WIRING DIAGRAMS

Element

Heater No Controls – 1-Ph Parallel

Return Wire

Unit

Control

L1

L2

L1

L2

Element

Heater No Controls – 3-Ph Delta

Unit

Control

L1

L2

L3

L2

L1

L3

Return Wires

Return Wire

Element

Heater 2 Pole Stat – 1-Ph Parallel

Unit

Control

Stat

L1

L2

L1

L2

Element

Return Wires

Unit

Control

Stat

Heater 3 Pole Stat – 3-Ph Parallel

L1
L2
L3

L1 L2 L3

Element

Heater LYD Relay – 1-Ph Parallel

Return Wire

Unit

Control

L1

L2

2

T2

T1

Element

Return Wire

Unit

Control

Heater LVC Relay – 1-Ph Parallel

L2

L1

T0

T1

2

Element

Return Wires

Unit

Control

Heater 3 Pole Contactor – 3-Ph Delta

Contactor

T0

T1

L1
L2
L3

24V

Element

Return Wires

Unit

Control

Contactor

Heater 3 Pole Contactor/TX – 3-Ph Delta

T0

T1

L1
L2
L3

24V

Limit

ed

 Wa

rr

anty:

Please refer to the Chromalox limited warranty applicable to this product at

http://www.chromalox.com/customer-service/policies/termsofsale.aspx.

Summary of Contents for CAF-20215

Page 1: ... 3 3 000 7 2 10 236 48 3 53 CAF 20430 277 1 3 000 10 8 10 236 48 3 53 CAF 20430 480 1 3 000 6 3 10 236 48 3 53 CAF 20430 480 3 3 000 3 6 10 236 48 3 53 CAF 20440 208 1 4 000 19 2 13 648 48 3 53 CAF 20440 208 3 4 000 11 1 13 648 48 3 53 CAF 20440 240 1 4 000 16 7 13 648 48 3 53 CAF 20440 240 3 4 000 9 6 13 648 48 3 53 CAF 20440 277 1 4 000 14 4 13 648 48 3 53 CAF 20440 480 1 4 000 8 3 13 648 48 3 5...

Page 2: ...uts from the terminal box area 3 Determine the correct mounting height and scribe or snap a level line on the wall to maintain each heater back plate in a horizontal alignment when mounting 4 Mount the back plate to the wall using suitable fasteners pro vided by customer using the scribed line on the wall to keep the heater level TIP Should the wall surface be uneven secure the heater back panel t...

Page 3: ...d on page 4 3 Wrap the supply ground wire to the green painted ground screw and tighten Note When heaters are mounted end to end remove the fin ishing end plate install a chase nipple and locknut in the ter minal box to insure grounding continuity and to protect the wiring Figure 4 Where heaters are spaced apart remove the finishing plate and use rigid conduit provided by customer for through wiri...

Page 4: ... Stat Heater 3 Pole Stat 3 Ph Parallel L1 L2 L3 L1 L2 L3 Element Heater LYD Relay 1 Ph Parallel Return Wire Unit Control L1 L2 2 T2 T1 Element Return Wire Unit Control Heater LVC Relay 1 Ph Parallel L2 L1 T0 T1 2 Element Return Wires Unit Control Heater 3 Pole Contactor 3 Ph Delta Contactor T0 T1 L1 L2 L3 24V Element Return Wires Unit Control Contactor Heater 3 Pole Contactor TX 3 Ph Delta T0 T1 L...

Reviews: