![cias MICRO-RAY Series Installation Manual Download Page 27](http://html1.mh-extra.com/html/cias/micro-ray-series/micro-ray-series_installation-manual_2606604027.webp)
CIAS Elettronica S.r.l.
Ed. 1.6
Installation Manual
Page 26 of 46
MICRO-RAY
2 INSTALLATION
Column assembly on the TOWER BASE
Once the column cover is open, align the lower part with the plug of the TOWER-BASE steel base
that will be fixed to the ground (see Fig. 1 and 2). At this point insert the special plug in the column
only after having positioned the locking L-shaped bracket (Fig. 3). After this you can fix the
supplied screws (Fig. 4).
In the upper part of each column there are two serial switches (tamper). The one on the side
signals the removal of the upper cover. The central one signals the pressure on the lid and is
therefore indicated to reveal override attempts.
Note: be sure to
connect to ground
the metallic structure
of the tower
Figure 5
Anti-opening
Override
Fig. 1
Fig. 2
Fig. 3
Fig. 4