Color Block PSU-30 User Manual
10
V1.2 December 2006
2.3
Technical information
a. Specifications
Product code:
CHCBPSU30 (max 30 DB4s)
Dimensions:
483mm × 368mm × 89mm
19" × 14.5" × 3.5"
Weight:
11.1kg / 24.5lbs
Working Voltage:
100-240VAC 50/60Hz auto-switching
Power consumption:
18A @120VAC; 9A @ 240VAC
Output connector in/out:
XLR4
Sync:
Ethercon RJ45 in and through
Power connector:
Trailing lead
Control:
ANSI E1.11 USITT DMX 512-A
Body color:
Black power coated paint
IP Rating:
IP20
Fuses:
Both live and neutral are fused
110V - 2 x 20A 1.25” ceramic
220V - 2 x 10A 1.25” ceramic
Cooling:
5 x rear mounted fans, ventilation required front and rear
Operating temperature:
0º C to + 40º C
Approvals:
EN55103-1, 55103-2, IEC60950
b. Maintenance
With care the Color Block PSU-30 will require little maintenance. However, as the unit is likely to
be used in a stage environment we recommend periodical internal inspection and cleaning of
any resulting dust and cracked oil residue. In addition the internal battery will need to be
replaced on a regular basis (see following section).
Do not spray liquids on the front or rear panel. If the front enclosure requires cleaning, wipe
with a mild detergent on a damp soft cloth.
c. Battery replacement
The CR20/32 Lithium battery should last approximately 5 years from the date the battery was
made – note that a 4 year life from date of product sale would not be unexpected when delivery
and manufacturing times are allowed for.
Caution:
Danger of explosion if battery is incorrectly replaced. Replace only with the same or
equivalent type recommended by the manufacturer. Dispose of used batteries according to the