V2.0W1                                                                                                                                                                  WRIST PULSE OXIMETER 

                                                                                                 

1.1 Know your unit  

 

Picture 1 
 

Summary of Contents for MD300W

Page 1: ...WRIST PULSE OXIMETER INSTRUCTION MANUAL Edition V2 0W1 ...

Page 2: ...access to this manual may not copy use or disclose the information in this work unless expressly authorized by our company to do so All information contained in this manual is believed to be correct Our company shall not be liable for errors contained herein nor for incidental or consequential damages in connection with the furnishing performance or use of this material This publication may refer ...

Page 3: ...ce imaging MRI environment z Explosion Hazard Do not use the Wrist Oximeter in an explosive atmosphere or in the presence of flammable anesthetics or gasses Warnings z The wrist Oximeter is intended only as an adjunct in patient assessment It must be used in conjunction with other methods of assessing clinical signs and symptoms z General operation of the Wrist Oximeter might be affected by the pr...

Page 4: ...th the patient connected to such medical electrical equipment as a cardiac pacemaker and other electrical stimulators And keep away from MRI CT etc It may cause burning and adversely affect MRI measurement z SpO2 measurements may be adversely affected in the presence of high ambient light Shield the sensor area with a surgical towel or direct sunlight for example if necessary z The device should n...

Page 5: ...al z Do not remove any covers other than the battery cover when replacing batteries There are no user serviceable parts inside z Batteries might leak or explode if used or disposed of improper Disposed of the used batteries according to the applicable local regulations z Follow local governing ordinances and recycling instructions regarding disposal or recycling of the device and device components...

Page 6: ...z This device has not been tested for immunity to electromagnetic disturbances z Some nail polish color or artificial nails can reduce light transmission and affect SpO2 accuracy Warning DO NOT use the wrist oximeter when the alarms are required Unpacking and inspecting the wrist oximeter Contact the carrier immediately if the shipping carton for the wrist oximeter is damaged Confirm that the item...

Page 7: ...eral Description 8 2 Inserting and Replacing the Batteries 11 3 Setting up the Wrist Oximeter and Attaching the Sensor 12 4 Measurement 19 5 Specifications 20 6 Error code 22 7 Key symbols 23 8 Maintenance and storage 23 9 Warranty and Repair 24 ...

Page 8: ...and or data collection and recording of adult and pediatric patients in hospitals medial facilities ambulatory subacute and sleepy study environments Scope of application OSAS obstructive sleep apnea syndrome patients Outdoor sportsman Best solution to SIDS sudden infant death syndrome Fire fighter Military Pilot collier Subhealth The function of this new type unit includes SpO2 PR oximetering fin...

Page 9: ...V2 0W1 WRIST PULSE OXIMETER 9 1 1 Know your unit Picture 1 ...

Page 10: ...setting button press this button for a long time you can turn on or turn off the unit under setting menu press this button for a short time you can set the data Low battery voltage Sensor Data Transfer interface 1 2 Product Features Exquisite compact light design Displaying recording SpO2 PR rate USB interface for data transfer Wearing around wrist very compact design easy to carry on hand a weigh...

Page 11: ... position the battery cover Do not force the cover into place it fits only when positioned properly 5 If the wrist oximeter dose not turn on when you press the power on button reinsert the battery or refer to Troubleshooting Note z The battery indicator will begin to appear when the voltage is too low please replace the battery in time z The Wrist Oximeter contains non volatile memory so removing ...

Page 12: ...s on the rear of the Wrist Oximeter As illustrated above the spring bar near the top of the Wrist Oximeter should be threaded first 2 Continue threading the wrist strap until it is pulled securely through both spring bars on the rear of the Wrist Oximeter 3 Press the long segment of the wrist strap securely against the already threaded strap The Wrist Oximeter is now securely mounted on the wrist ...

Page 13: ...of the Wrist Oximeter ensuring that the sensor is plugged correctly and firmly refers to picture 8 Pic 8 NOTE Do NOT insert the sensor incorrectly otherwise there is no SpO2 signal 6 Place the patient s finger inside the sensor Refer to the respective sensor instructions for specific information about placement and patient safety shown as picture 9 Pic 9 ...

Page 14: ...nds to start up the unit Pic 10 Pic 11 The display panel will be high light for self diagnoses when powered on And then the next screen will display the version of the software shown in Pic 11 If there is no probe inserted after power on the following information will appear shown as Pic 12 If the probe is inserted into the oximeter but no finger the information will be shown as Pic 13 Pic 12 Pic ...

Page 15: ... to enter into the parameter setting screen And then press the button for one second repeatedly the parameter will display as following order ID Y year No month d date H hour N1 minute S seconds Press the to set the correct number 3 2 2 1 Year setting Press the button for about three seconds to enter into the parameter setting screen And then press the button for one second repeatedly to enter int...

Page 16: ...ter into the date setting screen or press the button for about three seconds to return to the measuring screen Pic 16 3 2 2 3 Data setting After finish setting the month press the button for about one second to enter into the date setting screen shown as Pic 17 and then press the button to set the right date The setting range is 1 31 And then press the button for about one second to enter into the...

Page 17: ...to the minute setting screen or press the button for about three seconds to return to the measuring screen Pic 18 3 2 2 5 Minute setting After finish setting the hour press the button for about one second to enter into the minute setting screen shown as Pic 19 and then press the button to set the right minute The setting range is 0 59 And then press the button for about one second to enter into th...

Page 18: ...the second setting screen shown as Pic 20 and then press the button to set the right minute The setting range is 0 59 And then press the button for about one second to enter into the minute setting screen or press the button for about three seconds to return to the measuring screen After setting parameter you can measure the SpO2 PR Pic 20 ...

Page 19: ...ructions for specific information about placement and patient safety The signal searching picture is shown as Pic 22 2 The measuring result shown as Pic 23 Description of picture 23 The SpO2 value is 89 and the PR value is 68bpm NOTE Inaccurate measurement can be caused by z Incorrect application of the sensor z Placement of the sensor on an extremity with a blood pressure cuff arterial catheter o...

Page 20: ...aying range 0 254bpm Measuring range 30 235bpm Measuring accurate 30 100 2bpm 101 235bpm 2 5 2 Operating conditions Operating temperature 5 40 Relative humidity 80 Atmosphere pressure 86kPa 106kPa Power supply DC 1 5V Battery One AAA alkaline battery Continuous measurement time Twelve hours 5 3 Package Storage conditions Operating temperature 20 50 Relative humidity 93 ...

Page 21: ...h the computer by the data cable then you can transmit data saved in the oximeter to the computer through the transmission software refers to the transmission software s manual 5 7 Indication function z Battery power indication When the power less than 1 2V The low remaining power indication light will be lighted when the remaining power less than 1 1V the unit will power off itself automatically ...

Page 22: ...e error code of the happened malfunction will be displayed Refer to the following table Error code Malfunction phenomenon E1 Malfunction of SpO2 mode can not measure usually E2 Failure to store or read data but can enter into normal state E13 Low battery voltage Note Please DO NOT repair or disassemble the unit when the error code appear Please connect to our service department in time Pic 25 Pic ...

Page 23: ...rage 1 Remove the battery if you not to use it for long time 2 Clean the wrist oximeter separately from its associated sensors 3 Clean the wrist oximeter with a soft cloth dampened with isopropyl alcohol Do not pour or spray any liquids onto the wrist oximeter and do not allow any liquid to enter any openings in the device Allow the wrist oximeter to dry thoroughly before reusing 4 Store the wrist...

Page 24: ...fied c Update the system software free of charge 9 2 Exempt and limitation a Our company isn t responsible for such damage caused by force majeure For example fire thunder flash flood cyclone hail earthquake house collapse commotion plane failing and traffic accident deliberate damage lack of fuel or water labor and capital bother strike and stop working etc b No service offer The corresponding ch...

Page 25: ...any is entitled to stop contract 9 3 User Guarantee a Please read user manual carefully before operation b Please operate and make daily maintenance as request of manual and guarantee c Power supply and environment 9 4 No guarantee principle There is no dispelled smut and not original mark in the crust There is physical damage on oximeter and its accessory There are liquid leftover and eyewinker o...

Page 26: ...e regulate the guarantee time of host board is one year and all the accessories are six months If users request the guarantee time beyond our regulated guarantee time we should take it into consideration Return Policy Any material to be serviced or returned to our company the following procedures should be followed 1 Obtain return authorization 2 Contact the Technical Support Department and obtain...

Page 27: ... the customer 2 After Warranty The customer is responsible for any freight insurance charges for returned product 9 6 Repackage Take all the accessories and put them into plastic cover Try to use original package and packing material User will be responsible for such damage caused by bad package during transportation Please offer guarantee list and copy of invoice to standby with the period of gua...