5.3 

Safety pointers 

 

 

DANGER! 

In the case of damage of the device, shut it down and disconnect it imme-
diately from the supply voltage. 

 

Disconnect every

 connection line and send it back to Christ-Elektronik 

GmbH. 

 

 

 

 
DANGER!

 

Avoid any penetration of liquid or dust. 
Do not expose the device to humidity for a long time! 

 

 

 

Intended Use

 

These products are not designed, developed and produced for use, which 
pose fatal risks and dangers that may cause death, injuries, serious physi-
cal impairments or other loss, if no exceptional security measures are en-
sured. Thus there are limitations for use in the monitoring of nuclear reac-
tions in nuclear power plants, flight control systems, air traffic control, in the 
control of mass transportation, medical life support systems and control of 
weapon systems.  
 

 

 

 

CAUTION! 

If the device is used for other purposes or incorrectly operated,  
Christ-Elektronik GmbH will not hold damages liable. 

 

 

Do not

 operate the touch-sensitive surface of the screen with any abrasive 

or sharp-edged objects. 

 

Protect the

 Touch-it Panel PC against caustic chemicals and long solar 

radiation. 

 

 

Summary of Contents for Touch-it CE

Page 1: ...t CE Operating Instructions Christ Elektronik GmbH 1 37 info christ elektronik de www christ elektronik de Tel 49 8331 8371 0 Touch it CE Low Power Panel PC Different Housings Sizes From 7 to 15 Ready For Use ...

Page 2: ...y in any form be reproduced copied or distributed by means of electronic systems without previous written permis sion by Christ Elektronik GmbH The translation into another language also requires a written permission This documentation may be exclusively en trusted to the owner of the installation or to the employees of Christ Elektronik GmbH Technical chang es Christ Elektronik GmbH reserves the ...

Page 3: ... 4 1 Flash Disk 19 3 4 2 MicroSD Card 19 3 4 3 USB HD 19 3 5 Registry 20 3 6 Windows CE 6 0 EC 7 Bootloader Image Update 21 3 6 1 Image Update via external memory USB SD 21 3 6 2 Image Update via terminal connection 22 3 7 Running Applications at Startup Autorun 23 3 8 Adding Files to Desktop or Start Menu AutoCopy 23 3 9 Touch it CE remote control 24 4 Interfaces 26 4 1 Power Supply Connector 26 ...

Page 4: ...Tel 49 8331 8371 0 1 General OVERVIEW Series Touch it CE Housing Open Frame Open Frame glass Front Panel Front Panel glass VESA VESA glass Touch Foil Touch analog resistive Projected Capacitive Touch Sizes Display 7 15 CPU NVIDIA Tegra 2 T20 Dual Core 1 0 GHz Cortex A9 NVIDIA Tegra 3 T30 Quad Core 1 4 GHz Cortex A9 ...

Page 5: ...RAM 512 MB DDR2 RAM optional Storage 512 MB NAND FLASH 1 GB NAND FLASH optional Operating System Windows Embedded Compact 7 Pro Linux optional SYSTEM CPU NVIDIA Tegra 3 T30 Quad Core 1 4 GHz Cortex A9 Graphic Integrated Ultra low power NVIDIA GeForce GPU Video Decoder H 264 WMV9 VC 1 MPEG 4 MPEG 2 H 263 DiVX XviD Memory 1 GB DDR3 RAM Storage 4 GB NAND FLASH MicroSD Operating System Windows Embedde...

Page 6: ...me naturally anodized Glass black frame Housing Stainless steel Stainless steel Cooling Passive Active Protection Class IP20 IP 65 front IP20 IP 65 front Operating Temperature 0 50 C 0 50 C VESA VESA glass Housing Front Glass black frame Housing Aluminium anodized silver chemically shined Aluminium anodized silver chemically shined Cooling Passive Passive Protection Class IP20 IP 65 front IP20 IP ...

Page 7: ...christ elektronik de Tel 49 8331 8371 0 2 Commissioning 2 1 Mounting 2 1 1 Touch it CE Open Frame The variant Touch it CE Open Frame is designed for customer specific mounting Each Open Frame Panel has its own cut out drawing For example For the appropriated drawing see the specific data sheet ...

Page 8: ...ned for front mounting Each Front Panel has its own cut out drawing For the appropriated drawing see the specific data sheet To clamp the Front Panel into the cut out you can use the attached fasting clamps Fasting Clamp CAUTION For the best installation result the use of all provided fasting clamps is highly recommended Depending on individual installation cir cumstances a new IP rating may be co...

Page 9: ...lektronik de www christ elektronik de Tel 49 8331 8371 0 2 1 3 Touch it CE VESA The variant Touch it CE VESA is designed for VESA MIS D 75 C mounts Some panels can also be mounted with VESA MIS D 100 C Suitable mounting variants are VESA Desk Stand Arm Mounting System VESA SA75 ...

Page 10: ...Ethernet optional Communication 1 x RS 232 1 x RS 232 or RS 485 1 x CAN optional 8 x I Os optional Mass Storage 1 x microSD up to 32GB Power Connector Phoenix Connector side Touch it CE completely Connector side Touch it CE standard Connector side Touch it CE CODESYS ready These are the standard interface configurations Others are possible For the correct interface configuration see the specific d...

Page 11: ...Cable Type A Type mini B between your PC USB port and the USB on the Touch it CE Be sure that only the mini USB port is connected and not the shared one If you use the Touch it CE Pico ITX glass be sure that the touchscreen is not connected to the inter nal USB port Now a connection should be established and a partnership between PC and CE Device will be created You can save the Registry now so th...

Page 12: ...rist elektronik de Also Windows Mobile Device Center can be used to install applications Most of the Windows CE applications you can find on the WEB have an installer that expects Windows Mobile Device Center to be present on your system and will use it to install the software on the CE Device If you want to try some third party software from the WEB be sure to download the ARM com piled Handheld ...

Page 13: ... that Windows CE offers Open the My Device folder upper left icon on the desktop This is the root folder of Windows CE In Windows CE there are no Drive letters like in other Windows Versions so everything in the file system can be found under the root folder Almost every subfolder in the root folder resides in RAM so if you copy change delete some thing there it will only have a temporary effect a...

Page 14: ... set up an Ethernet connection depends on your available network infra structure If you have a DHCP server then it s very easy just go to Start Menu Settings Network and Dial up Connections double click on the network adapter and select Obtain an IP address via DHCP confirm with OK If you don t have a DHCP server you can specify a static IP address to the system in this menu INFORMATION Don t forg...

Page 15: ...tion90DayTrialDEUX1435986 iso INFORMATION These two download are not provided on the www christ elektronik de homepage 1 Install Visual Studio 2008 first following the installation instructions If you use Windows EC 7 Download these two Updates in addition Visual Studio 2008 update for Windows Embedded Compact 7 and Windows Embedded Compact 7 ATL Update for Visual Studio 2008 SP1 Download it from ...

Page 16: ... Elektronik GmbH 16 37 info christ elektronik de www christ elektronik de Tel 49 8331 8371 0 Make sure that NET Framework 3 5 is selected Accept with OK Select destination platform SDK2wince7 Select template console application Accept with OK ...

Page 17: ...h it CE n Console WriteLine from Christ Elektronik GmbH Console ReadLine 6 Debug your code and select the destination SDK2wince7 ARMV7 Device On the Touch it CE Panel should appear a console application 3 3 Flash Memory Layout The Touch it CE has an on board Flash memory 512 MB Tegra T20 This Flash memory is divid ed as follows Description Tegra T20 Bootloader 4096 KB ConfigBlock 3076 KB Image 100...

Page 18: ...elektronik de Tel 49 8331 8371 0 3 4 Permanent Storage Permanent data can be stored in the Touch it CE in three different areas Flash Disk SD Card USB HD You can find these 3 storage areas in My Device as seen below INFORMATION SD Card and USB HD will only appear when a SD Card or USB Stick is inserted ...

Page 19: ...uch as the windows folder are in the RAM image and therefore any files copied to or modified inside these folders will be lost after any power fail 3 4 2 MicroSD Card The Touch it CE has an external microSD Card slot for additional permanent storage microSD storage devices will appear under SD Card in My Device Data stored in this device is perma nent and will remain after a power fail 3 4 3 USB H...

Page 20: ...every setting you change will be lost after a power cycle these include settings such as touch calibration taskbar settings and display settings However you can save the registry changes permanently with a small utility included in the Win dows CE image In order to save the registry settings follow the steps below Double click the Update Tool icon Click on the Save Flash Registry button Confirm th...

Page 21: ...date the operating system is to replace the existing bin nb0 file with a new one This can be done via LAN USB SD memory or by a terminal connection through COM1 3 6 1 Image Update via external memory USB SD From Christ Elektronik you can get the files to make an image update Below you find the steps for the update Unzip all the directories AutoRun Autoxsc etc and copy to a USB Stick or microSD car...

Page 22: ...e Touch it CE Panel while the Touch it CE Panel is booting Now you should see the boot loader menu Type in reboot rcm Go to the DeviceManager on your PC A device called APX must appear Click on it and press the Update Driver button Browse on your computer to the usbpc_driver_32_64 folder inside the Tegra OS image folder and install it Now you can confirm the successful driver installation by verif...

Page 23: ...INFORMATION Press the left shift button on your extern keyboard at boot time many times to interrupt the launcher exe The AutoRun folder will not executed 3 8 Adding Files to Desktop or Start Menu AutoCopy Desktop and Start Menu are subfolders in the Windows folder if you add some files there shortcuts they will be lost on next reboot because the folder is only in the RAM based file sys tem There ...

Page 24: ...network 2 Open a Browser on your Desktop PC and go to http touchit or type in the IP address of the Touch it CE Device 3 Type in your password for the user admin i e admin 4 Start Telnet on your Desktop PC a start cmd exe b type telnet c type open TouchIt d Login admin e Password admin If problems occur be sure that Telnet is activated on your Desktop PC 5 Save the registry over Telnet type update...

Page 25: ... your Touch it CE Device over Telnet type start cerdisp2 c h IP address of your Desktop PC 8 Now you can remote control your Touch it CE Device with the remote display tool CeR Host exe You ve got access to the shared folders of the Touch it CE Device a Type in your Desktop PC explorer TouchIt or IP address b Type in User and password c i e open the Flash Disk folder ...

Page 26: ...hoenix Connector MC 1 5 3 ST 3 5 Pin Function Description 1 GND Power Supply GND 2 PE PE 3 VCC Power Supply VCC 4 2 Ethernet Connector Type 10 100 Base TX RJ45 Tab up Pin Function Description 1 ETH_TX_P Transmit Data 2 ETH_TX_N Transmit Data 3 ETH_RX_P Receive Data 4 PE V V only PoE version 5 PE V V only PoE version 6 ETH_RX_N Receive Data 7 PE V V only PoE version 8 PE V V only PoE version ...

Page 27: ...w Signal 3 CAN GND Can Ground Signal 4 n c 5 n c 6 n c 7 n c 8 n c The switch above the CAN Connector enables the termination resistor 120Ω between the CAN High and CAN Low signals 4 4 COM1 RS 232 Type RJ45 Tab up Pin Function Description 1 GND Ground 2 GND Ground 3 n c 4 TxD Transmit Data 5 RxD Receive Data 6 n c 7 RTS Request to Send 8 CTS Clear to Send Position SW2 Description OFF left CAN Term...

Page 28: ...8371 0 4 5 COM1 RS 232 Touch it CE Codesys Type D SUB ST 09 Pin Function Description 1 n c 2 RxD Receive Data 3 TxD Transmit Data 4 n c 5 GND Ground 6 n c 7 RTS Request to Send 8 CTS Clear to Send 9 n c 4 6 COM2 RS 485 Touch it CE Codesys Type MC 1 5 3 G 3 81 Pin Function Description 1 GND Ground 2 B RS 485 Data 3 A RS 485 Data ...

Page 29: ... RS 232 Signals Low Low RS 485 Signals High Low Type RJ45 Tab up Pin Function Description 1 GND Ground 2 GND Ground 3 A RS 485 Data 4 TxD RS 232 Transmit Data 5 RxD RS 232 Receive Data 6 B RS 485 Data 7 n c 8 n c INFORMATION For writing via RS 485 the GPIO_K7 Tegra T20 must be set High and for reading the GPIO must be set Low The switch above the COM2 Connector enables the termination resistor 120...

Page 30: ...a 3 D USB Data 4 GND USB GND INFORMATION The USB Type A Port2 and the USB Mini B are shared ports It s only pos sible to use one of them simultaneously 4 9 USB Mini Type B Extern Type MINI USB SMT TYPE AB 5 CONTACTS Pin Function Description 1 VBUS USB VCC 2 D USB Data 3 D USB Data 4 N C 5 GND USB GND INFORMATION The USB Type A Port2 and the USB Mini B are shared ports It s only pos sible to use on...

Page 31: ... de Tel 49 8331 8371 0 4 10 Connector Type Mini Sub D BU HD15 The VGA interface is equal with the standard VGA pin assignment 4 11 MircoSD Type DM3AT SF PEJ Pin Function Description 1 D2 SD MMC Data 2 2 D3 CD SD MMC Data 3 3 CMD SD MMC Command 4 3 3V 5 CLK SD MMC Clock 6 GND 7 D0 SD MMC Data 0 8 D1 SD MMC Data 1 ...

Page 32: ...ound 3 In_4 Input 4 4 Out_4V Output 4 5 In_3 Input 3 6 Out_3 Output 3 7 In_2 Input 2 8 Out_2 Output 2 9 In_1 Input 1 10 Out_1 Output 1 INFORMATION The digital input and output signals are isolated from the internal signals Therefore external power of 24V DC and external GND are needed INFORMATION For controlling the digital inputs and outputs are following GPIO used Function GPIO Tegra 2 IN_1 GPIO...

Page 33: ...ous situation Not observing this pointer can cause minor injuries or lead to material damages INFORMATION Denotes application pointers and other useful information 5 2General pointers INFORMATION This device was manufactured according to DIN EN ISO 9001 and left the factory in a perfect state In order to maintain this state and to assure the safe operation the user must consider the pointers and w...

Page 34: ... for use which pose fatal risks and dangers that may cause death injuries serious physi cal impairments or other loss if no exceptional security measures are en sured Thus there are limitations for use in the monitoring of nuclear reac tions in nuclear power plants flight control systems air traffic control in the control of mass transportation medical life support systems and control of weapon sy...

Page 35: ...ser may be required to take adequate measures INFORMATION Please check immediately Is the device damaged or is any equipment missing See chapter Commissioning In the case of defect please inform us immediately 5 4 Maintenance plan INFORMATION Only the manufacturer Christ Elektronik GmbH is allowed to replace the internal lithium battery The calibration of the analog resistive touch may be required...

Page 36: ...elektronik de Tel 49 8331 8371 0 5 6 Cleaning DANGER Disconnect the Touch it Panel PC from the supply voltage before cleaning CAUTION Do not clean the touch sensitive surface of the monitor with detergents con taining solvent or acid INFORMATION Use a humid and soft cloth with gentle soapsuds to clean ...

Page 37: ...hrist Elektronik GmbH Alpenstraße 34 D 87700 Memmingen Tel 49 0 8331 8371 0 Website http www christ elektronik de Copyrights All rights reserved including intel lectual property rights Changes to technical data reserved Delivery subject to availability Copyright Christ Elektronik GmbH Disclaimer Technical data are subject to modi fication and delivery subject to availability Any liability that the...