OPERATION
WELDSKILL 200AC/DC INVERTER
Manual 0-5206
4-5 Operation
18. Digital Ammeter
The digital amperage meter is used to display both the pre-set current and actual output current of the
power source.
At times of non-welding, the amperage meter will display a pre-set (preview) amperage value. This value
can be adjusted by varying the multifunction control when the Programming Parameter Indicator light
shows BASE CURRENT.
When welding, the amperage meter will display actual welding current.
Should a remote device be connected the maximum setting of the power source will be determined by the
respective front panel control, irrespective of the remote control device setting. As an example, if the output
current on the power source front panel is set to 50% and the remote control device is set to 100%, the
maximum achievable output from the unit will be 50%. Should 100% output be required, the respective
power source front panel control must be set to 100%, in which case the remote device will then be able
to control between 0-100% output.
NOTE
If a fault condition occurs for either Thermal Overload or Primary Circuit Overload then “Err” is
displayed on this meter. (Refer to section 3.08.6 Fault Indicator for further detail)
19. Digital Voltmeter / Parameter meter
The digital volt meter is used to display the actual output voltage of the power source. It is also used to
display Parameters in Programming Mode.
Depending on the Programming Parameter selected, the status indictor adjacent to the volt meter will
illuminate to show the units of the programming parameter.
When welding, the volt meter will display actual welding voltage.
NOTE
If a fault condition occurs for either Thermal Overload or Primary Circuit Overload then an “001” is
displayed on this meter. (Refer to section 3.08.6 Fault Indicator for further detail)
20. On / Off Switch (not shown)
This Switch is located on the rear of the Power Source and turns mains power off and on.
!
WARNING
When the front digital displays are lit, the machine is connected to the Mains supply voltage and
the internal electrical components are at Mains voltage potential.
21. Shielding Gas Inlet
The Shield Gas Inlet is a 5mm nipple suitable for connection of a gas hose to a regulated Shielding Gas
Supply. The Shielding Gas inlet is located on the rear of the Power Source.
21. Cooling Fan
The WeldSkill 200AC/DC is fitted with a cooling fan that will operate continuously when the On/Off switch
on the rear panel is switched to the On position.
Summary of Contents for WeldSkill 200AC/DC
Page 6: ...WARRANTY TERMS INSIDE REAR COVER GLOBAL CUSTOMER SERVICE CONTACT INFORMATION REAR COVER ...
Page 16: ...WELDSKILL 200AC DC INVERTER INTRODUCTION Introduction 2 2 Manual 0 5206 Notes ...
Page 40: ...Theory of Operation 5 2 Manual 0 5206 WELDSKILL 200AC DC INVERTER THEORY OF OPERATION Notes ...
Page 58: ...Troubleshooting 6 18 Manual 0 5206 WELDSKILL 200AC DC INVERTER TROUBLESHOOTING Notes ...
Page 82: ......
Page 84: ......