3.3.3 Power supply and Battery recharge circuit
MS 1
MS 2
2
1
Cn1
GND
MPR
13,8V
MS 3
GND
MPR
13,8V
1
2
3
1
2
TERMINAL BLOCK MS1 POWER SUPPLY
Term Symbol
Function
1
19 V~
Alternate Alimentation Input (19-24 V~) or (24V )
2
19 V~
Alternate Alimentation Input (19-24 V~) or (24V )
TERMINAL BLOCK MS2 POWER SUPPLY
Term Symbol
Function
1
13,8V
Positive for battery (+13,8V ) limitation 600 mA
2
GND
Negative for battery
TERMINAL BLOCK S3 POWER SUPPLY
Term Symbol
Function
1
13,8V
Positive for power supply circuit (+13,8V )
2
GND
Negative for Power supply circuit
3
MPR
Positive for main presence (+14,6V )