![CIGWELD 300Pi Operating Manual Download Page 31](http://html1.mh-extra.com/html/cigweld/300pi/300pi_operating-manual_2607019031.webp)
TRANSTIG 300Pi
Manual 0-5309
3-13
INSTALLATION, OPERATION AND SETUP
Pulse Width
This parameter sets the percentage
“on” time of the PULSE FREQUENCY
for BASE weld current when in DC
PULSE operating mode.
Range is 15 to 80%. Factory default
is 50%.
(Pulse)
A-12109
Pulse Frequency
This parameter sets the PULSE
FREQUENCY when in DC PULSE
operating mode.
Range is 0.5 to 500Hz. Factory default
is 100Hz.
(Pulse)
A-12110
Down Slope
This parameter operates in TIG modes
only and is used to set the time for
the weld current to ramp down to the
crater current. This control is used to
eliminate the crater that can form at
the completion of a weld.
Range is 0.0 to 25.0 seconds. Factory
default is 3.0 seconds.
(Pulse)
A-12111