Touch-it CE
Operating Instructions
Christ Elektronik GmbH
14
/
37
www.christ-elektronik.de
Tel.: +49 8331 8371-0
Like the RAM file system, the Windows CE registry is only stored to RAM every setting you change
will be lost after a power cycle, but there is a small utility to save the registry persistently.
Click on the Update Tool icon
and then press the button
Save Registry to Flash
.
You will get a message informing you if the saving was successful
3.2.2
PC Connectivity over Ethernet
The installation effort to set up an Ethernet connection depends on your available network infra-
structure.
If you have a DHCP server then it's very easy, just go to
Start Menu->Settings->Network and Dial-
up Connections,
double click on the network adapter and select "
Obtain an IP address via
DHCP
", confirm with OK.
If you don't have a DHCP server you can specify a static IP address to the system in this menu.
INFORMATION!
Don’t forget to make a Save Registry so the IP settings are stored persistent-
ly (See chapter Software and Registry).
Now if you have some shared files in your network you can easily access them by typing:
"\\computer name\share name" in the address bar of an explorer window.
After logging in you should be able to access the files on the network share.