atmospheric absorption will occur. High humidity will also raise the
absorption level.
Recording/Playback of a call:
Push the button Rec (E) in HD mode to record a call.
The recording will start immediately and the memory LED on the upper left
side of the display will begin to flash. The signal of the HD detector will
now be recorded with 44.1 kHz sampling rate in 8 bit mode. The recording
length is ~3 seconds. You cannot switch to another detector mode during
the recording. When the recording is finished the memory LED will be
constantly on.
The push button Rec (E) will now work as a playback button. Press it for
less than 3 seconds to playback the call. The display now shows the
frequency that was selected at the time the recording was made. This
frequency is taken at the start of the recording. Adjustments made while
the recording was running are not displayed.
Deleting a recording:
To delete a recording hold the Rec Button (E) for 3 seconds or longer. The
detector will confirm the deletion by showing 'del' in the display. The
memory LED will switch off and the detector is now ready for a new
recording. Only one recording at a time can be held.
The recording is saved in a volatile memory and will also be deleted if the
detector is switched off.
Switching the detector off:
Press the On/Off button for 3 seconds or longer. The device will
confirm this with 'OFF' on the display.
Battery lifetime:
The detector is fully functional until the battery reaches 6.7 volts. When
the battery life is at an end with 7.2 volts or less the display shows 'LBAT'
when switching on. Nevertheless the detector stays operable.
When the battery reaches 6.7 volts, the HD reception will begin to fade.
Please exchange the battery.
Please use only alkaline 9 volt batteries or 8.4 volts (7 cells) or 9.6 volts
(8 cells) NiMh rechargeable batteries.