5.8 – ELECTRICAL CONNECTION – REMOTE CONDENSING UNIT
In case the display cabinet has a remote condensing unit, the electric control panel is supplied separately; in case the display cabinet is without condensing
unit, the machine can be supplied without external control panel. However the electrical connection has to be made in the point indicating in the pic. 5.3.
In this point 5 connecting terminal are not fixed; they are numbered and represent:
1-2
Electrical supply
3-4
Compressor switch
5-6
Defrosting switch
Ground connecting terminal
5.9. IDRAULIC CONNECTION
In case the display cabinet has an internal condensing unit by air, it is not necessary any water system connection.
In case the display cabinet has a dipper well, it is necessary make the connection of its water outlet with the main water drain outlet; besides it is
necessary set a load water tube to the dipper well, to the operator side, to the right or to the left, according to customer’s choice.
In case the display cabinet has condensing unit working fully or partially by water, it is necessary to connect the load water tube (this is the tube with
thermo insulation) with the unload water tube(this is the tube without thermo insulation), of condenser working by water, to the water line
5.10.
IDRAULIC CONNECTION
-
REMOTE CONDENSING UNIT
In the case then display cabinet has a remote condensing unit, it is necessary make the connection of defrosting water outlet with the main water
drain outlet. At the base of cabinet you can find a female pipe-fitting with a rapid receptacle for a tube Ø 32 mm
pic.5.3