THE PRODUCT RESULTS CONFORM TO THE FOLLOWING STANDARDS REQUIREMENTS:
STND SPECIFICATION
TITLE
EN50081-1
EMISSION STND
Part.1: residential, commercial and light industry
EN50082-1
IMMUNITY STND
Part.1: residential, commercial and light industry
EN60335-1
SAFETY OF HOUSEHOLD AND SIMILAR ELECTRICAL
APPLIANCES
CONFORMITY WAS BASED ON EMC PERFORMANCE TESTS CONDUCTED ON SAMPLE RUNNING IN THE
DESIGNED WORKING CONDITIONS AS FOR ITS FUNCTIONAL PROJECT, IT MEETS 89/336/EEC AND 73/23
EEC REQUIREMENTS.
DATE
21 May 1999
COMPANY MANAGEMENT
2
Installation
2.1
General instructions
!
Do not install the device at places exposed to the bad weather or to the extreme
temperatures.
!
The central unit is protected from the opening, but the installation in a safe place is a
greater protection of the device.
!
For a strong and safe fixing, it needs making sure the wall surface is plane.
!
Fixing the device by the four fishers included in the central unit and no replacing them with
others of more small size.
!
Fixing the central unit at a height that allows an easy access to the frontal panel.
!
The central unit must be connected with an alarm system according to CEI 79-3 Standard
or similar.
2.2
Power supply
It ‘s important to know that the entire system is powered exclusively by the 12V 7,5Ah lead
battery inside of the burglary central unit; the lead battery is constantly in charge by the AL5
power supplier/battery connected to the 230V~ main power supply.
20
1.3
Technical features
!
Operating voltage:
230V~ ±10% 50Hz
!
Maximum current absorption:
140mA
!
Service output voltage:
!
Maximum current supplied on services output:
650mA
!
Fuse on services output voltage
F type 1A
!
Maximum current supplied on sirens output
3A (connected to the battery)
!
Sirens output fuse:
Tipo F 3,15A
!
Maximum current supplied by power supplier AL5:
1A
!
Min operating temperature:
5±2°C
!
Max operating temperature:
40±2°C (relative humidity. 93±2%)
!
Box protection level:
IP30
!
Buffer battery:
12V7Ah
!
Fuse on primary of the power supply:
F type 250mA
!
Fuse on secondary of the power supply:
F type 1A
!
Central unit dimensions:
280x230x95mm
!
Insulation class:
!
13V
!
±5%
Prestation level:
1°
21
HiLTRON
S.r.l.
®
PROGETTAZIONE E PRODUZIONE APPARECCHIATURE ELETTRONICHE
PROTEC4 - User’s manual
Installation
CONSTRUCTOR:
HiLTRON S.r.l.
ADDRESS:
Circ. Est. di Napoli compls. Lemar 80026 Casoria (NA)
TRADE MARK:
PRODUCT CODE:
PROTEC4
PRODUCT DESCRIPTION:
4 ZONES BURGLARY CENTRAL UNIT
DECLARATION OF CONFORMITY
230V~
50Hz
main power supply
Switch
WARNING!
The main power supply 230Vac has to be connected to the power supplier/battery
charger AL5 by two 1,5mm² double-isolation wires coming from a sectioning switch(i.e.
a magneto-thermic protection switch) used exclusively for the burglary central unit.
Inside of the central unit positioning orderly the two wires, locking them by wrappers.