SET –UP BUTTON FOR ALIGNEMENT AND SETTING
N° Symbol
Function
1
S3
Button to accept data in alignment operation and to write
parameter in setting operations
RECEIVER FUNCTION SWITCH SW1
N° Symbol
Function
SW1
FUN
Position 1 = Barrier alignment
Position 2 = acquisition, of the installation values (Channel number
and AGC Voltage)
Position 3 = Prealarm thresholds Read/Write
Position 4 = Alarm thresholds Read/Write + Walk-Test
Position 5 = Masking thresholds Read/Write
Position 6 = Upper Prealarm thresholds Read/Write (FSTD)
Position 7 = Lower Prealarm thresholds Read/Write (FSTD)
Position 8 = Barrier number Read/Write
Position 9 = Monitor thresholds Read/Write
Position 0 = Working Phase
PARAMETERS AND BARRIER NUMBER READING AND SETTING
SWITCHES SW2- SW3
N° Symbol
Function
SW2
DEV10 Decimal rotary switch to read or to set parameters during the
alignment operations (tens column)
SW3
DEV1
Decimal rotary switch to read or to set parameters during the
alignment operations (units column)
3.2
Equipment Connection to the Power Supply
3.2.1 Connection to the Power Supply
The units must be powered with DC voltage, nominal value is 13,8 V
.
The connection between unit and the power supply must be realised with cables of correct
section, the cables section must be computed keeping in account connection length and unit
current absorption. For the very long connection case we suggest the use of a supplementary
power supply. For the power supply connection (13,8 V
e GND ), to make connect pin 1 and 2
on the terminal strep MS2 of the Tx and Rx circuit.