
Trouble
Shooting
29
Check to see if Ambient tank is (25%)
full.
If clogged, it will prevent water flow.
(OLC Mesh / Medium Filter)
Check to see if water is flowing after
the Post Carbon Filter.
12-4 FILTRATION MALFUNCTION
Symptom
Water tanks do not get full.
Cause of Defect
1. Mesh clog 2. Defective Pump
3. Defective Sol V/V
4. Membrane clog
AS Procedure
1) If Mesh / Medium Filter are clogged: Clean or replace.
2) Check to see if water is coming out after the Post Carbon Filter.
a. Adaptor
b. Sol V/V
c. Booster Pump
d. Membrane Filter.
How to Diagnose
1
2
3
Cold water operates above (25%).
Check to see if water is purifying properly