RBW205

            

Product Description

Item

Technical Data

RBW205

  

Room control module with room temperature sensor, setting of room tem-
perature setpoint made using knob (with LED indicator) with presence but-
ton, buttons for fan control (higher/lower), button for automatic fan mode, 
each with LED indicators

Nominal voltage

DC 12 V ± 20%, 0.72 W

Power consumption

0.6 W (LEDs switched off), 0.72 W (LEDs switched on)

Measured value

Room temperature of spaces in homes or commercial premises

Measuring system

Integrated digital room sensor

Controls

Knob for setting room temperature setpoint

Keys:

Fan control level increasing: Fan on, increased speed

Fan control level decreasing: Decreased speed, fan off

   Fan in automatic mode (fan speed specified by controller)

Presence button (power save button): Switch to present or absent

Indicator

Red LED: higher room temperature setpoint

Blue LED: lower room temperature setpoint

Green LEDs: Feedback for fan level , automatic mode, presence button 
(present)

Interfaces

CAN bus, 4-wire terminal or RJ9

Measuring range

0 °C to 50 °C

Relative measuring accu-
racy

0.1 K

Housing

Plastic housing, RAL 9010 (pure white)
Other colors on request

Protection class

III

Degree of protection

IP30

Ambient temperature

0 °C to 50 °C

Ambient humidity

During operation: 20% to 80% r.h.; non-condensing
Out of operation: 5% to 90% r.h.; non-condensing

Installation

Screw mounting on standard flush-mounted box 

Weight

0.1 kg

Dimensions

WxHxD mm 90 x 90 x 32,5
Depth in wall 9.5

Summary of Contents for RBW205

Page 1: ...N Variant with a graded range of functions are available Set room temperature manual and automatic fan control presence button present absent Content Page Important Information Regarding Product Safet...

Page 2: ...with local regulations Mounting installation and commissioning work on the devices may only be carried out by qualified technicians Qualified technicians are persons who are familiar with the describe...

Page 3: ...speed Fan control level decreasing Decreased speed fan off Fan in automatic mode fan speed specified by controller Presence button power save button Switch to present or absent Indicator Red LED highe...

Page 4: ...Page 4 10 Product Description RBW205 Technical brochure NA 14 52A Dimensions 90 0 23 0 16 0 90 0 9 5 50...

Page 5: ...onnection 12V C RJ 0 V C 17 18 19 20 59 60 57 58 18 17 L1 N 2 1 Y4 0V 7 8 6 5 4 11 10 12 9 32 33 34 35 30 31 26 27 28 29 24 25 50 51 B A LON Y2 24V 0V RJ 230V 10 A K10 K2 K1 24V 230V K7 K8 K9 3 A 2 A...

Page 6: ...rried out by qualified technicians when the power is switched off Choose an installation location that is subject to the air flow of the room to ensure that the room controller can quickly and accurat...

Page 7: ...Page 7 10 Technical brochure NA 14 52A RBW205 Product Description Installation on a standard flush mounted box 4 wire connection to terminal 1 2 3 4 5 6...

Page 8: ...e by degrees C to full intensity 3 C in comparison to the average value Energy saving mode If you leave the room for a longer period of time switch the presence button to Absent LED OFF The energy sav...

Page 9: ...f room control module RCN This triggers the service PIN in room controller RCN internally This is indicated by a service LED 4 on the top part of the housing on the room control modules that lights up...

Page 10: ...Page 10 10 Product Description RBW205 Technical brochure NA 14 52A...

Reviews: