OPERATION
WELDSKILL 200AC/DC INVERTER
Manual 0-5206
4-7 Operation
Programming Parameter
Adjustment Device
Display
Hot Start
This parameter operates in all weld modes
except LIFT TIG mode and is used to heat up
the weld zone in TIG modes or improve the
start characteristics for stick electrodes the
peak start current on top of the BASE (WELD)
current.
e.g. HOT START current = 130 amps when
BASE (WELD) = 100 amps & HOT START = 30
amps
Amps
70
0 to 70A (max 170A weld current)
Base Current
This parameter sets the TIG WELD current
when PULSE is OFF. This parameter also sets
the STICK weld current.
Amps
170
5 to 170A (DC STICK mode)
10 to 170A (AC STICK mode)
Arc Force (STICK Mode only)
Arc Force is effective when in Manual Arc
Mode only. Arc Force control provides and
adjustable amount of Arc Force (or "dig")
control. This feature can be particularly
beneficial in providing the operator the ability
to compensate for variability in joint fit-up in
certain situations with particular electrodes. In
general increasing the Arc Force control toward
100% (maximum Arc Force) allows greater
penetration control to be achieved.
Volts
VOLTS
SECONDS
PERCENT (%)
FREQ (Hz)
0 to 100%
Table 4-2
4.03 WELDSKILL 200AC/DC – LIFT TIG and HF TIG Programming Mode
Press the PROCESS button to select LIFT TIG or HF TIG mode.
Press the MODE switch to goggle between AC and DC welding output.
The Programming LED's are always active. Press FORWARD or BACK to cycle through available programming
functions.
Use the Multi Function Control to adjust the parameter selected.
100
Summary of Contents for WeldSkill 200AC/DC
Page 6: ...WARRANTY TERMS INSIDE REAR COVER GLOBAL CUSTOMER SERVICE CONTACT INFORMATION REAR COVER ...
Page 16: ...WELDSKILL 200AC DC INVERTER INTRODUCTION Introduction 2 2 Manual 0 5206 Notes ...
Page 40: ...Theory of Operation 5 2 Manual 0 5206 WELDSKILL 200AC DC INVERTER THEORY OF OPERATION Notes ...
Page 58: ...Troubleshooting 6 18 Manual 0 5206 WELDSKILL 200AC DC INVERTER TROUBLESHOOTING Notes ...
Page 82: ......
Page 84: ......