Operation 

2.1

 

CLM1000-Home operational system 

 

 

The 

Wattmeter CLM1000 – Home

 is made for measuring 

the following electric parameters: 

 

instantaneous real power [W] 

 

active energy (consumption) [kWh] 

 

active energy / 24 hours [kWh] 

 

test time [hh:mm] 

 
Switch  between  the  different  modes  using  the  arrow 
keys.

 

2.2

 

Brief instruction 

 

Connecting: 

 

 
 
 
 
 
 

 

 

Unplug  the  load  (e.g.  household  appliance,  HIFI, 
PC…) and plug it in the adapter of the measuring 
device. Subsequently connect the adapter of the 
measuring device to the socket. 
 
Now the measuring device is interposed between 
load  and  socket,  so  it  can  measure  power  and 
current consumption.

 

Menu item 1(3) 

 
 
 
 
 
 

When  the  CLM1000  is  plugged  in  it  automatically 
switches on and displays the instantaneous power 
of the connected electric appliance. 

Press        to continue to

 menu item 2(3)

 

By  selecting  the  second  menu  item  the  current 
consumption 

of 

the 

connected 

electric 

appliance is displayed. 
e.g.:  the  refrigerator  has  consumed  0.15  killowatt 
hours in 5 hours. 
By pressing both arrow keys for approx. 2 seconds 
the measuring will be reset to zero. 

 

socket 

 

adapter wattmeter 

power plug 
load

 

 

RESET 

1(3) 

WATT 

35.9 

RESET 

2(3) 

kWh 

0.1500 

5:00 

menu item  

Summary of Contents for CLM1000 Home

Page 1: ...hrist elektronik de Copyright It is forbidden to reproduce or process using electronic systems copy or distribute any part of this document Translation into another language requires written authorisation This document is for the personal use of the owner of the device or Christ Elektronik GmbH personnel only Technical modifications Christ Elektronik GmbH reserves the right to modify the designati...

Page 2: ... 2 Operation 3 2 1 CLM1000 Home operational system 3 2 2 Brief instruction 3 2 3 Contrast setting 4 3 Error handling 5 4 Technical data 6 4 1 CLM1000 variant types and measurings 6 4 2 Display and operation 7 4 3 Measuring principle and accuracy 7 4 4 Voltage supply 7 4 5 Environment and dimensions 7 ...

Page 3: ...r on the back of the device shall not be opened Warranty voids if the device is opened DANGER Ensure that any repairs to the unit are carried out by qualified personnel Substantial risk for the user arises from improper repairs Liquids and dust shall not enter the device Don t expose the device to humidity or solar radiation for any length of time DANGER Connect the CLM1000 only to approved securi...

Page 4: ...ring device to the socket Now the measuring device is interposed between load and socket so it can measure power and current consumption Menu item 1 3 When the CLM1000 is plugged in it automatically switches on and displays the instantaneous power of the connected electric appliance Press to continue to menu item 2 3 By selecting the second menu item the current consumption of the connected electr...

Page 5: ...on At 17 Cent per kWh 4 25 kWh 0 17 0 72 Here too it is advisable to reset the wattmeter to zero through pressing both arrow keys for approx 2 seconds before starting the measuring All readings are saved even after unplugging the wattmeter or a mains failure They will be recalled by plugging in again 2 3 Contrast setting Increase contrast Press the OK button and the arrow up button simultaneously ...

Page 6: ...lug the CLM1000 and plug it again If the error continues to exist the CLM1000 can t be used Please send in ERROR2 Internal error 2 The CLM1000 shows the error and all readings are reset The CLM1000 starts a new measuring If this error keeps occurring during start up the CLM1000 has to be sent in for further inspection ERROR3 Amperage above the maximum allowable value more than 16 ampere Unplug wat...

Page 7: ...24 h consumption 24 h 0 0000 108 0000 kWh 0 0001 kWh Apparent energy 0 0000 99999 99 kVAh 0 0001 0 01 kVAh Reactive energy 0 0000 99999 99 kvarh 0 0001 0 01 kvarh Consumption costs 0 00 99999 99 0 01 Consumption costs 24 h 0 00 99999 99 0 01 Tariff 0 000 99 999 0 001 Testing time 00 00 9999 59 h 1 minute ON threshold measuring 0 0 100 0 0 1 Voltage 100 0 264 0 V 0 1 V Voltage min max 100 0 264 0 V...

Page 8: ...ance is set to ohm resistance EEPROM Memory All readings are saved even after unplugging Measuring error 0 3 3 digit from reading at power factor 0 3 4 4 Voltage supply Connection Socket at the adapter permanent load max 16 A Supply voltage 100 264 VAC 47 63 Hz Power consumption 4 VA 4 5 Environment and dimensions Dimensions ABS plastic casing approx 200 95 35 mm L W H Weight approx 490 g Connecti...

Reviews: