FILTER CARE/REPLACEMENT PROCEDURE

The filter prevents dust from accumulating on the optical elements inside the projector. Should the 
filter become clogged with dust particles, the effectiveness of the cooling fans will be reduced and may 
result in internal heat buildup which will adversely affect the life of the projector. If the projector 

reaches a time set in the timer setting, a Filter replacement icon 

 appears on the screen and the 

WARNING FILTER indicator on the top panel lights up (refer to Figure 1). When you see this icon, 
replace the filter as soon as possible. If the filter is out of scroll and the projector reaches a time set in 

the timer setting, 

 appears on the screen indicating filter cartridge replacement is necessary.

When the filter scroll is counted down to 1, the Last scroll icon 

 appears on the screen, indicating 

there is one scroll left in the filter cartridge.
If the projector detects that the filter is clogged and no scroll is left in the filter cartridge, a Filter 

cartridge replacement icon 

 appears on the screen and the WARNING FILTER indicator on the top 

panel lights up (refer to Figure 1). When you see this icon, replace the filter cartridge and reset the 
Filter counter and the Scroll counter.
When the filter is being scrolled by the remote control or the Filter control function in the setting 

menu, a Filter replacement icon and “Please wait...” message 

 appear on the screen and the 

WARNING FILTER indicator blinks slow (approx. 2 seconds ON, 2 seconds OFF).
The WARNING FILTER indicator blinks fast when the projector detects an abnormal condition, the 
filter cartridge is not installed properly, or the filter scroll is not working properly.

 NOTICES

• The icons will not appear when the Display function is set to “Off”, or during “Freeze” .

• The filter cannot be rewound; it can be scrolled 9 times since the filter cartridge has 10 scrolls.

• The filter cartridge is disposable. Do not clean and reuse the filter cartridge; Do not expose the 
filter cartridge to water or liquid, or it may cause a malfunction.

• Replace the filter cartridge after all the scroll is used up. If you replace the filter cartridge when 
there are scrolls remaining in the filter cartridge, the filter counter and the scroll counter do not 
recognize the correct number of remaining scrolls and the reset function cannot work properly. It 
may cause a malfunction.

• The used part of the filter can be seen on the edge of the Filter cartridge after scrolling the filter, 
but there is no problem for the use of the projector.

• Do not use the filter cartridge with other projectors. The filter counter and the scroll counter do 
not recognize the correct number of remaining scrolls of the used filter cartridge and the reset 
function cannot work properly. It may cause a malfunction.

• Make sure that the projection lamps are turned off when you are replacing the filter cartridge. If 

you replace the filter cartridge when the projection lamps are turned on, the projector will be shut 
down automatically for safety purposes.

• Do not forget to reset the filter counter and the scroll counter after replacing the filter cartridge. 

If you do not reset the filter counter and the scroll counter, the projector cannot recognize the 
correct number of remaining scrolls and it may cause a malfunction.

• When the projector is in use for 3 minutes without a new filter cartridge replacement following 

display “Filter Cartridge Replament” icon, the projector is turned off automatically to prevent 
damage to the optical components.

Summary of Contents for LX900

Page 1: ...ting the lamp cover KITS REQUIRED 003 120394 01 Replacement Lamp Type No POA LMP104 003 002003 01 Replacement Air Filter INSTRUCTIONS DANGER Do not drop the lamp assembly or touch a glass bulb The glass can shatter and may cause injury DANGER Disconnect all power sources to the projector before opening lamp cover WARNING Allow a projector to cool for at least 45 minutes before you open Lamp Cover ...

Page 2: ... uses a high pressure lamp which must be handled carefully and properly Improper handling may result in accidents injury or create a fire hazard Lamp life will differ from lamp to lamp The environment in which the lamp is used is also a factor If the LAMP 1 REPLACE LAMP 2 REPLACE indicators light up replace the lamp with a new one IMMEDIATELY after the projector has cooled down There is a risk of ...

Page 3: ...replaced When the Lamp counter is reset the LAMP REPLACE indicator will turn off and the Lamp Replacement icon disappears 1 Press the MENU button to display the On Screen Menu Use the Point buttons to move the red frame pointer to the Setting Menu icon 2 Use the Point buttons to move the red frame pointer to Lamp counter and then press the SELECT button A dialog box appears Select a lamp and the L...

Page 4: ... installed properly or the filter scroll is not working properly NOTICES The icons will not appear when the Display function is set to Off or during Freeze The filter cannot be rewound it can be scrolled 9 times since the filter cartridge has 10 scrolls The filter cartridge is disposable Do not clean and reuse the filter cartridge Do not expose the filter cartridge to water or liquid or it may cau...

Page 5: ...ns to move the red frame pointer to Filter counter and then press the SELECT button A dialog box appears showing the Used Time option you can scroll to view the remaining Time options Use the buttons to select Used time 3 Used time shows the total accumulated time of the filter use a timer setting option and the Reset option Select Reset and the Filter counter Reset appears Select Yes to continue ...

Page 6: ...A dialog box appears showing the Used Time option and the Scrolls remaining option Use the buttons to select Scroll s remaining 3 Scroll s remaining shows the number of the remaining scrolls and the Reset option Select Reset and the Scroll counter Reset appears Select Yes to continue 4 Another confirmation dialog box appears select Yes to reset the Scroll counter Select Scrolls remaining to displa...

Reviews: