1.1

 

Maintenance 

 

 

INFORMATION! 

This device is made to DIN EN ISO 9001 standard and has left the 
factory  in  flawless  condition  regarding  technical  safety. 
 
To maintain this condition and ensure safe operation pay attention 
to  the  information  and  warnings  contained  in  this  instruction 
manual. 

1.2

 

Safety instructions 

 

DANGER! 

If  the  casing,  connection  cable  or  another  part  of  the  device  is 
damaged, it is to be unplugged and switched off immediately. 

 

 

DANGER!

 

Before opening the casing unplug connecting cable. 

The  screws  at  the  battery  cover  on  the  back  of  the  device  shall 
not be opened. 

 

 

Warranty voids if the device is opened. 

 

 

DANGER! 

Ensure  that  any  repairs  to  the  unit  are  carried  out  by  qualified 
personnel. Substantial risk for the user arises from improper repairs.

 

 

Liquids  and  dust  shall  not  enter  the  device.  Don’t  expose  the 
device to humidity or solar radiation for any length of time!

 

 

 

DANGER! 

Connect  the  CLM1000  only  to  approved  security  sockets  100-264 
VAC/47-63 Hz with protective earth conductor. 
Maximum  power  of  any  kind  of  load  shall  not  exceed  4424  Watt 
(max. 16A). 

 

 

CAUTION! 

If the device is diverted from its intended use or operated wrongly 
no liability can be assumed for possible harms. 

 

The  device  shall  not  be  handled  with  abrasive  and  sharp-edged 
objects.  
The device shall not be cleaned with solvent-containing or acidic 
substances. 

Summary of Contents for CLM1000 Home

Page 1: ...hrist elektronik de Copyright It is forbidden to reproduce or process using electronic systems copy or distribute any part of this document Translation into another language requires written authorisation This document is for the personal use of the owner of the device or Christ Elektronik GmbH personnel only Technical modifications Christ Elektronik GmbH reserves the right to modify the designati...

Page 2: ... 2 Operation 3 2 1 CLM1000 Home operational system 3 2 2 Brief instruction 3 2 3 Contrast setting 4 3 Error handling 5 4 Technical data 6 4 1 CLM1000 variant types and measurings 6 4 2 Display and operation 7 4 3 Measuring principle and accuracy 7 4 4 Voltage supply 7 4 5 Environment and dimensions 7 ...

Page 3: ...r on the back of the device shall not be opened Warranty voids if the device is opened DANGER Ensure that any repairs to the unit are carried out by qualified personnel Substantial risk for the user arises from improper repairs Liquids and dust shall not enter the device Don t expose the device to humidity or solar radiation for any length of time DANGER Connect the CLM1000 only to approved securi...

Page 4: ...ring device to the socket Now the measuring device is interposed between load and socket so it can measure power and current consumption Menu item 1 3 When the CLM1000 is plugged in it automatically switches on and displays the instantaneous power of the connected electric appliance Press to continue to menu item 2 3 By selecting the second menu item the current consumption of the connected electr...

Page 5: ...on At 17 Cent per kWh 4 25 kWh 0 17 0 72 Here too it is advisable to reset the wattmeter to zero through pressing both arrow keys for approx 2 seconds before starting the measuring All readings are saved even after unplugging the wattmeter or a mains failure They will be recalled by plugging in again 2 3 Contrast setting Increase contrast Press the OK button and the arrow up button simultaneously ...

Page 6: ...lug the CLM1000 and plug it again If the error continues to exist the CLM1000 can t be used Please send in ERROR2 Internal error 2 The CLM1000 shows the error and all readings are reset The CLM1000 starts a new measuring If this error keeps occurring during start up the CLM1000 has to be sent in for further inspection ERROR3 Amperage above the maximum allowable value more than 16 ampere Unplug wat...

Page 7: ...24 h consumption 24 h 0 0000 108 0000 kWh 0 0001 kWh Apparent energy 0 0000 99999 99 kVAh 0 0001 0 01 kVAh Reactive energy 0 0000 99999 99 kvarh 0 0001 0 01 kvarh Consumption costs 0 00 99999 99 0 01 Consumption costs 24 h 0 00 99999 99 0 01 Tariff 0 000 99 999 0 001 Testing time 00 00 9999 59 h 1 minute ON threshold measuring 0 0 100 0 0 1 Voltage 100 0 264 0 V 0 1 V Voltage min max 100 0 264 0 V...

Page 8: ...ance is set to ohm resistance EEPROM Memory All readings are saved even after unplugging Measuring error 0 3 3 digit from reading at power factor 0 3 4 4 Voltage supply Connection Socket at the adapter permanent load max 16 A Supply voltage 100 264 VAC 47 63 Hz Power consumption 4 VA 4 5 Environment and dimensions Dimensions ABS plastic casing approx 200 95 35 mm L W H Weight approx 490 g Connecti...