8. Sanitary Maintenance

Section

Details

Location

Environment

Installation

Water 

dispensing

spout

Ice dispensing

hole

Water gutter

Use

- The unit can be installed at low water pressure place within water quality

range.

- Cleaning up water dispensing spout once a week is recommended. If foreign

substance splashes onto water dispensing spout, wipe it off right away.

- Do not take water with your mouth and not let used cup touch water 

dispensing spout.

- Avoid taking ice with cup filled with beverage, coffee etc.

- Cleaning up ice dispensing hole once a week is recommended. If foreign 

substance splashes onto ice dispensing hole, wipe it off right away.

- Separate cap from ice dispensing deco and clean up once a week.

<Do not install the unit in places below>
- A place exposed to direct sunlight.
- Nearby toilet.
- In front of cooling-heating device.

Self 

maintenance

Checkup

Maintenance

- Clean up water dispensing spout, ice dispensing spout and water gutter on

regular basis.

- Do not throw away any liquid except water.

- If there is the water, throw it away and clean up once a week.

Filter

replacement

Unit with ACS

Unit without

ACS

- 5 minutes of flushing is necessary. If not, carbon power can be found in water tank.

- Do not allow external shock to the filter.

Prevention of

scale buildup

- The unit is designed to empty water every 4 days to prevent scale.

- In case the unit is not used for long of period time more than 4 days, empty

water in the tank completely to let new water come in and empty water
again to take fresh water.

- Empty water tank every month and clean up with soft cloth or dry cleaner.
- Regular cleaning is necessary to prevent scale buildup.

Summary of Contents for CHP-5321D

Page 1: ...Rev No 00 2F KOMOS B D 10 DODANG DONG WONMI GU BUCHEON SI GYEONGGI DO KOREA P O BOX 420 800 TEL 82 32 672 7431 FAX 82 32 671 6531 E MAIL goodeal chungho co kr http eng chungho co kr...

Page 2: ...iffer from the picture Unit appearance specification etc are subject to change without prior notice if necessary for improving unit performance The rated voltage of this unit is AC 230V 50Hz only http...

Page 3: ...ughly and keep it for your future reference Greetings Table of Contents 1 Unit features 3 4 2 Safety precautions 5 7 3 Installation cautions 8 4 Installation method 9 5 Usage 10 16 5 1 Display and fun...

Page 4: ...duces only pure ice by freezing point depression method which supplies purified water to ice making unit This method allows the pure water to freeze at 32 F 0 C while non pure water freeze at below th...

Page 5: ...prevent any damage from water leak Noise Prevention This reduces system operating noise by applying a dual noise prevention material utilizing a shock mitigation structure found at ice storage house...

Page 6: ...or a place exposed to rain or snow An electric shock or fire may occur Do not put candles lit cigarettes etc on the unit and do not install the unit near a heating appliance There is a danger of a fir...

Page 7: ...ith the possibility for serious injury or death Danger Symptoms under normal operations 1 During use of the unit a murmuring water flow sound a clattering ice dropping sound etc may occur during cold...

Page 8: ...tion After transporting the unit do not supply the power for at least 30 minutes to stabilize the unit Do not operate the unit on sloping surface This can cause a malfunction and trouble Do not tilt t...

Page 9: ...that brine water may not splash around area Brine water can easily be used for other purposes such as bathroom cleaning house cleaning laundering washing etc Never use the drainage water for drinking...

Page 10: ...0 minutes in order to stabilize the cooling system and safe use of unit Check if water is supplied into the unit properly and there are any leakages on every connection Check every connection part for...

Page 11: ...cup after selecting the desired water selection among ambient cold or hot HOT TANK HEATING OFF INSTANT HEATING SELECTION SWITCH ON OFF ICE MAKING SWITCH ON OFF Press the switch up and middle and down...

Page 12: ...5 2 Function setting and releasing Constant water function setting Pressing COLD AMBI HOT SELECTION BUTTON for 2 seconds to take ambient or cold water constantly Setting sound Dingdong Constant ambi e...

Page 13: ...Press COLD AMBI HOT SELECTION BUTTON for 10 seconds to release beep function WATER FULL ICE FULL HOT ICE LED blinks 5 times Releasing sound Ding Ding 10 seconds 10 seconds Constant water function rel...

Page 14: ...is served If ambient water is selected and it is not used for 10 seconds the system will automatically switch into cold water dispensing mode which is most frequented Default function There is no sep...

Page 15: ...releasing Press heating selection switch attached on the rear COLD AMBI HOT LED is changed in accordance with instant heating process as below Yellow Orange Red When instant heaing function is comple...

Page 16: ...very 4 days when frequency of use is low ACS cleaning function which has UV sterilizer as option provides users with always clean and safe water as any chemical and electrolysis equipment is not used...

Page 17: ...Ice forming and Ice harvesting action Ice forming action Spray cold water to the evaporator for given time Ice harvesting action Supply heat to the evaporator to remove ice from the evaporator When t...

Page 18: ...And coffee and beverage etc can make dispensing hole contaminated When ice dispensing hole is splashed with foreign substance such as coffee beverage etc clean up immediately Cleaning is recommended...

Page 19: ...d pull it out to the bottom Water dispensing spout Turn faucet deco to the left to disconnect it from the body Separate cap from ice dispensing deco and clean them Put the cap back into ice dispensing...

Page 20: ...by pressing ICE DISPENSING BUTTON Turn the drain switch ON after lifting the filter Cold water and ambient water are automatically drained for 11 minutes Detach the ambient water tank cover after loos...

Page 21: ...water completely and use it Wash your hands first and put on sanitary gloves Clean up the tank with soft cloth or dry cleaner Do not use chemicals or detergent Discard used cleaner sanitary gloves et...

Page 22: ...nstall the unit in places below A place exposed to direct sunlight Nearby toilet In front of cooling heating device Self maintenance Checkup Maintenance Clean up water dispensing spout ice dispensing...

Page 23: ...ough brine tube T Post carbon filter It removes dissolved gases and odors to improve water taste UV sterilizer It sterilizes the bacteria which may exist in source water by UV 9 1 Filter functions 9 2...

Page 24: ...water Check for water leakage If it is found turn off the unit and shut down source water valve 5 minutes of flushing is necessary before filter replacement Lift the filter and turn to the left and p...

Page 25: ...r Ambient water Hot water Ice Room temperature Ice making cycle Dailyicemakingcapacity Daily maximum ice making quantity Ice weight IGUASSU TINY 900 Refer to the front page 0 36 Gal 1 4 0 63 Gal 2 4 0...

Page 26: ...valve 4 5 6 Fitting Booster pump 5 years 3 years 5 years OLC Replacement cycle 3 years 3 years 5 years 3 years This is not warranty period This ideal replacement cycle is to make sure that product wor...

Page 27: ...n you still have problem as the power plug is inserted properly Is ice making switch is ON Ice is not served Put ice making switch ON Is tap water being supplied Wait until the tap water works Unplug...

Page 28: ...27 15 MEMO...

Reviews: