Electromagnetic Compatibility 

Emitted Interference 

EN55032 Class A 

Immunity of supply line DC 

±2 kV according to IEC 61000-4-4; EFT 
± 0,5 kV according to IEC 61000-4-5; Surge asymmetrical 

Immunity of signal lines  

±1 kV according to IEC 61000-4-4; EFT 

ESD 

± 4 kV Contact discharge according to EN61000-4-2 
± 8 kV Air discharge according to EN 61000-4-2 

Immunity of conducted emission 

3 V 150 kHz 

 80 MHz, 80% AM nach IEC 61000-4-6 

Immunity of  high-frequency radi-
ation 

3 V/m 80 MHz 

 1 GHz, 80% AM nach IEC 61000-4-3 

3 V/m 1 GHz 

 6 GHz, 80% AM nach IEC 61000-4-3 

Table 19: Electromagnetic Compatibility 

  

9.4

 

Environmental Conditions 

Operating Temperature (Stand-
ard Conditions) 

0 ~ 50 °C 

Operating Temperature (Different 
Conditions) 

0 ~ 60 °C (see device-specific datasheet) 

Storage Temperature 

-10 ~ 70 °C 

Humidity 

5 ~ 80 % (non condensing) 

Protection Class (Standard Con-
ditions) 

IP20 

Transportation and Storage 

Suitable packing increases shock resistance 

max. Installation Altitude 

2000 m 

Cooling 

Natural Air Convection 

Table 20: Environmental Conditions 

  

Summary of Contents for PA10009320

Page 1: ...09 2021 www christ es com Instruction manual IndustrialsPC ...

Page 2: ...nditions 15 4 1 Temperature test 15 4 2 IP Protection Class 15 5 Assembly and Commissioning 16 5 1 Connection of the power supply 17 5 2 Earth Connection 17 5 3 Mounting Industrial PC 17 5 4 Dismounting Industrial PC 18 6 Accessories and Spare Parts 19 7 Software 20 7 1 BIOS Basic Settings 20 7 1 1 COM Port configuration 20 7 1 2 Set Boot Priority 21 7 2 BIOS Update 23 7 2 1 Preparation 23 7 2 2 P...

Page 3: ... 1 Cleaning 27 8 2 Maintenance 27 9 Technical Data 28 9 1 Mechanical Specifications 28 9 2 Electrical Specifications 28 9 2 1 Power Consumption 28 9 3 Electromagnetic Compatibility 29 9 4 Environmental Conditions 29 10 Standards and Approvals 30 10 1 CE Marking 30 10 2 RoHS 30 10 3 Electromagnetic Compatibility 30 10 4 Environmentally Appropriate Disposal 30 11 Technical Support 31 11 1 Device Sea...

Page 4: ...trol medical life support systems and weapons systems con trol Technical changes Christ Electronic Systems GmbH reserves the right to change the information designs and technical data contained in this documentation without prior notice Copyright No part of this documentation may be reproduced in any form or processed duplicated or distributed using electronic systems without the prior written con...

Page 5: ...s may result in death or serious injury WARNING Indicates a dangerous situation Failure to observe this warning may result in serious injury or major damage to property CAUTION Indicates a possible dangerous situation Failure to observe the advice can result in injuries or property damage NOTICE Indicates user tips and useful information Important information to avoid malfunctions ...

Page 6: ...over a long period of time The optional integrated UPS prevents data loss during power fluctuations If the power fails the devices are shut down properly The Industrial PCs can be loaded with either Windows or Linux before delivery and are then immedi ately ready for use Thanks to the compact housing design Christ Industrial Computers can also be optimally used in con fined spaces Despite their sm...

Page 7: ... RS 485 Bios setting RJ50 1 x Display Port 1 0 Table 2 System overview Argon Titanium CPU Intel Celeron 3965U 2 2 GHz Intel Core i3 7100U 2 4 GHz Intel Core i5 7300U 2 6 GHz Intel Core i7 7600U 2 8 GHz Graphic Intel HD Graphics 610 Intel HD Graphics 620 Memory 2 x DDR4 slot in summary max 32 GB BIOS AMI Optio 5 BIOS Interfaces 4 x USB 2 x USB 2 0 Port Type A 2 x USB 3 0 Port Type A 2 x 1 GBit Ethe...

Page 8: ...ousing Variant Industrial PC Illustration 1 Industrial PC 1 DIN Rail 35 mm x 7 5 mm DIN Rail 35 mm x 15 mm 2 Interface Area Table 4 Industrial PC Front Illustration 2 Dimensions Industrial PC Architecture A B C D Argon 180 130 33 90 Titanium 230 160 33 115 Table 5 Dimensions Industrial PC ...

Page 9: ...2 3 Add On UPS Uninterruptible Power Supply Energy Storage 400 Ws Charge Duration 90 in 45 seconds 100 in 80 seconds Configuration Shutdown Time Dimming Time Dimming Intensity The instruction for the UPS can be found in the FAQ section of the Christ website FAQ Questions and Answers ...

Page 10: ... 1 GND Ground 2 FE Functional Earth 3 24 VDC Supply Table 6 Pinout Supply Connector screwable USB Host 2 0 Type A PIN Function Description 1 VBUS USB VCC 2 D USB Data 3 D USB Data 4 GND USB Ground Table 7 Pinout USB 2 0 USB Host 3 0 Type A PIN Function Description 1 VBUS USB VCC 2 D USB Data 3 D USB Data 4 GND USB Ground 5 StdA_SSRX SuperSpeed transmitter differential pair 6 StdA_SSRX SuperSpeed t...

Page 11: ...Description 1 D1 Transmit Data 2 D1 Transmit Data 3 D2 Receive Data 4 D3 Bidirectional 5 D3 Bidirectional 6 D2 Receive Data 7 D4 Bidirectional 8 D4 Bidirectional Table 9 Pinout Ethernet WLAN Mating Connector SMA RP SMA Description Transmis sion Stand ard 802 11 ac a b g n 2 4 GHz 5 GHz Table 10 Pinout WLAN ...

Page 12: ...nsmitter Differential Pair DATA Data Differ ential Pair B 3 TX Transmit Data RX Receiver Dif ferential Pair n c not con nected 4 DTR Data Trans mit Ready RX Receiver Dif ferential Pair n c not con nected 5 GND Ground GND Ground GND Ground 6 DSR Data Set Ready n c not con nected n c not con nected 7 RTS Ready To Send n c not con nected n c not con nected 8 CTS Clear To Send n c not con nected n c n...

Page 13: ... Transmit Data RX Receiver Dif ferential Pair n c not con nected 5 RXD Receive Data TX Transmitter Differential Pair DATA Data Differ ential Pair B 6 DCD Data Carrier Detect TX Transmitter Differential Pair DATA Data Differ ential Pair A 7 DTR Data Termi nal Ready RX Receiver Dif ferential Pair n c not con nected 8 CTS Clear To Send n c not con nected n c not con nected 9 RTS Request To Send n c n...

Page 14: ...DP data3 13 CONFIG1 CAD Cable adapter recognized 14 CONFIG2 Ground Pull Down 15 AUX_CH Additional device 16 GND Ground 17 AUX_CH Additional device 18 HPD Hot Plug recognized 19 GND Ground 20 DP_PWR 3 3V Power Supply DP Table 13 Pinout Display Port With the DP1 0 it is not possible to display an image on DVI HDMI devices An active adapter with properties of DP is required for this 1 Display Port 1 ...

Page 15: ...mperature and humidity were determined under worst case conditions The maximum workload of the system was achieved by the BurnInTest from PassMark Software Pty Ltd The test ran under 100 utilisation of CPU RAM 2D and 3D Graphic x86 only Brightness of the display 4 2 IP Protection Class The protection class only can be guaranteed under the following conditions The device is installed correctly All ...

Page 16: ...and do not open the covers WARNING Dropping a device Injuries and bruises to the legs and or feet Wear safety shoes Note for the installation site This device is not designed for outdoor use Make sure that the ambient temperature and humidity are within the ranges which are specified under Environmental Conditions Do not install the device directly in the sunlight Make sure that the device is inst...

Page 17: ...ith a screwdriver and a maximum torque of 0 3 Nm The rear view 4 of the connector is shown for clarification Illustration 3 Connection of the power supply 5 2 Earth Connection NOTICE Earthing not connected Not guaranteed functionality of the device All earth connections must be connected to an earth point 5 3 Mounting Industrial PC Step 1 Hook the Industrial PC onto the fastening rail at an angle ...

Page 18: ...Dismounting Industrial PC Step 1 Pull down on the pull cord to release the Indus trial PC Step 2 Tilt the Industiral PC forward with the pull cord pulled at the bottom and unhook it at the top Illustration 6 Dismounting Industrial PC Step 1 Illustration 7 Dismounting Industrial PC Step 2 ...

Page 19: ... Christ and are compatible with the products The following accessories are available Power supply Input Voltage 90 264 VAC Input Current max 1 A Input Frequency 47 63 Hz Consumption with unloaded out put max 0 075 W Output Voltage 24 VDC Output Current max 2 5 A Temperature Range Operation 0 70 C Humidity Operation 20 80 RH non condensing Table 14 Power supply ...

Page 20: ...pply Accessing the BIOS works by pressing the Del key several times while the device is booting The following tabs in the BIOS enable various settings Main Set date Advanced Make advanced BIOS settings like COM ACPI etc Chipset Enter host bridge parameters Security Set administrator password Boot Set Boot Option Save Exit Save the settings made and initiate a restart Also possible with the F4 key ...

Page 21: ...F81804 Super IO Configuration 3 Select Serial Port1 Configuration 4 Under F81846 SERIAL PORT1 MODE SELECT select the mode RS232 RS422 RS485 5 If RS422 or RS485 mode has been selected settings can be made for RS422 RS485 Termination or RTS Auto Flow Control 6 Save with keystroke F4 confirmation with Yes Illustration 9 BIOS COM Port Titanium 7 1 2 Set Boot Priority Set Boot Priority Argon Titanium I...

Page 22: ...Industrial PC Instruction Manual Document No PA10009320 22 33 Sep 2021 Revision 00 llustration 10 BIOS Boot Priority ...

Page 23: ...Boot Priority The EFI Update Script is automatically detected on the USB stick and starts the update process Further procedure Argon Confirm the question Enter q to quit any other key to continue with Enter Illustration 11 Argon BIOS Update Confirm the question Do you want to continue Y N or q to quit with y The update is executed The message FPT Operation Successful indicates successful completio...

Page 24: ...message FPT Operation Successful indicates successful completion Illustration 14 Titanium BIOS Update successful Disconnect the power supply Restore the power supply and enter the BIOS again do not reboot Press the F3 key to confirm the question Load Optimized Defaults with Yes Press the F4 key to save and exit ...

Page 25: ...Monitor Utility for IBASE and activate it by clicking on Enable Illustration 15 Task Manager enable OBS Client 4 Perform a restart of the device 7 3 2 Functions of the OBS Client To start the OBS client expand the taskbar and click on the key icon Illustration 16 Start OBS Client These functions are provided by the OBS Client System Information The System Information provides information about the...

Page 26: ... Hardware Monitor Settings Various settings can be made in the Settings area Illustration 19 OBS Client Settings 7 4 Redo Backup and Recovery The instructions for Christ Redo Backup and Recovery can be found in the FAQ section of the Christ website FAQ Questions and answers 7 5 Enhanced Write Filter EWF Instructions on how to set EWF and UWF filters can be found in the FAQ section of the Christ we...

Page 27: ...ng unintended functions Loss of control of the plant machine device The unit may only be cleaned when it is switched off or unplugged To clean the device use a soft cloth moistened with detergent solution The cleaning agent must not be applied directly to the device Under no circumstances may aggressive solvents chemicals or scouring agents be used 8 2 Maintenance It does not require any maintenan...

Page 28: ...onsumption see table Power Consumption Continuous Rated Current max 2 5A Inrush Current load independ ent max 70A for 80 µs Used power supply FSP060 DAAN3 External Power Supply SELV Earthing Functional Earthing Cable cross section has to be identical to the supply lines Battery Lifetime 4 years constantly turned off Table 17 Electrical Specifications 9 2 1 Power Consumption Architecture Power Cons...

Page 29: ...ted emission 3 V 150 kHz 80 MHz 80 AM nach IEC 61000 4 6 Immunity of high frequency radi ation 3 V m 80 MHz 1 GHz 80 AM nach IEC 61000 4 3 3 V m 1 GHz 6 GHz 80 AM nach IEC 61000 4 3 Table 19 Electromagnetic Compatibility 9 4 Environmental Conditions Operating Temperature Stand ard Conditions 0 50 C Operating Temperature Different Conditions 0 60 C see device specific datasheet Storage Temperature ...

Page 30: ... listed below EN 55032 2015 Class A Electromagnetic compatibility of multimedia equipment Emis sion Requirements EN 55035 2017 Electromagnetic compatibility of multimedia equipment Immun ity requirements 10 4 Environmentally Appropriate Disposal The device must not be disposed of with domestic waste The appliance complies with the requirement of the EU Directive WEEE 2012 19 EU which is symbolised...

Page 31: ...partment can start the repair quickly When the device arrives it goes through a defined process that clearly documents all processes and makes the respective status traceable As soon as your panel or IPC is registered in our system you will receive a confirmation of receipt so that you can also get a precise overview Technical Support can be contacted as follows Service Repair and Technical Suppor...

Page 32: ... PC Step 1 18 Illustration 7 Dismounting Industrial PC Step 2 18 Illustration 8 BIOS 20 Illustration 9 BIOS COM Port Titanium 21 llustration 10 BIOS Boot Priority 22 Illustration 11 Argon BIOS Update 23 Illustration 12 Argon BIOS Update successful 23 Illustration 13 Titanium BIOS Update 23 Illustration 14 Titanium BIOS Update successful 24 Illustration 15 Task Manager enable OBS Client 25 Illustra...

Page 33: ...nector screwable 10 Table 7 Pinout USB 2 0 10 Table 8 Pinout USB 3 0 10 Table 9 Pinout Ethernet 11 Table 10 Pinout WLAN 11 Table 11 Pinout COM Connector Titanium 12 Table 12 Pinout COM Connector Celeron N3350 Argon 13 Table 13 Pinout Display Port 14 Table 14 Power supply 19 Table 15 BIOS 20 Table 16 Mechanical Specifications 28 Table 17 Electrical Specifications 28 Table 18 Power Consumption 28 Ta...

Reviews: