5 - ELECTRICAL CONNECTIONS

Positioning switches

Inside each box slave BOX ELEC Eco + is an internal regulator that collects and interprets the instructions of the master controller.
For the proper functioning of the regulation it is imperative to position the switches (symbolized in black) of this internal regulator 

as below:

HELIOTHERME n° 1

HELIOTHERME n° 2

HELIOTHERME n° 3

HELIOTHERME n° 1

HELIOTHERME n° 2

HELIOTHERME n° 3

Switch 3 is not used (nothing will happen if its position is changed).

Switch 4 must be set to ON.

Correct positioning of these switches, while properly setting parameter 29 (see page 8), you will see precisely the master controller 

of the display on which HELIOTHERME:

 

-

Engine failure is present

 

-

A defect is present electric battery

 

-

A failure to communicate with the master controller is present

BOX ELEC Eco+ 

EN-22  

Summary of Contents for BOX ELEC Eco+

Page 1: ...BOX ELEC Eco 08 2019 XX7570605 00 Manuel de r gulation C o n t r o l m a n u a l...

Page 2: ...ocument sont fournies titre purement indicatif et ne font pas partie d une quelconque offre de vente ou d un contrat Le fabricant se r serve le droit de changer la conception tout moment sans avis pr...

Page 3: ...QUE 6 4 ENCOMBREMENTS DES COMPOSANTS 6 5 RACCORDEMENTS ELECTRIQUES 7 6 PRINCIPE DE FONCTIONNEMENT 9 7 PARAMETRES UTILISATEURS 9 8 PARAMETRES INSTALLATEUR 10 9 PROGRAMMATION HORAIRE 12 10 MESSAGE D ERR...

Page 4: ...fonction de la demande en apport thermique de votre b timent Vous chaufferez au plus pr s de vos besoins Une utilisation citoyenne de votre parc d a rothermes gr ce l horloge interne configurable hebd...

Page 5: ...cul e selon ce mode Pour revenir la configuration d usine maintenir la touche de d filement des menus gauche ainsi que la touche avant la mise sous tension du coffret La r gulation affichera la suite...

Page 6: ...EC Eco Indice de protection IP 65 Alimentation TRI 400V Neutre 50 Hz 4 ENCOMBREMENTS DES COMPOSANTS Contr leur ma tre Dimensions hors tout sans les presse toupes Entraxes de fixation Coffret esclave B...

Page 7: ...n batterie lectrique en mode HIVER Ventilation seule en mode ETE En mode HIVER l arr t du groupe motoventilateur est temporis dur e r glable au param tre 25 afin d viter tout risque de surchauffe et d...

Page 8: ...ous HELIOTHERME n 1 HELIOTHERME n 2 HELIOTHERME n 3 HELIOTHERME n 1 HELIOTHERME n 2 HELIOTHERME n 3 Le switch 3 n est pas utilis sa position n influence rien Le switch 4 doit imp rativement tre sur ON...

Page 9: ...de fonctionnement de la r gulation Unit WintEr hiver utilisation en chauffage SuMMEr t utilisation en ventilation seule Mini Maxi D faut WintEr Incr ment 01 For age Permet l utilisateur de forcer le m...

Page 10: ...T de consigne est sera longue atteindre Plus la pente est courte proche de 1 C plus l enclenchement des tages de puissance de la batterie lectrique est r actif Inconv nient syst me proche d une r gul...

Page 11: ...on l arr t de la batterie lectrique Cette temporisation permet d vacuer toutes les calories mises par inertie apr s l arr t de la batterie lectrique Mini 1 Maxi 20 D faut 2 Incr ment 1 28 Nombre d tag...

Page 12: ...CFt 06 00 ECO 2 Programmation plage Je 2 Je 1 23 59 ECO 22 00 H GL 1 Programmation plage Ve 1 00 00 Ve 2 CFt 06 00 2 Programmation plage Ve 2 Ve 1 23 59 ECO 22 00 1 Programmation plage Sa 1 00 00 Sa...

Page 13: ...et coffret esclave BOX ELEC Eco Pr sence d un d faut de communication entre le contr leur maitre et un des coffrets esclaves BOX ELEC Eco r gulateur interne HS d connection Le num ro pr sent sur l af...

Page 14: ...11 SCHEMA DE RACCORDEMENT BOX ELEC Eco FR 14...

Page 15: ...FR FR 15 BOX ELEC Eco...

Page 16: ...rations in this document are for illustrative purposes only and not part of any offer for sale or contract The manufacturer reserves the right to change the design at any time without notice BOX ELEC...

Page 17: ...SCRIPTION OF COMPONENTS 19 3 ELECTRICAL SPECIFICATIONS 20 4 DIMENSIONS OF THE COMPONENTS 20 5 ELECTRICAL CONNECTIONS 21 6 OPERATING PRINCIPLE 23 7 USER SETTINGS 23 8 INSTALLER SETTINGS 24 9 TIME SCHED...

Page 18: ...equirements Heat as precisely as possible in accordance with your needs Une utilisation citoyenne de votre parc d a rothermes gr ce l horloge interne configurable hebdomadairement selon 4 modes d util...

Page 19: ...Frost Protection and the setpoint calculated for it To return to factory settings hold the left menu scroll key and the key before powering the enclosure The control display after this reset the mess...

Page 20: ...rotection IP 65 Food TRI 400V Neutral 50 Hz 4 DIMENSIONS OF THE COMPONENTS Master controller Overall dimensions without cable glands Center distance of fastening Slave box BOX ELEC Eco Overall dimensi...

Page 21: ...or heat supply of the building ventilation and electric battery WINTER fashion Fan only in SUMMER mode WINTER mode stopping the fan assembly is delayed adjustable parameter 25 to prevent overheating a...

Page 22: ...as below HELIOTHERME n 1 HELIOTHERME n 2 HELIOTHERME n 3 HELIOTHERME n 1 HELIOTHERME n 2 HELIOTHERME n 3 Switch 3 is not used nothing will happen if its position is changed Switch 4 must be set to ON...

Page 23: ...o set the control box s operating mode Unit WintEr used for heating SuMMEr ventilation only Min Max Defaut WintEr Increment 01 Override Allows the user to override the control mode being used Unit Off...

Page 24: ...ogressive Disadvantage the set T is to be a long reach The steeper the slope is short close to 1 C more engagement of the power stages electric battery is reactive Drawback system close to a regulatio...

Page 25: ...the electric battery This delay serves to remove all the calories emitted by inertia after stopping the electric battery Min 1 Max 20 Defaut 2 Increment 1 28 Number of electric power stage controlled...

Page 26: ...06 00 2 Programming range Fri 2 Fri 1 23 59 ECO 22 00 1 Programming range Sat 1 00 00 Sat 2 CFt 06 00 2 Programming range Sat 2 Sat 1 23 59 ECO 22 00 1 Programming range Sun 1 00 00 Sun 2 CFt 06 00 2...

Page 27: ...ication fault between the master controller and a Eco ELEC BOX slave unit has been detected internal controller inoperative disconnection etc The number displayed indicates the Eco ELEC BOX slave unit...

Page 28: ...11 WIRING DIAGRAM BOX ELEC Eco EN 28...

Page 29: ...EN EN 29 BOX ELEC Eco...

Page 30: ......

Page 31: ......

Page 32: ...6 728 480 R C S Bourg en Bresse B 545 620 114 Document non contractuel Dans le souci constant d am liorer son mat riel CIAT se r serve le droit de proc der sans pr avis toutes modifications techniques...

Reviews: