background image

OMM-23-1009-page 3

3. Air Pressure and Suction:

In addition to the normal dangers of rotating machinery, the blower can present additional hazards from the suction or
pressure created at the blower inlet or discharge. Suction at the blower inlet can draw materials into the blower where
they become high velocity projectiles at the discharge and cause severe personal injury or death. It can also be
extremely dangerous to persons in close proximity to the inlet or discharge as the forces involved can overcome the
strength of most individuals.

NEVER OPERATE A BLOWER WITH A NON-DUCTED INLET AND/OR DISCHARGE. IF THE BLOWER INLET

AND/OR DISCHARGE IS NON-DUCTED, IT IS THE USERS RESPONSIBILITY TO INSTALL AN

INLET AND/OR DISCHARGE GUARD.

NO GUARANTEE OF ANY LEVEL OF SPARK RESISTANCE IS IMPLIED BY SPARK RESISTANT

CONSTRUCTION. IT HAS BEEN DEMONSTRATED THAT ALUMINUM IMPELLERS RUBBING ON RUSTY

STEEL CAN CAUSE HIGH INTENSITY SPARKS. AIR STREAM MATERIAL AND DEBRIS OR OTHER SYSTEM

FACTORS CAN ALSO CAUSE SPARKS.

4. Temperature:

Many blowers, blower components and all motors operate at temperatures that could burn someone if they come in
contact with them. If this potential hazard could exist in your installation, steps must be taken by the user to protect any-
one from coming in contact with this equipment.

5. Spark Resistance;

(Per AMCA Standard 99-0401-86 and ISO 13499)

6. Safety Accessories;

Guards:

All moving parts must be guarded to protect personnel. Safety requirements can vary, so the number and types of
guards required to meet company, local, state and OSHA regulations must be determined and specified by the actual
user or operator of the equipment.

NEVER start any blower without having all required safety guards properly installed. All blowers should be
checked on a regular schedule, for missing or damaged guards. If any required guards are found to be missing
or defective, the power to the blower should be immediately turned off and locked out in accordance with
OSHA regulations. Power to the blower should NOT be tuned back on until the required guards have been
repaired or replaced.

This blower can become dangerous due to a potential “windmill” effect, even though all electrical power has been
turned off or disconnected. The blower wheel should be

carefully

secured to prevent any rotational turning

BEFORE

working on any parts of the blower/motor assembly that could move.

7. Access or Inspection Doors:

II. INSTALLATION

A. Vibration:

Before any mounting method is selected, the user should be aware of the effects vibration will have on the blower,
motor and other parts. Improper blower installation can cause excessive vibration causing premature wheel and/or
motor bearing failure, that is not covered under warranty. Vibration eliminator pads, springs or bases should be properly
installed to prevent any blower vibration from transmitting to the foundation, support structure or ducting.

B. Mounting Methods:

1. Floor Mounted Units;

Centrifugal blowers should be mounted on a flat, level, concrete foundation weighing 2-3 times the weight of the com-
plete blower/motor assembly. It is recommended that the foundation be at least 6 inches larger than the base of the
blower. The foundation should include anchor bolts such as shown in

Fig. 1

on page 4. Place the blower over the

anchor bolts and shim under each bolt until the blower is level. After shimming, flat washers, lock washers and lock nuts
should be tightened at each anchor bolt. Any gaps between the blower base and the foundation should be grouted. If
the blower will be sitting on some type of vibration pads or mounts,

follow the recommended mounting procedures

supplied with the vibration elimination equipment.

WARNING

DANGER

I

SHUT THE BLOWER DOWN IMMEDIATELY IF THERE IS ANY SUDDEN INCREASE IN VIBRATION.

WARNING

NEVER OPEN ANY ACCESS OR INSPECTION DOORS WHILE THE BLOWER IS OPERATING. SERIOUS INJURY OR

DEATH COULD RESULT FROM THE AFFECTS OF AIR PRESSURE, AIR SUCTION OR MATERIAL THAT IS BEING

CONVEYED. DISCONNECT OR LOCK OUT POWER TO THE BLOWER AND LET THE BLOWER WHEEL COME TO A

COMPLETE STOP

BEFORE

OPENING ANY TYPE OF ACCESS OR INSPECTION DOOR.

DANGER

Summary of Contents for LM

Page 1: ... need to order any replacement parts special instructions may be required NOTICE LONG TERM STORAGE NOTICE If this blower will NOT be installed and put into operation within 30 days refer to the Long Term Storage Instructions on pages 12 and 13 Failure to follow all applicable long term storage instructions will void your warranty This blower should be stored indoors in a clean dry location BLOWER ...

Page 2: ...r when removing it from the packaging container All the packaging material should be kept in the event the blower needs to be returned Handling Handling of the blower should be performed by trained personnel and be consistent with all safe handling practices Verify that all lifting equipment is in good operating condition and has the proper lifting capacity The blower should be lifted using well p...

Page 3: ...dance with OSHA regulations Power to the blower should NOT be tuned back on until the required guards have been repaired or replaced This blower can become dangerous due to a potential windmill effect even though all electrical power has been turned off or disconnected The blower wheel should be carefully secured to prevent any rotational turning BEFORE working on any parts of the blower motor ass...

Page 4: ...eters from the blower Any duct elbows located closer than 2 wheel diameters to the blower inlet or discharge WILL reduce the air performance and blower efficiency Any duct elbows near the blower discharge should be in the same rotational direction as the blower rotation Non Ducted Blower Inlet Any blower with no ducting on the inlet must have an inlet guard The blower should be located so the blow...

Page 5: ...ay fuses or breakers should be used since the initial start up time for the blower motor although rare can be up to 10 seconds B Motors 1 DO NOT connect or operate a motor without reading the motor manufacturers instructions supplied with the blower The basic principle of motor maintenance is KEEP THE MOTOR CLEAN AND DRY This requires periodic inspections of the motor The frequency of the inspecti...

Page 6: ... selected based on the atmosphere and or environmental conditions the motor will be operating in Consult the NEC National Electric Code and the NFPA National Fire Protection Association for the proper EXP motor Class Group and T Code required for your specific application and location NOTICE a All EXP motors have some type of thermal overload as required by UL Underwriters Laboratories Refer to al...

Page 7: ... to a gradual rate of temperature increase not to exceed 15 F minute 8 C minute The same temperature limits are also important when the blower is experiencing a drop in temperature until the temperature drops down to 150 F 65 C Only when the entire blower has reached an equilibrium tempera ture of 150 F 65 C or less should the power be turned off 12 Make sure the power source connections to the bl...

Page 8: ...end as per Fig 3 below After you have taken your vibration readings write them down in the spaces below and keep for future comparison OMM 23 1009 page 8 If the blower is going to be conveying material it is the users responsibility to periodically turn the blower off and lock out the power The blower wheel should then be checked for material build up and or erosion If material has built up on any...

Page 9: ... CINCINNATI FAN OR OUR SALES OFFICE FOR YOUR TERRITORY TO DETERMINE IF THE UNIT WILL OPERATE SAFELY AT THE NEW CONDITIONS WARNING V ROUTINE INSPECTION MAINTENANCE Periodic inspection of all the blower parts is the key to good maintenance and trouble free operation The frequency of inspections must be determined by the user and is dependent upon the severity of the application BUT it should NEVER e...

Page 10: ...through the motor and damage the motor bearings 2 Grinding off material for cast aluminum wheels If you are grinding on the wheel to remove material be very careful not to grind too much in one area That could affect the structural integrity of the wheel 3 Forward curved wheels Model LM only also known as squirrel cage or multivane wheels These wheels have balancing clips attached to individual bl...

Page 11: ...Y PARTS CORRECTLY VII TROUBLESHOOTING Troubleshooting should only be performed by trained personnel Any potential electrical problems should only be checked by a licensed electrician All safety rules regulations and procedures MUST be followed Failure to follow proper procedures can cause property damage severe bodily injury and death DANGER PROBLEM CAUSE Excessive Vibration 1 Loose mounting bolts...

Page 12: ...aintenance 2 The blower should be supported under each corner of its base to allow it to breath Supports 2 x 4 s timbers or railroad ties should be placed diagonally under each corner 3 If the equipment is to be stored for more than three 3 months the entire blower assembly must be loosely covered with plastic but not tightly wrapped 4 Storage Maintenance A periodic inspection and maintenance log ...

Page 13: ... insulation resistance b DO NOT lubricate the motor bearings during storage Motor bearings are packed with grease at the factory c If the storage location is damp or humid the motor windings must be protected from moisture This can be done by applying power to the motor s space heaters IF AVAILABLE while the motor is in storage If the motor does not have space heaters storing it in a damp or humid...

Page 14: ...to the replacement free of charge of parts returned at Purchaser s expense F O B Seller s plant and found to be defective by the Seller IN NO EVENT WILL SELLER BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER IN CONTACT TORT NEGLIGENCE STRICT LIABILITY OR OTHERWISE INCLUDING WITHOUT LIMITATION DAMAGES FOR INJURY TO PERSONS OR PROPERTY LOST PROFITS OR REVENUE LOST SALES OR...

Page 15: ...1 For the parts drawing of all the standard components and specifications for the specific blower or fan that you have please contact our local Cincinnati Fan sales office for your area You will need to give them the serial number shown on the blower or fan nameplate so they can supply you the correct information Click on Contact a Sales Rep on our website for the name and contact information for ...