CHUBU COPORATION NJG-C Operation Manual Download Page 4

WARNING 

Danger

 

 

If    you smell gas, immediately stop operating the roaster, turn off the gas valve,   
open windows and doors to release the gas.    Contact the local gas supplier or 
fire department from a neighbors phone.    Never light a fire, turn on or off the light 
switches,  plug  or  unplug  any  electric  appliances  (ex.  exhaust  fan),  or  use  the 
telephone.      The Leaking gas can catch fire or cause an explosion 

     

No 

Fire

 

 

 
       

WARNING 

 
Use only the type of gas specified on the nameplate.    Improper gas source will cause   
fire, burns, or carbon monoxide poisoning or mechanical troubles.    If the gas source 
is not clear, contact the distributor of the roaster or the gas supplier. 

             

Out 

of 

Order

 

 

   

In case of relocation, check whether the type of supplied gas corresponds to   
the gas source named in the plate on the roaster. 
Improper  gas  source  will  cause  the  fire,  burn,  or  carbon  monoxide  poisoning  by 
abnormal  burning,  mechanical  troubles.  If  the  gas  source  is  not  clear,  contact  the 
distributor of the roaster or the gas supplier. 

Check  Gas  Source 

                             

 
Be sure to keep the roasters’ area free and clear from combustible materials. 
Combustible materials may cause a fire.     

                                 

Forbiddance 

 

 

Summary of Contents for NJG-C

Page 1: ...his manual for your immediate and future references Warning Check your local gas supplier for the proper instructions to follow in the event the user smells gas These instructions shall be posted in a...

Page 2: ...n operating instructions thoroughly before installing or servicing this equipment The following cautions indicate important safety subjects please follow these directions to prevent injury or property...

Page 3: ...damage Samples of sign Caution Electric Shock Indicates cautions including warnings Contents of the caution are shown in or around with pictures or words The sign in the left shows Caution Electric S...

Page 4: ...per gas source will cause fire burns or carbon monoxide poisoning or mechanical troubles If the gas source is not clear contact the distributor of the roaster or the gas supplier Out of Order In case...

Page 5: ...l examination the ventilating system during normal maintenance and clearing Warning For safety reason before operation check the clearance to combustible and non combustible construction such as floor...

Page 6: ...use overheating Forbidden Never disassemble or remodel the roaster Remodeling or disassembling may cause abnormal operation or troubles Contact your local service representative or the factory if you...

Page 7: ...te combustion or mechanical troubles No Installment Never use the roaster for any purpose other than the original usage specified by the manufactures Improper usage will may cause injury or property d...

Page 8: ...The roasting plate grilling mesh and roaster body are hot when in operation or just after using the roaster never touch them except the control part Touching the heated parts may cause burns Caution...

Page 9: ...on or damage Pull the Plug Out MAIN PARTS Roasting Plate Top Ring Burner Set Water Tank F V Damper under the Outer Case Grey color one Louver small Filter Outer Case Louver Large Charcoal Tray Charcoa...

Page 10: ...er setting a Burner Set to a Water Tank beforehand can be easily done Check whether a projection at leg of the burner is set into a hole on the water tank and the burner set should be set correctly an...

Page 11: ...NG POT Note 3 When putting water pay attention not to splash water onto the burner and or burner head Splashed or wet burner burner head will cause to ignition failure Burner Set Watering Pot Flame Ro...

Page 12: ...d Flame Adjustment Warning Operate the exhaust fan before igniting Without ventilation the roaster will burn incompletely and cause carbon monoxide poisoning injury or fire If the table cover table li...

Page 13: ...losed Position wait 15 seconds and try to ignite again Work of the re ignition within 15 seconds can not be done due to a mechanism of the safety device s working 3 After igniting the gas turn ON the...

Page 14: ...stment of Blowing Power Heat Power of Charcoal For adjusting blowing power turn the Blower Fan Control Knob For the High power turn the knob clockwise and for the Low power turn the knob counter clock...

Page 15: ...burns Do not shut off ventilation and exhaust fans until the charcoal has been removed or completely extinguished EXTINGUISHING after operation 1 Turn OFF the blower fan switch Check the gas control...

Page 16: ...Ring Charcoal Tray Charcoal Pot and Water Tank Wash the top ring charcoal tray charcoal pot and water tank with neutral detergent each time it becomes dirty every day Use caution when handling these...

Page 17: ...completely c For Flame Rod Please clean regularly In case the flame rod is immersed or washed in water dry it completely Stuck oil dirt or wet on around the area will cause error temperature failure t...

Page 18: ...FAILURE SAFETY DEVICE Therefore always keep the area around the detector clean with wiping regularly The electrode spring is transformed easily and handle it carefully 7 F V Damper Fire Volume Damper...

Page 19: ...Gas Burner Electrical 220V 1Ph 50 60Hz Electric Consumption 300 W Water Tank Capacity 2 500 cc Required Exhaust Air Volume 300 m3 h Required Fresh Air Supply Volume 300 m3 h Cooing Load 6 63 kW Gas C...

Page 20: ...TADA KUWANA MIE 511 0943 JAPAN PHONE 81 594 31 2221 FAX 81 594 31 How to change Thermal Fuse This photograph shows a normal state This photograph shows the state that a thermal fuse blows out Thermal...

Page 21: ...21 Pin Lock portion Lever Turn the lever counterclockwise Hang the Lock portion on a pin of a fuse holder...

Reviews: