Check Point
Procedure
1. In case of ice is not making in the morning and the
Ice Full LED is ON.
1) Check if it’s Micom
Rev.2 2) Switch to icom
Rev.3
1. CDS sensor recognizes that it is night time when if
surrounded illumination of the unit is below 3 lux
and
the unit stops making ice after maximum 4 times ice
making. When it stops making ice, the Ice Full LED
turns ON.
* Ice Full LED turns ON although the ice tank is still
empty.
2. Mi-com Rev.2 stops making ice for 8 hours after the Ice
Full LED turns ON.
3. Method to turn OFF the Ice Full LED
-
Press and hold the Ice dispensing button for 7 seconds
and more then the Ice Full LED will be turned OFF.
4. Mi-com Rev.3 stops making ice for 6 hours after the Ice
Full LED turns ON. However it makes ice continually
until the ice tank is full even if it is dark.
3-1 Ice Full LED
CDS Sensor