CIAS Elettronica S.r.l.
Ed. 1.6
Installation Manual
Page 44 of 46
MICRO-RAY
Non indicated Application default SET:
Application
Type
number
Tipo di applicazione
Filtro per
disturbi
ambientali
Tempi
Interruzione
4
Open areas
1 = HIGH
50mS
3
Corridors delimited on both sides
1 = HIGH
75mS
1
Anti-crawling / Anti-climb Advanced
0 = LOW
75mS
4.1.2.2 Read/Write Barrier Number
Carrying the function switch SW1 to position 8, it is possible to read and/or set the barrier
number.
Write barrier number:
•
Select a number from 01 to 31 on the appropriate switches SW2 (tens) and SW3
(units).
•
Press the button S3, to confirm its acquisition
Read the assigned barrier number:
•
Turn the SW2 switch until the red LED (D9) is on
•
Turn the switch SW3 until the red LED (D8) is on
The number from 01 to 31 represented on switches SW2 (tens) and SW3 (units), corresponds
to the barrier number currently assigned to the barrier.
Note: The barrier number must be the same as the one set on the corresponding TX ray and the
same for all the rays of the same barrier.
4.1.2.3 Read/Write Masking threshold
Carrying the function switch SW1 to position 6, it is possible to read and/or set masking.
Select Masking:
•
Select a number from 00 to 02 on the appropriate switches SW2 (tens) and SW3
•
Press the button S3, to confirm its acquisition and use
Read set Masking;
•
Turn the SW2 switch until the red LED (D9) is on
•
Turn the switch SW3 until the red LED (D8) is on
The number from 00 to 02 represented on the SW2 (tens) and SW3 (units), corresponds to
the masking threshold currently assigned to the ray.
Number
Masking Threshold
SW2
SW3
0
0
Low
0
1
Middle
0
2
High (default)
4.1.2.4 Walk-Test
Setting the function switch SW1 to position 4, it is possible to carry out the Walk-Test. The ray
will work with the set parameters and once the ray is interrupted, the buzzer present inside the
Rx circuits will be activated with a continuous sound.