Model Volts 

Phase

kW

Heating 

Element

NWHO-1830R15

240

L

L

30

155-013185-331

NWHO(F)-1830R15

240

L

L

30

155-045301-013

NWHO-1830R15

480

L

L

30

155-013185-332

NWHO(F)-1830R15

480

L

L

30

155-045301-014

NWHO-1840R15

240

L

L

40

155-013185-004

NWHO(F)-1840R15

240

L

L

40

155-045301-016

NWHO-1840R15

480

L

L

40

155-013185-005

NWHO(F)-1840R15

480

L

L

40

155-045301-017

NWHO-1850R15

240

L

L

50

155-013185-007

NWHO(F)-1850R15

240

L

L

50

155-045301-019

NWHO-1850R15

480

L

L

50

155-013185-008

NWHO(F)-1850R15

480

L

L

50

155-045301-020

NWHO-1860R15

240

L

L

60

155-013185-010

NWHO(F)-1860R15

240

L

L

60

155-045301-022

NWHO-1860R15

480

L

L

60

155-013185-011

NWHO(F)-1860R15

480

L

L

60

155-045301-023

NWHO-1870R15

240

L

L

70

155-013185-013

NWHO(F)-1870R15

240

L

L

70

155-045301-025

NWHO-1870R15

480

L

L

70

155-013185-014

NWHO(F)-1870R15

480

L

L

70

155-045301-026

NWHO-1880R15

240

L

L

80

155-013185-016

NWHO(F)-1880R15

240

L

L

80

155-045301-028

NWHO-1880R15

480

L

L

80

155-013185-017

NWHO(F)-1880R15

480

L

L

80

155-045301-029

RENEWAL PARTS IDENTIFICATION

Note:

The “F” in NWHO(F) means forced circulation (ie: equipped with baffles.) When replacing the heating element, care must be taken that the baffles line up properly with the inlet and outlet pipes. The top of the

flange of replacement heating elements for forced circulation heaters is stamped near one edge with the letter “P”. The sub-assembly is positioned correctly when the “P” on the flange is in line with the inlet and out-
let pipe. Incorrect placement will result in hindered circulation and possible failure of the element.

Note:

When ordering parts for Model Numbers suffixed by “XX” or any other letter or letters not specifically identified on this instruction sheet, order Renewal Parts on special order basis, giving name of part, part

number and description.

MAINTENANCE

ELECTRIC SHOCK HAZARD. Disconnect all power
before installing or servicing heater. Failure to do so
could result in personal injury or property damage.
Heater must be installed by a qualified person in
accordance with the National Electrical Code, NFPA
70.

1.

Remove heating element assembly periodically to check heater
sheath for scaling, corrosion or excessive oxidation. Correct oper-
ating conditions to minimize sheath deterioration.

2.

Periodically check temperature control and limit control operation
to insure accurate and safe process operation.

3.

Check all electrical connections periodically and retighten connec-
tions which may have loosened in service. Replace wire and wire
terminals which show signs of oxidation which would interfere
with establishment of reliable electrical connections.

Regular Oil Heaters

Model Volts 

Phase

kW

Heating 

Element

NWHO-1820F15

240

L

L

20

155-013185-019

NWHO(F)-1820F15

240

L

L

20

155-045301-001

NWHO-1820F15

480

L

L

20

155-013185-020

NWHO(F)-1820F15

480

L

L

20

155-045301-002

NWHO-1825F15

240

L

L

25

155-013185-022

NWHO(F)-1825F15

240

L

L

25

155-045301-004

NWHO-1825F15

480

L

L

25

155-013185-023

NWHO(F)-1825F15

480

L

L

25

155-045301-005

NWHO-1830F15

240

L

L

30

155-013185-025

NWHO(F)-1830F15

240

L

L

30

155-045301-007

NWHO-1830F15

480

L

L

30

155-013185-026

NWHO(F)-1830F15

480

L

L

30

155-045301-008

NWHO-1835F15

240

L

L

35

155-013185-028

NWHO(F)-1835F15

240

L

L

35

155-045301-010

NWHO-1835F15

480

L

L

35

155-013185-029

NWHO(F)-1835F15

480

L

L

35

155-045301-011

NWHO-1840F15

240

L

L

40

155-013185-031

NWHO(F)-1840F15

240

L

L

40

155-045301-031

NWHO-1840F15

480

L

L

40

155-013185-032

NWHO(F)-1840F15

480

L

L

40

155-045301-032

NWHO-1845F15

240

L

L

45

155-013185-034

NWHO(F)-1845F15

240

L

L

45

155-045301-034

NWHO-1845F15

480

L

L

45

155-013185-035

NWHO(F)-1845F15

480

L

L

45

155-045301-035

Fuel Oil Heaters

OPERATION

FIRE/EXPLOSION HAZARD.

Do not exceed the

Pressure-Temperature rating of the flange as listed in
ANSI B16.5.

IMPORTANT: It is the responsibility of the purchas-
er of the heater to make the ultimate choice of
sheath material based upon his knowledge of the
chemical composition of the corrosive solution,
character of the materials entering the solution,
and controls which he maintains on the process.

Sheath corrosion can result in a ground fault
which, depending upon the solution being heated,
can cause an explosion or fire.

1.

Do not heat solutions that are corrosive to the heating element
sheath or the heating chamber.

2.

Terminal ends of heater must be protected from drippings, con-
densation, spray or direct spill-over of material. Their presence at
the terminals may damage heater electrical insulation. Liquid-tight
terminal enclosures are available to protect heater. Check with
local sales office.

3.

If foreign material is carried by the liquid flow, install suitable fil-
ters in the inlet pipe line to the heater.

4.

Do not allow heater to operate when liquid flow is interrupted.

Reviews: