-33-
Mechanical Disassembly
Optical lamp
duct B
(T3x8)
Optical lamp
duct A
Wiring on optical lamp cover (Bottom side)
SW904
ID I/F 1 board
SW903
ID I/F 2 board
10 Ballast assy and Filter duct assy removal
1 Remove 3 screws-A (T4x10) and take the ballast assy off.
2 Remove the filter cover and filter cartridge.
3 Remove 4 screws-B (T4x10) and take the Filter duct assy off.
Ballast assy
Filter cover
Filter cartridge
Filter duct assy
A
A
A
B
B
B
B
Optical lamp
cover shield
Black tube
Transparent tube
DS+750 Service Manual
020-000211-01 Rev. 1 (06-2009)