Unfortunately, the best hatch rates can be reached with which parameter combination is not known for different species yet. But Cimuka Research
Team is collecting data from our research center and customers for different APC application results and advises below details for Cooling for a Set
(clS) mode.
Note:
Cooling by a time (clt) mode is highly dependent on hatchery room conditions and the loaded egg amount in the model and only advisable to
use for temperature controlled hatchery rooms to reach same hatching results.
Active Periodic Cooling (APC) Parameters
Display
Factory settings
Chicken
Duck
Goose
Cooling mode
clF
oFF
cIS
On at 8th day
Off at 19th day
cIS
On at 8th day
Off at 25th day
cIS
On at 8th day
Off at 27th day
Cooling start time
cb
cof
con
con
con
Cooling cycle time
cPr
24 h
24
24
24
Cooling set point C ( set –adjusted data)
cSt
-8.0 C
-8.0
-8.0
-8.0
Cooling set point F ( set –adjusted data)
FSt
-15.0 F
-15.0
-15.0
-15.0
Waiting time in cooling set point
cth
20 min
10 min. 8th to 13th
20 min. 14th to 18th
10 minutes 8th to 15th
25 minutes 16th to 25th
10 min. 8th to 14th
20 min. 15th to 21th
40 min. 22th to 27th
Max cooling time
hct
120 min.
120 min.
150 min.
180 min.
Humidification*
chu
on
-/on
on
on
Humidification Time*
cht
10 min.
10
15
15
Max humidity during humidification*
chh
80 RH%
80
80
80
Cooling fan activation**
cFn
on
on
on
on
* only for models equipped with humidifier
**only for models equipped with cooling fan
CAUTION!
Don’t forget to off Active Periodic cooling function during hatching period. Cooling in last 2-3 days of incubation results
with bad hatching rates and chick loses.
CAUTION!
Changing cooling mode (cIF) or cooling cycle time (cPr) parameters in APC menu resets periodic cooling cycle time (cPr).
CAUTION!
In clS mode, time to reach cooling set point cSt (Fst) is highly dependent to room temperature. For very low set points,
system could not reach cooling set point. For such situations, system finalizes cooling at max cooling time (hct).
PD SERIES