background image

CHP-5361DL

Read the user's manual thoroughly before using the unit.

Design and color may differ from the picture.

Unit appearance, specification, etc. are subject to change without
prior notice if necessary for improving unit performance.

The rated voltage of this unit is 220-240 V~ / 50 Hz only

User's manual

 

 

Summary of Contents for CHP-5361DL

Page 1: ...using the unit Design and color may differ from the picture Unit appearance specification etc are subject to change without prior notice if necessary for improving unit performance The rated voltage...

Page 2: ...Extended water dispensing space It is convenient to take water with any shape of bottle as height of water dispensing space is up to 25 cm Dual heating system Hot water is made by standby heating mode...

Page 3: ...each part 07 Installation cautions 08 Installation method 09 How to use carbonated water 10 14 Extract button for carbonated water 10 LED display for carbonated water 10 11 How to use carbonated water...

Page 4: ...it off dust water or etc on the power plug pin before connection Associated with the possibility for serious injury or death Danger Cautions are divided into 2 categories Danger and Caution Safety pre...

Page 5: ...of the appliance in a safe way and understand the hazards involved Do not install the unit in or around largely damp areas at a place near flammable materials or at a place exposed to rain or snow Th...

Page 6: ...s can cause a reduced performance system damage or overall trouble Associated with the possibility of injury property damage and reduced performance of unit Caution Safety precautions When taking ice...

Page 7: ...s is a result of the freezing point method 4 After the system power source is interrupted and then again restarted irregular ice may temporarily be served Associated with the possibility of injury pro...

Page 8: ...isplay Ice making display Ice full display Hot water selection touch button Carbonated water extract display and control panel Cold water selection touch button Ambient water selection touch button Ho...

Page 9: ...ngth of brine tube must be less than 118 3 m Otherwise water is not drained well When installing more than one unit water purifier shower softener etc tubes of source water brine water need to be inde...

Page 10: ...tion After 1 hour has passed from supplying the power check if water is coming out by pressing the water dispensing button Empty the water in the tank when WATER FULL lights on Install horizontally Sh...

Page 11: ...nated water Animation for water dispensing No water No gas LED display for carbonated water amount It is operated while making carbonated water Animation for carbonated water Extract button for carbon...

Page 12: ...o extract the carbonated water After extracting carbonated water small amount of water can be generated It is normal operation How to use carbonated water Water amount of each level Touch POWER No wat...

Page 13: ...is fixed properly by moving it up and down 1 Press the button in the bot tom of carbonated water tray 3 Hook the carbonated water tray to the groove and detach a hand from the drip tray to fix it 2 Pu...

Page 14: ...under back of the unit Set the gas concentration by controlling the lever After setting the concentration users can enjoy the carbonated water of desired concentration Lift the cylinder and turn to t...

Page 15: ...when extracting carbonated water When gas concentration is weak Replacement cycle of cylinder is varied depending on actual working condition Actual amount of gas might be different Gas can not be di...

Page 16: ...middle and down to select the HOT TANK HEATING OFF STANDBY HEATING Press the switch up and down to select the drain setting releasing C D Hot tank heating mode Hot water is always served Standby heati...

Page 17: ...Ding 3 Hot water operation ice dispensing function work when the setting of lock function is released Ice making function setting 1 Press ICE LOCK touch button for 10 seconds Press the ICE LOCK touch...

Page 18: ...s and the water is continuously dispensed If constant water is set but not taking water then the function will be automatically released after 10 seconds When dispensing the water continuously approxi...

Page 19: ...use the ambient water when the ambient water is chosen it will automatically convert to cold water mode Hot water dispensing mode If HOT hot water selection touch button is selected and the water dis...

Page 20: ...not served automatically When the unit stops dispensing hot water standby heating starts off automatically Standby heating Level Yellow Orange Red Level 1 Completion of standby heating Hot water temp...

Page 21: ...d In case the unit is not used for long period of time More than 4 days shut off the adapter Source water valve and pull out the power plug Do not touch the power plug with wet hands Fire or electric...

Page 22: ...n the rear of the unit The cold ambient water can be drained for 10 minutes by an auto drainage function And the cold ambient water can be drained as well through the water outlet 3 Drain the hot and...

Page 23: ...heck if cold ambient water is served after 40 minutes 11 Drain the newly purified water completely once and use it Wash your hands first and put on sanitary gloves Clean up the tank with soft cloth or...

Page 24: ...soft cloth or sponge by running water 3 Clean up the inside of carbonated water spout often by clean soft cloth Carbonated water tray Clean up the carbonated water tray with soft cloth or sponge by ru...

Page 25: ...nce Clean up water dispensing spout and water gutter on regular basis Do not throw away any liquid except water If there is the water throw it away and clean up once a week Filter replacement ACS prod...

Page 26: ...sed in a high temperature It efficiently removes a suspended solid rust debris in a first stage and it minimizes a decrease in a flow caused by a turbidity material And it eliminates chlorine trihalom...

Page 27: ...and shut down source water valve 5 minutes of flushing is necessary before filter replacement 6 Turn the filter to the right side to make straight line on replacement filter and standard point of fil...

Page 28: ...475 H mm Reciprocating type Wire condenser type Forced convection Thermistor Thermistor Bimetal Manual return Over heating prevention system Water level detecting system Water leakage stop valve Fuse...

Page 29: ...Stem Elbow Solenoid valve TCR Precarbon TCR Membrane TCR Postcarbon Water leakage valve Source water Drain water Brine water Drain sol pump Water level sensor This is not warranty period This ideal r...

Page 30: ...t served When taking cold water Cold water is being produced It takes about 40 minutes Wait until the water level of ambient water tank reaches at operating point for hot and cold water After given ti...

Page 31: ...30 Memo...

Page 32: ...Rev No 01 Rev No 00 2F NAIS B D 28 SAIMDANG RO SEOCHO GU SEOUL KOREA Postcode 06651 TEL 82 2 3019 5141 FAX 82 2 3019 5270 E MAIL goodeal chungho co kr HOMEPAGE http eng chungho co kr...