Generally speaking, the following minimum cable cross-sectional areas must be adhered to:

2

100-230Volt

1.5mm or more

2

0-24Volt

0.5mm or more

Tips: Bell wire is often problematic in practical use because it loses too much voltage if long lengths of wire are used.
Segregate the cables in cable trunking, i.e. motor cable and light barrier cable, especially in the case of key-operated switches and ON switches
(from the house wiring system) to prevent interference where long lengths of cable are used.

OVERVIEW OF CONNECTIONS

Motors: connect the control unit exactly in accordance with the overview of connections. The gate/door wing, which opens first,  must be motor 1
(M1) and when it first moves it must OPEN the gate/door. If it closes the gate/door, swap terminal 6 with terminal 8 or, in the  case of motor 2
(M2), swap terminal 9 with terminal 11.

The capacitor supplied as standard must be installed between cables 6 and 8 and 9 and 11 (for space reasons, the capacitor can  also be installed
in a distribution box). Make sure that its terminals are properly connected and that there is a good electrical connection. The  capacitor determines
the force which the motor subsequently 

TECHNICAL SPECIFICATIONS:

Operating cicles 

16cicles/h 

Nominal thrust 

250N 

Protection class

Power supply voltage 

230Vca ±10% 50Hz 

Normal current absorption 

1,3A

Power 220W 

Condenser

5?F 

Thermo-protection

140° 

Geared-motor speed

1400rpm 

Rod max lenght

300mm (ECO300)

400mm (ECO400)

Max hing lenght 

2,5m (ECO300)

3,5m (ECO400)

Max weight of hing 

250kg 

Maximum speed rod 

17mm/s (ECO300)

13mm/s (ECO400)

Box protection level 

IP44 

Operating temperature 

-20°C ÷ +55°C 

6

Sede legale, comm. ed amm.va: Via Caserta al Bravo, 218 - 80144 NAPOLI Tel: 

0039.081.705.09.12 pbx - Fax: 0039.081.705.01.25 - e-mail: [email protected]

 Declaration            of conformity

to the Standards of the Council of the European Union

è conforme ai requisiti delle direttive:

EMC 89/336 CEE    in merito alla compatibilità elettromagnetica

BT 73/23 CEE    in merito alla bassa tensione

del Consiglio dell'Unione Europea.

Le dichiarazioni di conformità ai requisiti sono depositati presso la:

Il dispositivo va installato dove e come descritto nella documentazione; 

la casa costruttrice declina ogni responsabilità per danni arrecati a cose o persone 

dovuti ad una sua diversa o errata installazione, o ad un suo improprio utilizzo.

it is in compliance with requirement of the directives: 

89/336 EMC the EEC    respect to 73/23 electromagnetic compatibility 

BT the EEC    respect to the low tension 

of the Council of the European Union.

The declarations of conformity to requirement are deposited at:

The has to be installed where and as described in the documentation; 

the manufacturer declines any responsibility for damages brings to things 

or persons due to wrong installation, or to an improper use of it.

Sede legale, comm. ed amm.va: Via Caserta al Bravo, 218 - 80144 NAPOLI Tel: 

0039.081.737.22.77 pbx - Fax: 0039.081.736.04.59 - e-mail: [email protected]

HiLTRON S.r.l.

Cap. soc. € 102.774,92 int. vers.

Iscr. trib. NA 3865/87

P.IVA IT 05253440639

C.C.I.A.A. di Napoli 436062

ECO300 / ECO400

Motoriduttore 230Vca per anta da 2,5 / 3,5mt

Dichiarazione          di conformità 

alle direttive del Consiglio dell'Unione Europea

Si certifica che il prodotto con marchio:

CIA Trading S.r.l.

Cap. soc. € 102.774,92 int. vers.

Iscr. trib. NA 3865/87

P.IVA IT 05253440639

C.C.I.A.A. di Napoli 436062

It is certified that the product with brand:

230Vac geared-motor for 2,5mt / 3,5mt hinged gate

 

Summary of Contents for ECO300

Page 1: ...ECO300 230Vac geared motor for 2 5m hinged gate ECO400 230Vac geared motor for 3 5m hinged gate Installation Manual...

Page 2: ...ease remove any locks fitted to the gate in order to prevent damage to the gate It is important to make sure that the gate always runs smoothly Gates which stick or jam must be repaired immediately Em...

Page 3: ...down to the switch on temperature The outdoor temperature and the gate are important parameters that affect the actual operating time INSTALLATION CHECKLIST PREPARATIONS Check the carton contents and...

Page 4: ...ects the fittings and gate to extreme stresses Different opening angles cause one motor to reach its destination first but continues to run thereby forcing the gate up against the gate stop until the...

Page 5: ...be custom made if the gate hinges are fitted on the posts appropriately it is possible to influence dimensions A and B Before the final mounting dimensions are determined you should always check whet...

Page 6: ...tances For steel gates fixings should be welded on or through bolted When through bolting the gate use large washers or a plate on the other side The drive mechanism exerts an extremely high force on...

Page 7: ...signated NC normal closed or NO normal open NC contacts are closed and open NO contacts are open and close Humidity and water will destroy the control board Always make sure that water humidity and co...

Page 8: ...C 6 Sede legale comm ed amm va Via Caserta al Bravo 218 80144 NAPOLI Tel 0039 081 705 09 12 pbx Fax 0039 081 705 01 25 e mail info hiltron it Declaration of conformity to the Standards of the Council...