6
HSK-PC End Termination
For use with SRF Heating Cables
1. Score the outer jacket 2” from the end of the cable.
Remove the jacket to expose the braid.
When removing the outer jacket, be careful not
to damage the braid or the base cable insulation.
3. Slide the heat shrink cap over the end of the cable.
Apply heat evenly until it shrinks around the cable.
2. Push the braid back, and cut off the end 3/4” of the
base cable.
ELECTRIC SHOCK HAZARD. To prevent short cir-
cuits, do not connect the buss wires together.
Keep braid out of heat shrink cap.
4. Pull the pushed-back braid over the sealed end cap
and twist the braid end together.
2”
Score the jacket and remove to
expose braid.
3/4”
• Cut off 3/4” of
base cable
Pull braid over cap and twist together.
5. Slide the 4” woven braid sleeving over the end of
the cable, allowing at least 1/2” to extend past the
end of the cable.
• 4” woven braid sleeving.
• Allow 1/2” to extend past cable end.
• Push braid back
Heat Shrink Cap