Switch Reset Button 1x Reset Button Clear CMOS Switch 1x Clear CMOS Switch Remote Power On Off 1x Remote Power On Off Connect...

Page 33: ... Reverse Power Input Yes Over Voltage Protection Protection Range 51 58V Protection Type shut down operating voltage re power on at the present level to recover Over Current Protection 15A ESD Protection 8kV air 4kV contact Surge Protection 2kV CMOS Battery Backup SuperCap Integrated for CMOS Battery Maintenance free Operation MTBF Time 294 617 hours Operating System Microsoft Windows Windows 10 L...

Page 34: ...CS 100 P1100 Series User Manual 34 Dimension CS 117C P1101 Unit mm ...

Page 35: ...170 160 Backlight MTBF 50 000 hrs LED Backlight Touchscreen Touch Type Projected Capacitive Physical Dimension WxDxH 510 x 389 3 x 63 2 mm Weight 6 96 kg Construction Flat Rugged Aluminum Die casting Bezel Environment Front Panel Protection IP 65 Compliant Operating Temperature Ambient with Air flow 20 C to 70 C extended temperature peripherals Storage Temperature 20 C to 70 C Relative Humidity 80...

Page 36: ...oL Teaming Jumbo Frame PXE RJ45 GbE1 Intel I210 GbE2 Intel I210 USB 4x USB 3 2 Gen1 Type A Serial Port 4x RS 232 422 485 with Auto Flow Control Support 5V 12V DB9 DIO 8x Digital I O 4in 4out 10 Pin Terminal Block Power Mode Switch 1x AT ATX Mode Switch Power Switch 1x Power Switch Reset Button 1x Reset Button Clear CMOS Switch 1x Clear CMOS Switch Remote Power On Off 1x Remote Power On Off Connect...

Page 37: ... Reverse Power Input Yes Over Voltage Protection Protection Range 51 58V Protection Type shut down operating voltage re power on at the present level to recover Over Current Protection 15A ESD Protection 8kV air 4kV contact Surge Protection 2kV CMOS Battery Backup SuperCap Integrated for CMOS Battery Maintenance free Operation MTBF Time 294 617 hours Operating System Microsoft Windows Windows 10 L...

Page 38: ...CS 100 P1100 Series User Manual 38 Dimension CS 119C P1101 Unit mm ...

Page 39: ...ng Angle 178 178 Backlight MTBF 50 000 hrs LED Backlight Touchscreen Touch Type Projected Capacitive Physical Dimension WxDxH 550 x 330 5 x 63 2mm Weight 5 56 kg Construction Flat Rugged Aluminum Die casting Bezel Environment Front Panel Protection IP 65 Compliant Operating Temperature Ambient with Air flow 0 C to 70 C extended temperature peripherals Storage Temperature 20 C to 70 C Relative Humi...

Page 40: ...oL Teaming Jumbo Frame PXE RJ45 GbE1 Intel I210 GbE2 Intel I210 USB 4x USB 3 2 Gen1 Type A Serial Port 4x RS 232 422 485 with Auto Flow Control Support 5V 12V DB9 DIO 8x Digital I O 4in 4out 10 Pin Terminal Block Power Mode Switch 1x AT ATX Mode Switch Power Switch 1x Power Switch Reset Button 1x Reset Button Clear CMOS Switch 1x Clear CMOS Switch Remote Power On Off 1x Remote Power On Off Connect...

Page 41: ... Reverse Power Input Yes Over Voltage Protection Protection Range 51 58V Protection Type shut down operating voltage re power on at the present level to recover Over Current Protection 15A ESD Protection 8kV air 4kV contact Surge Protection 2kV CMOS Battery Backup SuperCap Integrated for CMOS Battery Maintenance free Operation MTBF Time 294 617 hours Operating System Microsoft Windows Windows 10 L...

Page 42: ...CS 100 P1100 Series User Manual 42 Dimension CS W121C P1101 Unit mm ...

Page 43: ...gle 178 178 Backlight MTBF 50 000 hrs LED Backlight Touchscreen Touch Type Projected Capacitive Physical Dimension WxDxH 605 x 373 x 63 2 mm Weight 6 64 kg Construction Flat Rugged Aluminum Die casting Bezel Environment Front Panel Protection IP 65 Compliant Operating Temperature Ambient with Air flow 20 C to 70 C extended temperature peripherals Storage Temperature 20 C to 70 C Relative Humidity ...

Page 44: ...oL Teaming Jumbo Frame PXE RJ45 GbE1 Intel I210 GbE2 Intel I210 USB 4x USB 3 2 Gen1 Type A Serial Port 4x RS 232 422 485 with Auto Flow Control Support 5V 12V DB9 DIO 8x Digital I O 4in 4out 10 Pin Terminal Block Power Mode Switch 1x AT ATX Mode Switch Power Switch 1x Power Switch Reset Button 1x Reset Button Clear CMOS Switch 1x Clear CMOS Switch Remote Power On Off 1x Remote Power On Off Connect...

Page 45: ... Reverse Power Input Yes Over Voltage Protection Protection Range 51 58V Protection Type shut down operating voltage re power on at the present level to recover Over Current Protection 15A ESD Protection 8kV air 4kV contact Surge Protection 2kV CMOS Battery Backup SuperCap Integrated for CMOS Battery Maintenance free Operation MTBF Time 294 617 hours Operating System Microsoft Windows Windows 10 L...

Page 46: ...CS 100 P1100 Series User Manual 46 Dimension CS W124C P1101 Unit mm ...

Page 47: ...itch Used to set up IGN function 12 24V Switch Used to select IGN Voltage Removable HDD Used to inserts a 2 5 HDD SSD 1 6 2 Rear DC IN Terminal Block Used to plug a DC power input with terminal block USB 3 2 GEN1 port Used to connect USB 3 2 GEN1 2 0 1 1 device LAN port Used to connect the system to a local area network VGA Used to connect an analog VGA monitor Display Port Used to connect the sys...

Page 48: ... LCD On Off Press to turn on or turn off the display USB 3 2 GEN1 port Used to connect USB 3 2 GEN1 2 0 1 1 device COM port COM 3 4 support RS232 422 485 serial device 1 6 4 Side Left COM port COM 2 supports RS232 422 485 serial device Digital I O Terminal Block The Digital I O terminal block supports 4 digital input and 4 digital output USB 3 2 GEN1 port Used to connect USB 3 2 GEN1 2 0 1 1 devic...

Page 49: ...CS 100 P1100 Series User Manual 49 1 6 5 Top VESA Mounting Hole These are mounting holes for VESA mount 75x75mm and 100x100mm ...

Page 50: ...CS 100 P1100 Series User Manual 50 Chapter 2 Switches Connectors ...

Page 51: ...CS 100 P1100 Series User Manual 51 2 1 Location of Switches and Connectors 2 1 1 Top View ...

Page 52: ...CS 100 P1100 Series User Manual 52 2 1 2 Bottom View ...

Page 53: ...nector DC_IN1 3 pin DC 9 48V Power Input with Power Ignition Connector LAN1 LAN Connector LAN2 LAN Connector VGA1 VGA Connector DP1 DisplayPort Connector PWR_SW2 Power Switch Connector DIO1 4DI 4DO Connector MIC_IN1 Mic in Jack LINE_OUT1 Line Out Jack SW1 Super CAP SW COM3 4 with Power Select SW2 COM1 2 with Power Select MINIPCIE1 Mini PCI Express SIM USB3 Socket MINIPCIE2 Mini PCI Express mSATA S...

Page 54: ..._CMOS Clear CMOS Switch Switch Definition 1 2 Left Normal Status Default 2 3 Right Clear CMOS BL_PWR1 Backlight Power on off Switch Definition Push Backlight Power on off switching BL_UP1 Backlight Increase Switch Definition Push Backlight Increase BL_UP2 Backlight Decrease Switch Definition Push Backlight Decrease RESET1 Reset Button Switch Definition Push Reset System ...

Page 55: ...FF OFF Location Function DIP5 DIP6 SW1 COM4 0V RI ON Default ON Default 5V ON OFF 12V OFF OFF SW2 COM1 2 with Power Select Location Function DIP1 DIP2 SW2 COM1 0V RI ON Default ON Default 5V ON OFF 12V OFF OFF Location Function DIP3 DIP4 SW2 COM2 0V RI ON Default ON Default 5V ON OFF 12V OFF OFF LED1 Power HDD Access LED Status LED LED Color Status POWER Green POWER ON HDD Blinking Yellow HDD Read...

Page 56: ...A 21 GND 39 RESERVED 4 GND 22 PERST 40 GND 5 NA 23 PERN0 USB3RN0 SATARP0 41 3 3V 6 1 5V 24 3 3V 42 NA 7 CLKREQ 25 PERP0 USB3RP0 SATARN0 43 GND 8 SIM_VCC 26 GND 44 NA 9 GND 27 GND 45 NA 10 SIM_DATA 28 1 5V 46 NA 11 REFCLK 29 GND 47 NA 12 SIM_CLK 30 SMB_CLK 48 1 5V 13 REFCLK 31 PETN0 USB3TN0 SATATN0 49 NA 14 SIM_Reset 32 SMB_DATA 50 GND 15 GND 33 PETP0 USB3TP0 SATATP0 51 NA 16 SIM_VPP 34 GND 52 3 3V...

Page 57: ...USB_D 3 NA 21 GND 39 3 3V 4 GND 22 PERST 40 GND 5 NA 23 PERN0 SATARP0 41 3 3V 6 1 5V 24 3 3VAUX 42 NA 7 CLKREQ 25 PERP0 SATARN0 43 GND 8 NA 26 GND 44 NA 9 GND 27 GND 45 NA 10 NA 28 1 5V 46 NA 11 REFCLK 29 GND 47 NA 12 NA 30 SMB_CLK 48 1 5V 13 REFCLK 31 PETN0 ATATN0 49 NA 14 NA 32 SMB_DATA 50 GND 15 GND 33 PETP0 SATATP0 51 NA 16 NA 34 GND 52 3 3V 17 NA 35 GND 18 GND 36 USB_D ...

Page 58: ...D LAN1 LAN2 LAN LED Status Definition Act LED Status Definition Blinking Yellow Data Activity Off No Activity Link LED Status Definition Steady Green 1Gbps Network Link Steady Orange 100Mbps Network Link Off 10Mbps Network Link Do not apply power to this connector This port is used to connect a SWITCH WARNING Please disconnect the power source before mounting the DC power cables or connecting the ...

Page 59: ...tor Type 9 pin D Sub Pin RS232 Definition RS422 485 Full Duplex Definition RS485 Half Duplex Definition 1 DCD TX DATA 2 RXD TX DATA 3 TXD RX 4 DTR RX 5 GND 6 DSR 7 RTS 8 CTS 9 RI POWER1 POWER2 Power Connector Connector Type 1x4 4 pin Wafer 2 0mm pitch Pin Definition 1 5V 2 GND 3 GND 4 12V Pin 1 Gap ...

Page 60: ...CS 100 P1100 Series User Manual 60 Chapter 3 System Setup ...

Page 61: ...CS 100 P1100 Series User Manual 61 3 1 Removing the Top Cover 1 Loosen the 8 screws of front and rear panel then place them aside 2 Remove the cover from the chassis 3 Place the top cover gently ...

Page 62: ...ocate the SO DIMM sockets 2 Tilt the SO DIMM module at a 45 degree angle and insert it to SO DIMM socket until the gold pated connector of module contacted firmly with the socket 3 Press the modules down until it s fixed firmly by the two locking latches on each side 45 ...

Page 63: ...ble for full or half size card 1 Locate the Mini PCIe slot 2 Insert the Mini PCIe card at a 45 degree angle and insert it to the slot until the gold pated connector of module contacted firmly with the slot 3 Press down the module and fasten two screws to secure the module 45 ...

Page 64: ...anual 64 4 If you have a Half size Mini PCIe card make sure use extender to make it Full size as shown below 3 4 Installing Antennas 1 Remove the antenna hole covers at front panel 2 Have antenna jack penetrate through the hole ...

Page 65: ...CS 100 P1100 Series User Manual 65 3 Put on washer and fasten the nut with antenna jack 4 Assemble the antenna and antenna jack together 5 Attach the RF connector at another end of cable onto the module ...

Page 66: ...r Manual 66 3 5 Installing CPU Thermal Pad 1 Place the thermal pad on the CPU heatsink Before assembling the system s chassis cover please make sure the protective film on the Thermal Pad has been removed CAUTION thermal pad ...

Page 67: ...CS 100 P1100 Series User Manual 67 3 6 Assembling the System 1 Put on the cover 2 Fasten the 8 screws to fix the cover ...

Page 68: ...00 Series User Manual 68 3 7 Installing a SATA Hard Drive 1 Loosen 2 screws on front panel to remove cover plate 2 Turn over the unit to have the bottom side face up and loosen 1 screw 3 Pull out the HDD bracket ...

Page 69: ...place the HDD bracket on it Ensure the direction of bracket is correct and use 4 provided screws to assemble HDD and HDD bracket together 5 Align the HDD bracket with the entrance of HDD bay And insert the HDD bracket until the connector of HDD contact the SATA connector firmly ...

Page 70: ...CS 100 P1100 Series User Manual 70 3 8 Installing a SIM Card 1 Loosen 2 screws on front panel to remove cover plate 2 SIM card slot is at the front panel of the system 3 Insert the SIM card ...

Page 71: ... with CS Display Module 1 Locate the module connector slot 2 Turn over the unit to have the bottom side face up loosen the 2 screws of the module connector bracket The photos show the male connector on display module and female connector on PC module ...

Page 72: ...CS 100 P1100 Series User Manual 72 3 Connect the module 4 Fasten the 6 screws to fix the PC module on the display module ...

Page 73: ...cates VESA mounting hole pattern on P1100 series which is compliant with VESA mounting standard 1 The following picture uses a panel PC P1100 series CS display module as a demonstration To attach the panel PC to a VESA stand please fasten eight screws as indicated to fix it on the stand ...

Page 74: ...CS 100 P1100 Series User Manual 74 3 11 Panel Mount 1 Accessories provided by Cincoze are as follows ...

Page 75: ...CS 100 P1100 Series User Manual 75 2 All mounting kits displayed are to be inserted into holes 3 Installation preparation and steps ...

Page 76: ...CS 100 P1100 Series User Manual 76 ...

Page 77: ...CS 100 P1100 Series User Manual 77 4 Apply all mount kits to the rest of holes And you have completed the panel mount installation as shown below ...

Page 78: ...CS 100 P1100 Series User Manual 78 Chapter 4 BIOS Setup ...

Page 79: ...elect item Esc Quit the BIOS Setup Enter Select item Page Up Increases the numeric value or makes changes Page Down Decreases the numeric value or makes changes Tab Select setup fields F1 General help F2 Previous value F3 Load Optimized defaults F10 Save configuration and Exit Main Menu The main menu lists the setup functions you can make changes to You can use the arrow keys to select the item Th...

Page 80: ...he Main Menu as shown below will appears on the screen Use arrow keys to move among the items and press Enter to accept or enter a sub menu 4 2 1 System Date Set the date Please use Tab to switch between date elements 4 2 2 System Time Set the time Please use Tab to switch between time elements ...

Page 81: ...lows you to set up some system features according to your preference 4 3 1 Trusted Computing Settings Security Device Support Enabled Enables or disables Security Device Support function SHA 1 PCR Bank Enabled Enables or disables SHA 1 PCR Bank function SHA256 PCR Bank Enabled Enables or disables SHA256 PCR Bank function ...

Page 82: ...cal Presence Spec Version will operate Configuration options 1 2 1 3 4 3 2 ACPI Settings Enable ACPI Auto Configuration Disabled Enables or disables BIOS Advanced Configuration Power Interface ACPI auto configuration Enable Hibernation Enabled Enables or disables system ability to hibernate state OS S4 state This option may not be effective with some OS ACPI Sleep State S3 Suspend to RAM Allows us...

Page 83: ...3 Enables or disables Lock Legacy Resources 4 3 3 F81866 Super IO Configuration Set Parameters of Serial Ports User can Enable Disable the serial port and Select an optimal setting for the Super IO Device Serial Port 1 4 Configuration ...

Page 84: ...select Serial Port Mode Configuration options RS232 RS422 RS485 Full Duplex RS485 Half Duplex Watch Dog Disabled Enables or disables watch dog function Watch Dog Mode Sec Allows to set watchdog timer unit Sec or Min Watch Dog Timer 0 Allows you to set watchdog timer s value in the range of 0 to 255 4 3 4 Hardware Monitor This screen displays the current status of all monitored hardware devices com...

Page 85: ...off state Disabled Disables wake system from S5 Fixed Time Sets a fixed time HH MM SS to wake system from S5 Dynamic Time Sets an increase minute s from current time to wake system from S5 4 3 6 Serial Port Console Redirection Console Redirection Disabled Allow users to enable or disable COM1 COM2 COM3 COM4 console redirection function ...

Page 86: ...es to enable in each processor package Intel Virtualization Technology Enabled Enables or disables Intel Virtualization Technology Virtualization enhanced by Intel Virtualization Technology will allow a platform to run multiple operating systems and applications in independent partitions With virtualization one computer system can function as multiple virtual systems 4 3 8 Network Stack Configurat...

Page 87: ...rating systems that only support legacy option ROM UEFI only Allows booting from operating systems that only support UEFI option ROM Network PXE Do not launch Controls the execution of UEFI and Legacy PXE Network Preboot eXecution Environment option ROM Do not launch Disables option ROM execution UEFI Enables UEFI option ROM only Legacy Enables legacy option ROM only Storage UEFI Controls the exec...

Page 88: ...B Configuration Legacy USB Support Enabled This item allows you to enable or disable legacy USB support When set to Auto legacy USB support will be disabled automatically if no USB devices are connected XHCI Hand off Enabled Enables or disables XHCI USB3 0 hand off function Use this feature as a workaround for operating systems without XHCI hand off support USB Mass Storage Driver Support Enabled ...

Page 89: ...pset Setup This section allows you to configure chipset related settings according to user s preference 4 4 1 North Bridge This section provides information on the installed memory size and memory onboard graphics related configuration options ...

Page 90: ...itch Mini PCIE Allows you to change Mini PCIE1 as Mini PCIE or USB3 Mini PCIE2 mSATA Switch Mini PCIE Allows you to change Mini PCIE2 as Mini PCIE or mSATA Amplifier Function Enabled Enables or disables Amplifier Function PSE Enable Selection Enabled Enables or disables PSE Power Sourcing Equipment LAN1 Enabled Enables or disables LAN1 Controller LAN2 Enabled Enables or disables LAN2 Controller ...

Page 91: ...Port 5 MiniPcie2 PCI Express Root Port 5 MiniPcie2 Enabled Enables or disables PCI Express Root Port PCIe Speed Auto Allows you to select PCI Express port speed Configuration options Auto Gen1 Gen2 PCI Express Root Port 6 MiniPcie PCI Express Root Port 6 MiniPcie Enabled Enables or disables PCI Express Root Port ...

Page 92: ...llows you to select PCI Express port speed Configuration options Auto Gen1 Gen2 SATA Devices SATA Port 0 Port 0 Enabled Enables or disables SATA Port 0 SATA1 SATA Port 1 Port 1 Enabled Enables or disables SATA Port 1 MINIPCIE2 Miscellaneous Configuration ...

Page 93: ...failure G3 state Always on Enters to power on state Always off Enters to power off state Last state Enters to the last power state before a power failure sables Wake On Lan Enabled Enables or disables Wake On LAN WOL function BIOS Lock Disabled Enables or disables BIOS the SC BIOS Lock enable feature It is required to be enabled to ensure SMM protection of flash ...

Page 94: ...his section allows users to configure BIOS security settings 4 5 1 Administrator Password Administrator Password controls access to the BIOS Setup utility 4 5 2 User Password User Password controls access to the system at boot and to the BIOS Setup utility ...

Page 95: ...n or Off state when system boots up Quiet Boot Allows you to enable or disable Quiet Boot function Fast Boot Allows you to enable or disable Fast Boot function If enabled system boots with initialization of a minimal set of devices required to launch active boot option Hard Drive BBS Priority Allows you to set the order of the legacy devices in this group ...

Page 96: ...set This item allows you to reset system setup without saving any changes Restore Defaults This item allows you to restore load default values for all the setup options Save as User Defaults This item allows you to save the changes done so far as user defaults Restore User Defaults This item allows you to restore the user defaults to all the setup options ...

Page 97: ...CS 100 P1100 Series User Manual 97 Chapter 5 Product Application ...

Page 98: ...isters the following configuration procedures must be followed in sequence 1 Enter the Extended Function Mode 2 Configure the configuration registers 3 Exit the Extended Function Mode The configuration register is used to control the behavior of the corresponding devices To configure the register use the index port to select the index and then write data port to alter the parameters The default in...

Page 99: ...CS 100 P1100 Series User Manual 99 5 1 1 3 Relative Registers To program the F81866A configuration registers see the following configuration procedures ...

Page 100: ...ended mode Select Logic Device WriteByte AddrPort 0x07 WriteByte dataPort 0x06 Select logic device 06h Input Mode Selection Set GP74 to GP77 input Mode WriteByte AddrPort 0x80 Select configuration register 80h WriteByte DataPort 0x0X Set bit 4 7 0 to select GP 74 77 as Input mode Input Value WriteByte AddrPort 0x82 Select configuration register 82h ReadByte DataPort Value Read bit 4 7 0xFF GP74 77...

Page 101: ...ice WriteByte AddrPort 0x07 WriteByte DataPort 0x06 Select logic device 06h Output Mode Selection Set GP80 to GP83 output Mode WriteByte AddrPort 0x88 Select configuration register 88h WriteByte DataPort 0xXF Set bit 0 3 1 to select GP 80 83 as Output mode Output Value WriteByte AddrPort 0x89 Select configuration register 89h WriteByte DataPort Value Set bit 0 3 0 1 to output GP 80 83 as Low or Hi...

Page 102: ...r Extended mode Select Logic Device WriteByte AddrPort 0x07 WriteByte dataPort 0x06 Select logic device 06h WriteByte AddrPort 0x60 Select configuration register 60h High Byte address WriteByte DataPort 0x0A WriteByte AddrPort 0x61 Select configuration register 61h Low Byte address WriteByte DataPort 0x00 Leave the Extended Function Mode WriteByte AddrPort 0xAA Note Cincoze DIO Port base address i...

Page 103: ...0 bit 0 0 0 1 value h X 1 DO1 7 6 5 4 3 2 1 0 bit 0 0 1 0 value h 2 X DI2 7 6 5 4 3 2 1 0 bit 0 0 1 0 value h X 2 DO2 7 6 5 4 3 2 1 0 bit 0 1 0 0 value h 4 X DI3 7 6 5 4 3 2 1 0 bit 0 1 0 0 value h X 4 DO3 7 6 5 4 3 2 1 0 bit 1 0 0 0 value h 8 X DI4 7 6 5 4 3 2 1 0 bit 1 0 0 0 value h X 8 DO4 5 1 1 7 DIO I O Port Address ...

Page 104: ...3V Input Driving Sink Current Minimal 1 mA Normal 5 mA 4x Digital Output Open Drain DO Signal have to pull up resistor to XCOM for external device the resistance will affect the pull up current Signal High Level Pull up resistor to XCOM Signal Low Level XCOM Sink Current 1A Max 5 2 1 DIO Connector Definition DIO1 Digital Input Output Connector Connector Type Terminal Block 1X10 10 pin 3 5mm pitch ...

Page 105: ...CS 100 P1100 Series User Manual 105 ...

Page 106: ...CS 100 P1100 Series User Manual 106 Chapter 6 Optional Modules and Accessories Pin Definitions and Settings ...

Page 107: ...er Ignition Sensing Control Function 12V 24V Selectable CFM PoE02 CFM Module with PoE Control Function Individual Port 25 5W 6 2 Installing a CFM IGN Module 1 Locate the IGN connector on system motherboard as indicated 2 Insert CFM IGN module vertically to the female connector on the system s mainboard and fasten 2 screws to fix it ...

Page 108: ...Switch Set shutdown delay timer when ACC is turned off Pin 1 Pin 2 Pin 3 Pin 4 Definition OFF ON ON ON ON 0 second ON ON OFF 1 minute ON OFF ON 5 minutes ON OFF OFF 10 minutes OFF ON ON 30 minutes OFF ON OFF 1 hour OFF OFF ON 2 hours OFF OFF OFF Reserved 0 second 24V_12V_1 12V 24V Car Battery Switch Pin Definition 1 2 24V Car Battery Input 2 3 12V Car Battery Input ...

Page 109: ...s indicated 2 Insert the female connector of CFM PoE module to the male connector on system motherboard 3 Turn over the heatsink and paste the thermal pad onto the marked by red squares Before putting on the thermal block in the next step please make sure the protective film on the Thermal Pad has been removed CAUTION ...

Page 110: ...to fix it 5 Paste the thermal pads onto the heatsink and coil carefully 6 When the system is power on please note that the POE LED will light on if the POE module is properly installed Before assembling the system s chassis cover please make sure the protective films on the Thermal Pads have been removed CAUTION ...

Page 111: ...registered trademark of Cincoze Co Ltd All other logos appearing in this catalog are the intellectual property of the respective company product or organization associated with the logo All product specifications and information are subject to change without notice ...