background image

T A   -   Q0 -   E F

Litho in U.S.A.

2150 N. RULON WHITE BLVD., OGDEN, UT 84404

Phone: 1-800-368-2493         www.chromalox.com

Model Number

Used On

FT

RFT

Std. Teflon

®

Heaters

FLT

RFLT

L- Shaped Teflon

®

Heaters

F Amp Capacity - 25 Amps; RF Amp Capacity - 5 Amps; 
Blank (low) Temp = 180˚F

Low temp. most common for this style heater.

RF sensors require additional Control Components which include a Relay,
Audible Alarm, and Manual Reset Pushbutton.

Specify 120 or 240V when ordering.

For process temperatures above 180˚F, consult factory.

Thermal Fuse Replacement Protection Devices

THERMAL FUSE INSTALLATION/REPLACEMENT (con’t.)

Limited Warranty:

Please refer to the Chromalox limited warranty applicable to this product at

http://www.chromalox.com/customer-service/policies/termsofsale.aspx.

Summary of Contents for PD444-2

Page 1: ...nowledge of the chemical composition of the corrosive solu tion character of the materials entering the solu tion and controls which he maintains on the process Chromalox cannot warrant any electric immersion heater against failure by sheath corrosion if such failure is the result of operating conditions beyond our control 1 Heater Construction Characteristics A High quality resistance wire held i...

Page 2: ...ed in a threaded hole first thread the body into the hole then follow steps 1 thru 3 6 If the fitting is used thru an opening use the locknut and plastic washer to fasten it Opening for 1 2 NPT thread is 7 8 Ground L2 Thermostat Thermal Fuses Black Black Green Fused Disconnect Customer Supplied L3 L1 Heater Black Figure 4 Ground L2 L1 Thermostat Thermal Fuse Heater Black Black Green Fused Disconne...

Page 3: ...ones Single Use Fuse F Sensor consists of a one time thermal fuse sensor which is standard on all GTF over the side heaters The F thermal fuse is wired in series with the controller To operate properly the fuse must be fully seated to the bottom of the thermowell tube When the fuse blows shut off the main power to the heater remove the spent fuse and install the new fuse Refill the tank to the pro...

Page 4: ... for this style heater RF sensors require additional Control Components which include a Relay Audible Alarm and Manual Reset Pushbutton Specify 120 or 240V when ordering For process temperatures above 180 F consult factory Thermal Fuse Replacement Protection Devices THERMAL FUSE INSTALLATION REPLACEMENT con t Limited Warranty Please refer to the Chromalox limited warranty applicable to this produc...

Reviews: