engine to create the desired effect. Scroll to Look Store and press Enter, scroll to 
desired Look and press Enter. Press Enter again for 2 seconds to save Look. 
 

Advanced, standalone. Set the PSU-30 to Control Mode 1.

 

Scroll to Look Store and press Enter, scroll to desired Look and press Enter to access 
the memory data. The data is presented as two numbers separated by a letter “c”. 
The number to the left of the c is the channel number and to the right is the channel 
level. Scrolling the wheel will select the channel number. To edit the channel level, 
press Enter to toggle to the alternate number and use the scroll wheel to adjust the 

level (shown as 0-255). Press Enter to toggle back to the channel number. When the 
desired effect is created press Enter for 2 seconds to save Look.

 

  Time Triggers 

 

The PSU-30 has real time triggering of the internal Looks. Press Enter and scroll to 
desired Time Trigger and press Enter. Press Enter to toggle between Day, Hour (24), 

Minutes and Look to be triggered, adjusting the setting with the scroll wheel as 
desired. Press Enter for 2 seconds to save settings.  By default Time Triggers will 
occur on all 7 days unless specified. The triggers will only be activated when the 
feature “When DMX is Lost” is set to Trig. 

  Set Day and Time 

 

Press Enter. Press Enter to toggle between Day, Hour (24) and Minutes, adjusting the 
setting with the scroll wheel as desired. When the Day and Time is set correctly 
press Enter for 2 seconds to save settings. 

  Display Backlight (Displ. Backlight) 

 

The LCD backlight can be set to go off after 5 seconds of no activity. Press Enter, 
scroll wheel to On (permanently) or Off (after 5 seconds) and press Enter for 2 
seconds to save setting. 

  Reset to Default 

 

Press Enter for 2 seconds to reset all menu items to factory defaults. Factory defaults 

are: DMX address = 001, Control Mode = 1 (367 channels HSI+FX), DMX Lost = 
Hold, Looks = default, Time Triggers deleted, Display = On. Sync FX = Master. 

  Sync Mode 

 

In normal operation internally generated FX should stay synchronised between PSU-
30’s for approx 30 minutes. If better synchronisation is required a timing signal can 

be run via a RJ45 patch (not crossover) cable between PSU-30’s. In order for this to 
work correctly one PSU-30 must be designated as the Master and all other must be 
set to Slave. 

 

 

 

Press Enter and use the scroll wheel to select Master or Slave. Press Enter for 2 

seconds to save setting. 

 

Summary of Contents for Color Block PSU30

Page 1: ...Chroma Q Color Block PSU30 User Manual Version 1 2 December 2006 PN 602 0503...

Page 2: ...e alteration to devices and their functionality without notice due to our on going research and development The Color Block PSU30 has been designed specifically for the professional entertainment ligh...

Page 3: ...t Overview 3 2 Operation 3 2 1 Cabling 3 2 2 Control 5 a Control menu 5 b DMX personality mode 1 3 7 c DMX personality mode 4 6 8 d DMX personality mode 7 9 9 2 3 Technical Information 10 a Specificat...

Page 4: ...comprising of 3 LEDs 2 Operation 2 1 Cabling 2 2 Control a Control menu b DMX personality mode 1 3 c DMX personality mode 4 6 d DMX personality mode 7 9 2 3 Technical information a Specifications b M...

Page 5: ...r levels of leakage current of the PSU 30 it is important that the XLR4 cables used are manufactured only to the specification detailed above It is also important that the cables are not coupled or un...

Page 6: ...or details Press Enter turn wheel to select control mode press Enter for 2 seconds to save Mode 1 367ch Individually grouped 120 x HSI FX Mode 2 360ch Individually grouped 120 x HSI Mode 3 360ch Indiv...

Page 7: ...seconds to save settings By default Time Triggers will occur on all 7 days unless specified The triggers will only be activated when the feature When DMX is Lost is set to Trig Set Day and Time Press...

Page 8: ...of smoothness of colour scrolling Smoothest is at 0 Most coarse is at 250 Rate will vary with scrolling speed 255 will override effects and switch to RGB Saturation for group 2 Green for group 2 Chann...

Page 9: ...p 2 Red for group 2 Channel 5 Intensity Effects 0 Static 1 63 Fade on fade off Variable range 63 the fastest 64 127 Fade on snap off Variable range 127 the fastest 128 191 Snap on fade off Variable ra...

Page 10: ...ty for group 1 Blue for group 1 Channel 4 Colour Step 0 255 Variable control of smoothness of colour scrolling Smoothest is at 0 Most coarse is at 250 Rate will vary with scrolling speed 255 will over...

Page 11: ...SU 30 will require little maintenance However as the unit is likely to be used in a stage environment we recommend periodical internal inspection and cleaning of any resulting dust and cracked oil res...

Page 12: ...r Block DB4 fixtures Pin 1 0VDC pin 2 control minus pin 3 control plus pin 4 48VDC The chassis should be ground bonded Note Due to the higher levels of leakage current of the PSU 30 it is important th...