28
29
4
Operating
4.1
Front panel description
4.2
System enabling
4.2.1
Enabling by the front panel key switch
!
Verify that the zone status LEDs and are turned off.
If they’re switched on it’s necessary to close the doors and windows relative to the zone
signalled opened. It’s also possible that the zone signalled opened could be the one
relative to the volumetric detectors; in this case the exiting time will allow to exit the
protected area without activating the alarm.
!
Turn the key switch in the “ON” position.
!
The green LED “USCITA” starts blinking indicating the exiting time, in which to leave the
protected areas.
!
When the exiting time is finished, the green LED "USCITA" turns off indicating that the
system is enabled.
4.2.2
Enabling by other command system
If an electronic key system, a proximity key system, or an electronic keypad system is
installed outside of the protected areas, it's necessary to leave the key switch ALWAYS in the
“ON” position.
All the SKI connector for the electronic
key, the PXR reader for the proximity key
and the KBC, KBM and KBT keypads have
two LEDs, one green and one red,
indicating the central unit status (see table
beside).
To enable the system:
!
Verify that the red LED is turned off.
If it's turned on, it's necessary to close
the opened doors or windows relative
to the zone that is signalled opened in
the central unit.
!
Insert the electronic key, or approach
the proximity key to the reader, or digit
the code on the keypad.
!
The green LED turns off indicating that
the system is enabled.
3
4
1
8
8
1
PROTEC4 - User’s manual
Operating
GREEN
LED
RED
LED
BOTH
ON
System
disabled
Opened
zone/s
Alarm
memory
OFF
System
enabled
Closed
zones
FLASH
System
disabled
Excluded zone
Exiting
time
4
7
5
8
3
1
2
9
10
6
11
12
Key switch
Allows to enable / disable the system. If there's
an electronic key or another command system ,
this switch has always to be turned on the
“INSERITO” position.
"RETE" red LED
on
presence of main supply
off
absence of main supply
"ALLARME" yellow LED
on
during the entering time
or in alarm condition
blinking
ALARM MEMORY
"USCITA" green LED
on
system disabled
blinking
during the exiting time
off
system enabled
"MEMORIA ALLARME" button
pressed
ALARM MEMORY
visualization
released
zone status
visualization
On system disabled, by pressing this button, the
blinking zones status control LEDs , e
indicate the ALARM MEMORY (i.e. the zone
that caused the alarm).
24h zone status control LED
on
zona aperta
off
zona chiusa
blinking
zona autoesclusa
Zone1, zone 2, zone 3 status control LED
on
zona aperta
off
zona chiusa
*blinking
ALARM MEMORY
*
with the button pressed
.
Zones exclusion/inclusion buttons
On system disabled, it is possible to exclude a
zone by pressing the relative button; the LED
upstanding the button starts blinking. The zone
protection willnot be included during the system
enabling.
7
8
9
5
10
11
12
1
2
3
4
5
6
7
8
9
GREEN
LED
RED
LED