![CHUNLAN -B Service Manual Download Page 11](http://html1.mh-extra.com/html/chunlan/b/b_service-manual_2606426011.webp)
Exploded view & dismantling sequence of parts
- 9 -
3. Dismantling sequence of outdoor unit of RD23-B, FRD35-B and FRD50-B
(1) Remove 11
(2) Remove 8, 9
(3) Remove 14
(4) Remove 1
(5) Remove 10
(6) Remove 5, 6
(7) Remove 16
(8) Remove 2, 3
(9) Remove 15
(10) Remove 7
(11) Remove 12, 13
(12) Remove 4
(13) Remove 17
Annex: Dismantling sequence of typical parts
Outdoor electric assembly:
(1) Remove top cover assembly 11
(2) Remove handle assembly 9
(3) Remove left rear plate assembly 8
(4) Remove outdoor electric assembly 10.
Outdoors motor:
(1) Remove top cover assembly 11
(2) Remote handle assembly 9
(3) Remove front plate assembly 1
(4) Remove fan 5
(5) Remove connecting plug from motor 6 and remove the motor.
Outdoors compressor
(1) Remove top cover assembly 11
(2) Remove handle assembly 9 and left rear plate assembly 8
(3) Remove front plate assembly 1
(4) Remove large and small shutoff valves 3 and 2, and remove reversing valve 7
(5) Remove compressor cable and the compressor.
Summary of Contents for -B
Page 38: ...Main technical parameters 36 3 Value in is nominal value for auxiliary electric heating...
Page 43: ...Circuit diagrams 41 Chapter V Circuit diagrams I Circuit diagrams...
Page 44: ...Circuit diagrams 42...
Page 45: ...Circuit diagrams 43...
Page 46: ...Circuit diagrams 44...
Page 47: ...Circuit diagrams 45...
Page 48: ...Circuit diagrams 46...
Page 49: ...Circuit diagrams 47...
Page 50: ...Circuit diagrams 48...
Page 51: ...Circuit diagrams 49...
Page 52: ...Circuit diagrams 50...
Page 53: ...Circuit diagrams 51...
Page 54: ...Circuit diagrams 52...
Page 55: ...Circuit diagrams 53...
Page 56: ...Circuit diagrams 54...