![Chroma Color Block PSU30 User Manual Download Page 7](http://html1.mh-extra.com/html/chroma/color-block-psu30/color-block-psu30_user-manual_2604539007.webp)
Color Block PSU-30 User Manual
6
V1.2 December 2006
engine to create the desired effect. Scroll to Look Store and press Enter, scroll to
desired Look and press Enter. Press Enter again for 2 seconds to save Look.
Advanced, standalone. Set the PSU-30 to Control Mode 1.
Scroll to Look Store and press Enter, scroll to desired Look and press Enter to access
the memory data. The data is presented as two numbers separated by a letter “c”.
The number to the left of the c is the channel number and to the right is the channel
level. Scrolling the wheel will select the channel number. To edit the channel level,
press Enter to toggle to the alternate number and use the scroll wheel to adjust the
level (shown as 0-255). Press Enter to toggle back to the channel number. When the
desired effect is created press Enter for 2 seconds to save Look.
Time Triggers
The PSU-30 has real time triggering of the internal Looks. Press Enter and scroll to
desired Time Trigger and press Enter. Press Enter to toggle between Day, Hour (24),
Minutes and Look to be triggered, adjusting the setting with the scroll wheel as
desired. Press Enter for 2 seconds to save settings. By default Time Triggers will
occur on all 7 days unless specified. The triggers will only be activated when the
feature “When DMX is Lost” is set to Trig.
Set Day and Time
Press Enter. Press Enter to toggle between Day, Hour (24) and Minutes, adjusting the
setting with the scroll wheel as desired. When the Day and Time is set correctly
press Enter for 2 seconds to save settings.
Display Backlight (Displ. Backlight)
The LCD backlight can be set to go off after 5 seconds of no activity. Press Enter,
scroll wheel to On (permanently) or Off (after 5 seconds) and press Enter for 2
seconds to save setting.
Reset to Default
Press Enter for 2 seconds to reset all menu items to factory defaults. Factory defaults
are: DMX address = 001, Control Mode = 1 (367 channels HSI+FX), DMX Lost =
Hold, Looks = default, Time Triggers deleted, Display = On. Sync FX = Master.
Sync Mode
In normal operation internally generated FX should stay synchronised between PSU-
30’s for approx 30 minutes. If better synchronisation is required a timing signal can
be run via a RJ45 patch (not crossover) cable between PSU-30’s. In order for this to
work correctly one PSU-30 must be designated as the Master and all other must be
set to Slave.
Press Enter and use the scroll wheel to select Master or Slave. Press Enter for 2
seconds to save setting.